Experimental study on displacement and strain distributions of bone model with dental implant

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

For normal healthy teeth, the percussive energy generated by mastication is attenuated by the periodontal ligament at the healthy bone/natural tooth interface. However, when a natural tooth must be replaced by an implant because of damage or disease, the ligament is lost and the implant will transmit the percussive forces to the bone directly. Studies have evaluated the deformation distribution of the alveolar bone in the vicinity of implants using finite element analysis and photoelasticity. However, finite element analysis requires clinical verification or a determination of material properties, and photoelastic materials generally have material properties and structure quite different from those of actual bone. Therefore, this study examined the deformation distribution around dental implants in cortical/cancellous bone experimentally using sawbone cortical/cancellous bone models. Dental implants were placed in the bone models and the displacement distribution was measured using the digital image correlation method, and the strain distribution was visualized under a compressive load that simulated the occlusion force.

Original languageEnglish
Title of host publicationExperimental Mechanics and Materials
Pages73-77
Number of pages5
DOIs
Publication statusPublished - Sep 1 2011
EventInternational Conference on Experimental Mechanics 2010, ICEM10 - Kuala Lumpur, Malaysia
Duration: Nov 29 2010Dec 1 2010

Publication series

NameApplied Mechanics and Materials
Volume83
ISSN (Print)1660-9336
ISSN (Electronic)1662-7482

Other

OtherInternational Conference on Experimental Mechanics 2010, ICEM10
CountryMalaysia
CityKuala Lumpur
Period11/29/1012/1/10

Fingerprint

Dental prostheses
Bone
Ligaments
Materials properties
Mastication
Finite element method
Photoelasticity
Correlation methods
Loads (forces)

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Experimental study on displacement and strain distributions of bone model with dental implant. / Morita, Yasuyuki; Matsushita, Yasuyuki; Todo, Mitsugu; Koyano, Kiyoshi.

Experimental Mechanics and Materials. 2011. p. 73-77 (Applied Mechanics and Materials; Vol. 83).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Morita, Y, Matsushita, Y, Todo, M & Koyano, K 2011, Experimental study on displacement and strain distributions of bone model with dental implant. in Experimental Mechanics and Materials. Applied Mechanics and Materials, vol. 83, pp. 73-77, International Conference on Experimental Mechanics 2010, ICEM10, Kuala Lumpur, Malaysia, 11/29/10. https://doi.org/10.4028/www.scientific.net/AMM.83.73
Morita, Yasuyuki ; Matsushita, Yasuyuki ; Todo, Mitsugu ; Koyano, Kiyoshi. / Experimental study on displacement and strain distributions of bone model with dental implant. Experimental Mechanics and Materials. 2011. pp. 73-77 (Applied Mechanics and Materials).
@inproceedings{420855f188104a03ad953ff6b3753b25,
title = "Experimental study on displacement and strain distributions of bone model with dental implant",
abstract = "For normal healthy teeth, the percussive energy generated by mastication is attenuated by the periodontal ligament at the healthy bone/natural tooth interface. However, when a natural tooth must be replaced by an implant because of damage or disease, the ligament is lost and the implant will transmit the percussive forces to the bone directly. Studies have evaluated the deformation distribution of the alveolar bone in the vicinity of implants using finite element analysis and photoelasticity. However, finite element analysis requires clinical verification or a determination of material properties, and photoelastic materials generally have material properties and structure quite different from those of actual bone. Therefore, this study examined the deformation distribution around dental implants in cortical/cancellous bone experimentally using sawbone cortical/cancellous bone models. Dental implants were placed in the bone models and the displacement distribution was measured using the digital image correlation method, and the strain distribution was visualized under a compressive load that simulated the occlusion force.",
author = "Yasuyuki Morita and Yasuyuki Matsushita and Mitsugu Todo and Kiyoshi Koyano",
year = "2011",
month = "9",
day = "1",
doi = "10.4028/www.scientific.net/AMM.83.73",
language = "English",
isbn = "9783037852217",
series = "Applied Mechanics and Materials",
pages = "73--77",
booktitle = "Experimental Mechanics and Materials",

}

TY - GEN

T1 - Experimental study on displacement and strain distributions of bone model with dental implant

AU - Morita, Yasuyuki

AU - Matsushita, Yasuyuki

AU - Todo, Mitsugu

AU - Koyano, Kiyoshi

PY - 2011/9/1

Y1 - 2011/9/1

N2 - For normal healthy teeth, the percussive energy generated by mastication is attenuated by the periodontal ligament at the healthy bone/natural tooth interface. However, when a natural tooth must be replaced by an implant because of damage or disease, the ligament is lost and the implant will transmit the percussive forces to the bone directly. Studies have evaluated the deformation distribution of the alveolar bone in the vicinity of implants using finite element analysis and photoelasticity. However, finite element analysis requires clinical verification or a determination of material properties, and photoelastic materials generally have material properties and structure quite different from those of actual bone. Therefore, this study examined the deformation distribution around dental implants in cortical/cancellous bone experimentally using sawbone cortical/cancellous bone models. Dental implants were placed in the bone models and the displacement distribution was measured using the digital image correlation method, and the strain distribution was visualized under a compressive load that simulated the occlusion force.

AB - For normal healthy teeth, the percussive energy generated by mastication is attenuated by the periodontal ligament at the healthy bone/natural tooth interface. However, when a natural tooth must be replaced by an implant because of damage or disease, the ligament is lost and the implant will transmit the percussive forces to the bone directly. Studies have evaluated the deformation distribution of the alveolar bone in the vicinity of implants using finite element analysis and photoelasticity. However, finite element analysis requires clinical verification or a determination of material properties, and photoelastic materials generally have material properties and structure quite different from those of actual bone. Therefore, this study examined the deformation distribution around dental implants in cortical/cancellous bone experimentally using sawbone cortical/cancellous bone models. Dental implants were placed in the bone models and the displacement distribution was measured using the digital image correlation method, and the strain distribution was visualized under a compressive load that simulated the occlusion force.

UR - http://www.scopus.com/inward/record.url?scp=80052106507&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80052106507&partnerID=8YFLogxK

U2 - 10.4028/www.scientific.net/AMM.83.73

DO - 10.4028/www.scientific.net/AMM.83.73

M3 - Conference contribution

SN - 9783037852217

T3 - Applied Mechanics and Materials

SP - 73

EP - 77

BT - Experimental Mechanics and Materials

ER -