Fabrication of fork-shaped retinal stimulator integrated with CMOS microchips for extension of viewing angle

Toshihiko Noda, Kiyotaka Sasagawa, Takashi Tokuda, Hiroyuki Kanda, Yasuo Terasawa, Hiroyuki Tashiro, Takashi Fujikado, Jun Ohta

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

A fork-shaped retinal stimulator for a wide viewing angle was fabricated and demonstrated. This stimulator has two flexible fork elements, each with a stimulus head. The two fork elements can be implanted at different places in the eyeball to cover a wider area of the retina. The stimulus head has stimulus electrodes with the same shape as the electrodes utilized in a clinical trial for six weeks. Complementary metal-oxide semiconductor (CMOS) microchips were integrated into the stimulator and mounted next to the stimulus electrodes. Since stimulus current generators are integrated into the microchips, no external wires for stimulus current are required. A multiplexer, which reduces the number of wirings, was also integrated into the microchips. The fabricated stimulator was evaluated through in vivo animal experiments. The stimulator was successfully implanted in two places of the eyeball. Retinal stimulation by the device evoked nerve responses from optic chiasma and produced a specific peak of evoked potential. Experimental results demonstrate the proof of concept of a fork-shaped stimulator and suggest that the same device configuration can realize multiple forkshaped stimulators for a wider viewing angle. Moreover, increasing the number of fork elements of the multifork stimulator without additional wirings becomes possible.

Original languageEnglish
Pages (from-to)637-648
Number of pages12
JournalSensors and Materials
Volume26
Issue number8
Publication statusPublished - Jan 1 2014

Fingerprint

forks
stimuli
CMOS
Metals
Electric wiring
Fabrication
Electrodes
fabrication
wiring
Bioelectric potentials
electrodes
Optics
Animals
Wire
retina
nerves
stimulation
animals
Oxide semiconductors
generators

All Science Journal Classification (ASJC) codes

  • Instrumentation
  • Materials Science(all)

Cite this

Noda, T., Sasagawa, K., Tokuda, T., Kanda, H., Terasawa, Y., Tashiro, H., ... Ohta, J. (2014). Fabrication of fork-shaped retinal stimulator integrated with CMOS microchips for extension of viewing angle. Sensors and Materials, 26(8), 637-648.

Fabrication of fork-shaped retinal stimulator integrated with CMOS microchips for extension of viewing angle. / Noda, Toshihiko; Sasagawa, Kiyotaka; Tokuda, Takashi; Kanda, Hiroyuki; Terasawa, Yasuo; Tashiro, Hiroyuki; Fujikado, Takashi; Ohta, Jun.

In: Sensors and Materials, Vol. 26, No. 8, 01.01.2014, p. 637-648.

Research output: Contribution to journalArticle

Noda, T, Sasagawa, K, Tokuda, T, Kanda, H, Terasawa, Y, Tashiro, H, Fujikado, T & Ohta, J 2014, 'Fabrication of fork-shaped retinal stimulator integrated with CMOS microchips for extension of viewing angle', Sensors and Materials, vol. 26, no. 8, pp. 637-648.
Noda, Toshihiko ; Sasagawa, Kiyotaka ; Tokuda, Takashi ; Kanda, Hiroyuki ; Terasawa, Yasuo ; Tashiro, Hiroyuki ; Fujikado, Takashi ; Ohta, Jun. / Fabrication of fork-shaped retinal stimulator integrated with CMOS microchips for extension of viewing angle. In: Sensors and Materials. 2014 ; Vol. 26, No. 8. pp. 637-648.
@article{4914f7f660df495c9bf731645db32460,
title = "Fabrication of fork-shaped retinal stimulator integrated with CMOS microchips for extension of viewing angle",
abstract = "A fork-shaped retinal stimulator for a wide viewing angle was fabricated and demonstrated. This stimulator has two flexible fork elements, each with a stimulus head. The two fork elements can be implanted at different places in the eyeball to cover a wider area of the retina. The stimulus head has stimulus electrodes with the same shape as the electrodes utilized in a clinical trial for six weeks. Complementary metal-oxide semiconductor (CMOS) microchips were integrated into the stimulator and mounted next to the stimulus electrodes. Since stimulus current generators are integrated into the microchips, no external wires for stimulus current are required. A multiplexer, which reduces the number of wirings, was also integrated into the microchips. The fabricated stimulator was evaluated through in vivo animal experiments. The stimulator was successfully implanted in two places of the eyeball. Retinal stimulation by the device evoked nerve responses from optic chiasma and produced a specific peak of evoked potential. Experimental results demonstrate the proof of concept of a fork-shaped stimulator and suggest that the same device configuration can realize multiple forkshaped stimulators for a wider viewing angle. Moreover, increasing the number of fork elements of the multifork stimulator without additional wirings becomes possible.",
author = "Toshihiko Noda and Kiyotaka Sasagawa and Takashi Tokuda and Hiroyuki Kanda and Yasuo Terasawa and Hiroyuki Tashiro and Takashi Fujikado and Jun Ohta",
year = "2014",
month = "1",
day = "1",
language = "English",
volume = "26",
pages = "637--648",
journal = "Sensors and Materials",
issn = "0914-4935",
publisher = "M Y U Scientific Publishing Division",
number = "8",

