Experimental study of cavitation induced oscillation in helical inducer with various blade lengths

Akinori Furukawa, Koichi Ishizaka, Satoshi Watanabe

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Cavitation tests have been carried out for helical inducer with various blade lengths. Effects of inducer blade lengths on head characteristics and cavitation induced oscillation phenomena are described in the present paper. The oscillation occurring in the case of inducers with lower solidity less than 1.0 differs from that with the solidity of 2.0. Change of the flow distributions during the oscillation is measured from by using a single hole yawmcter with the phase locked sampling method to the oscillation. By compared with the results for higher solidity inducer, the behaviors of cavitation induced oscillation are clarified.

Original languageEnglish
Pages (from-to)2425-2430
Number of pages6
JournalNihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
Volume67
Issue number662
DOIs
Publication statusPublished - Oct 2001
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Condensed Matter Physics
  • Mechanical Engineering

Fingerprint Dive into the research topics of 'Experimental study of cavitation induced oscillation in helical inducer with various blade lengths'. Together they form a unique fingerprint.