Experimental evaluation of pencil beam algorithm by measurements of dose distributions of protons traversing an L-shaped phantom

R. Kohno, Y. Takada, T. Sakae, Akihiro Nohtomi, T. Terunuma, K. Yasuoka

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

A proton dose-calculation method has been developed on the basis of the pencil-beam algorithm (PBA), which is expected to improve the precision of the conventional method based on the broad-beam algorithm (BBA). In order to verify the accuracy of calculation by the PBA, dose distributions formed by a horizontal proton beam traversing a phantom with an L-shaped horizontal cross section were measured using a silicon semiconductor detector (SSD) in a water vessel. The results of the measured dose distributions agree well with the ones calculated using the PBA within an rms error of 2.3%. Therefore, the dose-calculation method by the PBA is useful and applicable to actual treatment planning of the proton therapy.

Original languageEnglish
Pages (from-to)441-445
Number of pages5
JournalJapanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers
Volume40
Issue number1
DOIs
Publication statusPublished - Jan 1 2001
Externally publishedYes

Fingerprint

pencil beams
Protons
dosage
protons
evaluation
Semiconductor detectors
Silicon detectors
Proton beams
proton beams
vessels
planning
therapy
Planning
detectors
cross sections
silicon
water
Water

All Science Journal Classification (ASJC) codes

  • Engineering(all)
  • Physics and Astronomy(all)

Cite this

Experimental evaluation of pencil beam algorithm by measurements of dose distributions of protons traversing an L-shaped phantom. / Kohno, R.; Takada, Y.; Sakae, T.; Nohtomi, Akihiro; Terunuma, T.; Yasuoka, K.

In: Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, Vol. 40, No. 1, 01.01.2001, p. 441-445.

Research output: Contribution to journalArticle

@article{36b5ed7c1bdb47899f4ec311ce19344c,
title = "Experimental evaluation of pencil beam algorithm by measurements of dose distributions of protons traversing an L-shaped phantom",
abstract = "A proton dose-calculation method has been developed on the basis of the pencil-beam algorithm (PBA), which is expected to improve the precision of the conventional method based on the broad-beam algorithm (BBA). In order to verify the accuracy of calculation by the PBA, dose distributions formed by a horizontal proton beam traversing a phantom with an L-shaped horizontal cross section were measured using a silicon semiconductor detector (SSD) in a water vessel. The results of the measured dose distributions agree well with the ones calculated using the PBA within an rms error of 2.3{\%}. Therefore, the dose-calculation method by the PBA is useful and applicable to actual treatment planning of the proton therapy.",
author = "R. Kohno and Y. Takada and T. Sakae and Akihiro Nohtomi and T. Terunuma and K. Yasuoka",
year = "2001",
month = "1",
day = "1",
doi = "10.1143/JJAP.40.441",
language = "English",
volume = "40",
pages = "441--445",
journal = "Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes",
issn = "0021-4922",
publisher = "Institute of Physics",
number = "1",

}

TY - JOUR

T1 - Experimental evaluation of pencil beam algorithm by measurements of dose distributions of protons traversing an L-shaped phantom

AU - Kohno, R.

AU - Takada, Y.

AU - Sakae, T.

AU - Nohtomi, Akihiro

AU - Terunuma, T.

AU - Yasuoka, K.

PY - 2001/1/1

Y1 - 2001/1/1

N2 - A proton dose-calculation method has been developed on the basis of the pencil-beam algorithm (PBA), which is expected to improve the precision of the conventional method based on the broad-beam algorithm (BBA). In order to verify the accuracy of calculation by the PBA, dose distributions formed by a horizontal proton beam traversing a phantom with an L-shaped horizontal cross section were measured using a silicon semiconductor detector (SSD) in a water vessel. The results of the measured dose distributions agree well with the ones calculated using the PBA within an rms error of 2.3%. Therefore, the dose-calculation method by the PBA is useful and applicable to actual treatment planning of the proton therapy.

AB - A proton dose-calculation method has been developed on the basis of the pencil-beam algorithm (PBA), which is expected to improve the precision of the conventional method based on the broad-beam algorithm (BBA). In order to verify the accuracy of calculation by the PBA, dose distributions formed by a horizontal proton beam traversing a phantom with an L-shaped horizontal cross section were measured using a silicon semiconductor detector (SSD) in a water vessel. The results of the measured dose distributions agree well with the ones calculated using the PBA within an rms error of 2.3%. Therefore, the dose-calculation method by the PBA is useful and applicable to actual treatment planning of the proton therapy.

UR - http://www.scopus.com/inward/record.url?scp=0035064921&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035064921&partnerID=8YFLogxK

U2 - 10.1143/JJAP.40.441

DO - 10.1143/JJAP.40.441

M3 - Article

AN - SCOPUS:0035064921

VL - 40

SP - 441

EP - 445

JO - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes

JF - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes

SN - 0021-4922

IS - 1

ER -