}

TY - JOUR

T1 - Fabrication of fork-shaped retinal stimulator integrated with CMOS microchips for extension of viewing angle

AU - Noda, Toshihiko

AU - Sasagawa, Kiyotaka

AU - Tokuda, Takashi

AU - Kanda, Hiroyuki

AU - Terasawa, Yasuo

AU - Tashiro, Hiroyuki

AU - Fujikado, Takashi

AU - Ohta, Jun

PY - 2014/1/1

Y1 - 2014/1/1

N2 - A fork-shaped retinal stimulator for a wide viewing angle was fabricated and demonstrated. This stimulator has two flexible fork elements, each with a stimulus head. The two fork elements can be implanted at different places in the eyeball to cover a wider area of the retina. The stimulus head has stimulus electrodes with the same shape as the electrodes utilized in a clinical trial for six weeks. Complementary metal-oxide semiconductor (CMOS) microchips were integrated into the stimulator and mounted next to the stimulus electrodes. Since stimulus current generators are integrated into the microchips, no external wires for stimulus current are required. A multiplexer, which reduces the number of wirings, was also integrated into the microchips. The fabricated stimulator was evaluated through in vivo animal experiments. The stimulator was successfully implanted in two places of the eyeball. Retinal stimulation by the device evoked nerve responses from optic chiasma and produced a specific peak of evoked potential. Experimental results demonstrate the proof of concept of a fork-shaped stimulator and suggest that the same device configuration can realize multiple forkshaped stimulators for a wider viewing angle. Moreover, increasing the number of fork elements of the multifork stimulator without additional wirings becomes possible.

AB - A fork-shaped retinal stimulator for a wide viewing angle was fabricated and demonstrated. This stimulator has two flexible fork elements, each with a stimulus head. The two fork elements can be implanted at different places in the eyeball to cover a wider area of the retina. The stimulus head has stimulus electrodes with the same shape as the electrodes utilized in a clinical trial for six weeks. Complementary metal-oxide semiconductor (CMOS) microchips were integrated into the stimulator and mounted next to the stimulus electrodes. Since stimulus current generators are integrated into the microchips, no external wires for stimulus current are required. A multiplexer, which reduces the number of wirings, was also integrated into the microchips. The fabricated stimulator was evaluated through in vivo animal experiments. The stimulator was successfully implanted in two places of the eyeball. Retinal stimulation by the device evoked nerve responses from optic chiasma and produced a specific peak of evoked potential. Experimental results demonstrate the proof of concept of a fork-shaped stimulator and suggest that the same device configuration can realize multiple forkshaped stimulators for a wider viewing angle. Moreover, increasing the number of fork elements of the multifork stimulator without additional wirings becomes possible.

UR - http://www.scopus.com/inward/record.url?scp=84913542781&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84913542781&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84913542781

VL - 26

SP - 637

EP - 648

JO - Sensors and Materials

JF - Sensors and Materials

SN - 0914-4935

IS - 8

ER -