Flash cycle optimization of Sabalan geothermal power plant employing exergy concept

Saeid Jalilinasrabady, Ryuichi Itoi, Pall Valdimarsson, Gudrun Saevarsdottir, Hikari Fujii

Research output: Contribution to journalArticle

55 Citations (Scopus)

Abstract

The Sabalan geothermal field in northwest Iran is currently under development. A single flash cycle has been selected for power generation. The analysis of the proposed design shows the maximum net power output of the plant can reach 31. MW if the pressures of the separator and condenser are 5.5 and 0.3. bar, respectively. To achieve optimum energy utilization, a double flash cycle was also evaluated for power generation. The results indicate the maximum net power output of the plant reaches 49.7. MW if the pressures for the high- and low-pressure steps and condenser are 7.5, 1.1, and 0.1. bar, respectively. Mathematical models for energy and exergy flows were developed and implemented in Engineering Equation Solver (EES) software. In the single flash cycle, the energy and exergy of the waste water were calculated as 54.8% and 41.4% of the total available energy and exergy, respectively. The energy and exergy of waste water were respectively calculated as 19.88% and 15.3% of the total available energy and exergy, in the double flash cycle. The parts of the system with largest exergy destruction in both cycles were compared and the overall exergy and energy efficiencies for the power plant were calculated. The total exergy available from production wells at Sabalan was calculated to be 111. MW for the single flash system, and 114. MW for the double flash system. The results of the analysis suggest a double flash cycle system for the Sabalan power plant.

Original languageEnglish
Pages (from-to)75-82
Number of pages8
JournalGeothermics
Volume43
DOIs
Publication statusPublished - Jul 1 2012

Fingerprint

Geothermal power plants
geothermal power
exergy
Exergy
power plant
energy
power generation
Power generation
Power plants
Wastewater
Geothermal fields
Separators
energy efficiency
Energy efficiency
low pressure
Energy utilization
Mathematical models
software
well
engineering

All Science Journal Classification (ASJC) codes

  • Renewable Energy, Sustainability and the Environment
  • Geotechnical Engineering and Engineering Geology
  • Geology

Cite this

Flash cycle optimization of Sabalan geothermal power plant employing exergy concept. / Jalilinasrabady, Saeid; Itoi, Ryuichi; Valdimarsson, Pall; Saevarsdottir, Gudrun; Fujii, Hikari.

In: Geothermics, Vol. 43, 01.07.2012, p. 75-82.

Research output: Contribution to journalArticle

Jalilinasrabady, Saeid ; Itoi, Ryuichi ; Valdimarsson, Pall ; Saevarsdottir, Gudrun ; Fujii, Hikari. / Flash cycle optimization of Sabalan geothermal power plant employing exergy concept. In: Geothermics. 2012 ; Vol. 43. pp. 75-82.
@article{5579962d91b04f64b23de4f46a5d6882,
title = "Flash cycle optimization of Sabalan geothermal power plant employing exergy concept",
abstract = "The Sabalan geothermal field in northwest Iran is currently under development. A single flash cycle has been selected for power generation. The analysis of the proposed design shows the maximum net power output of the plant can reach 31. MW if the pressures of the separator and condenser are 5.5 and 0.3. bar, respectively. To achieve optimum energy utilization, a double flash cycle was also evaluated for power generation. The results indicate the maximum net power output of the plant reaches 49.7. MW if the pressures for the high- and low-pressure steps and condenser are 7.5, 1.1, and 0.1. bar, respectively. Mathematical models for energy and exergy flows were developed and implemented in Engineering Equation Solver (EES) software. In the single flash cycle, the energy and exergy of the waste water were calculated as 54.8{\%} and 41.4{\%} of the total available energy and exergy, respectively. The energy and exergy of waste water were respectively calculated as 19.88{\%} and 15.3{\%} of the total available energy and exergy, in the double flash cycle. The parts of the system with largest exergy destruction in both cycles were compared and the overall exergy and energy efficiencies for the power plant were calculated. The total exergy available from production wells at Sabalan was calculated to be 111. MW for the single flash system, and 114. MW for the double flash system. The results of the analysis suggest a double flash cycle system for the Sabalan power plant.",
author = "Saeid Jalilinasrabady and Ryuichi Itoi and Pall Valdimarsson and Gudrun Saevarsdottir and Hikari Fujii",
year = "2012",
month = "7",
day = "1",
doi = "10.1016/j.geothermics.2012.02.003",
language = "English",
volume = "43",
pages = "75--82",
journal = "Geothermics",
issn = "0375-6505",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Flash cycle optimization of Sabalan geothermal power plant employing exergy concept

AU - Jalilinasrabady, Saeid

AU - Itoi, Ryuichi

AU - Valdimarsson, Pall

AU - Saevarsdottir, Gudrun

AU - Fujii, Hikari

PY - 2012/7/1

Y1 - 2012/7/1

N2 - The Sabalan geothermal field in northwest Iran is currently under development. A single flash cycle has been selected for power generation. The analysis of the proposed design shows the maximum net power output of the plant can reach 31. MW if the pressures of the separator and condenser are 5.5 and 0.3. bar, respectively. To achieve optimum energy utilization, a double flash cycle was also evaluated for power generation. The results indicate the maximum net power output of the plant reaches 49.7. MW if the pressures for the high- and low-pressure steps and condenser are 7.5, 1.1, and 0.1. bar, respectively. Mathematical models for energy and exergy flows were developed and implemented in Engineering Equation Solver (EES) software. In the single flash cycle, the energy and exergy of the waste water were calculated as 54.8% and 41.4% of the total available energy and exergy, respectively. The energy and exergy of waste water were respectively calculated as 19.88% and 15.3% of the total available energy and exergy, in the double flash cycle. The parts of the system with largest exergy destruction in both cycles were compared and the overall exergy and energy efficiencies for the power plant were calculated. The total exergy available from production wells at Sabalan was calculated to be 111. MW for the single flash system, and 114. MW for the double flash system. The results of the analysis suggest a double flash cycle system for the Sabalan power plant.

AB - The Sabalan geothermal field in northwest Iran is currently under development. A single flash cycle has been selected for power generation. The analysis of the proposed design shows the maximum net power output of the plant can reach 31. MW if the pressures of the separator and condenser are 5.5 and 0.3. bar, respectively. To achieve optimum energy utilization, a double flash cycle was also evaluated for power generation. The results indicate the maximum net power output of the plant reaches 49.7. MW if the pressures for the high- and low-pressure steps and condenser are 7.5, 1.1, and 0.1. bar, respectively. Mathematical models for energy and exergy flows were developed and implemented in Engineering Equation Solver (EES) software. In the single flash cycle, the energy and exergy of the waste water were calculated as 54.8% and 41.4% of the total available energy and exergy, respectively. The energy and exergy of waste water were respectively calculated as 19.88% and 15.3% of the total available energy and exergy, in the double flash cycle. The parts of the system with largest exergy destruction in both cycles were compared and the overall exergy and energy efficiencies for the power plant were calculated. The total exergy available from production wells at Sabalan was calculated to be 111. MW for the single flash system, and 114. MW for the double flash system. The results of the analysis suggest a double flash cycle system for the Sabalan power plant.

UR - http://www.scopus.com/inward/record.url?scp=84861950867&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84861950867&partnerID=8YFLogxK

U2 - 10.1016/j.geothermics.2012.02.003

DO - 10.1016/j.geothermics.2012.02.003

M3 - Article

VL - 43

SP - 75

EP - 82

JO - Geothermics

JF - Geothermics

SN - 0375-6505

ER -