Flow measurement at partial flow rate with LDV around rear rotor of contra-rotating axial flow pump

Shuichi Yamashita, Satoshi Watanabe, Kusuo Okuma, Kyota Shirasawa, Akinori Furukawa

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

An application of contra-rotating rotors, in which a rear rotor is employed in tandem with a front one and these rotors rotate in the opposite direction each other, has been proposed against a demand for developing higher specific speed axial flow pump. The internal flow field of pump should be considered in the design for higher performance and more stable operation. The flow field in contra-rotating axial flow pump was measured with LDV and wall pressure measurements. In the present paper, the experimental results are shown and the flow behaviors would be discussed.

Original languageEnglish
Title of host publication2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007
Pages909-914
Number of pages6
EditionPART B
DOIs
Publication statusPublished - Dec 1 2007
Event2007 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007 - San Diego, CA, United States
Duration: Jul 30 2007Aug 2 2007

Publication series

Name2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007
NumberPART B
Volume2 FORA

Other

Other2007 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007
CountryUnited States
CitySan Diego, CA
Period7/30/078/2/07

Fingerprint

axial flow pumps
Axial flow
flow measurement
Flow measurement
rotors
flow velocity
Rotors
Flow rate
Pumps
Flow fields
flow distribution
internal flow
wall pressure
pressure measurement
Pressure measurement
pumps

All Science Journal Classification (ASJC) codes

  • Mechanical Engineering
  • Condensed Matter Physics

Cite this

Yamashita, S., Watanabe, S., Okuma, K., Shirasawa, K., & Furukawa, A. (2007). Flow measurement at partial flow rate with LDV around rear rotor of contra-rotating axial flow pump. In 2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007 (PART B ed., pp. 909-914). (2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007; Vol. 2 FORA, No. PART B). https://doi.org/10.1115/FEDSM2007-37467

Flow measurement at partial flow rate with LDV around rear rotor of contra-rotating axial flow pump. / Yamashita, Shuichi; Watanabe, Satoshi; Okuma, Kusuo; Shirasawa, Kyota; Furukawa, Akinori.

2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007. PART B. ed. 2007. p. 909-914 (2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007; Vol. 2 FORA, No. PART B).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Yamashita, S, Watanabe, S, Okuma, K, Shirasawa, K & Furukawa, A 2007, Flow measurement at partial flow rate with LDV around rear rotor of contra-rotating axial flow pump. in 2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007. PART B edn, 2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007, no. PART B, vol. 2 FORA, pp. 909-914, 2007 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007, San Diego, CA, United States, 7/30/07. https://doi.org/10.1115/FEDSM2007-37467
Yamashita S, Watanabe S, Okuma K, Shirasawa K, Furukawa A. Flow measurement at partial flow rate with LDV around rear rotor of contra-rotating axial flow pump. In 2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007. PART B ed. 2007. p. 909-914. (2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007; PART B). https://doi.org/10.1115/FEDSM2007-37467
Yamashita, Shuichi ; Watanabe, Satoshi ; Okuma, Kusuo ; Shirasawa, Kyota ; Furukawa, Akinori. / Flow measurement at partial flow rate with LDV around rear rotor of contra-rotating axial flow pump. 2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007. PART B. ed. 2007. pp. 909-914 (2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007; PART B).
@inproceedings{6c48a6b5a5d845429c4fd9b9bcbb2a5e,
title = "Flow measurement at partial flow rate with LDV around rear rotor of contra-rotating axial flow pump",
abstract = "An application of contra-rotating rotors, in which a rear rotor is employed in tandem with a front one and these rotors rotate in the opposite direction each other, has been proposed against a demand for developing higher specific speed axial flow pump. The internal flow field of pump should be considered in the design for higher performance and more stable operation. The flow field in contra-rotating axial flow pump was measured with LDV and wall pressure measurements. In the present paper, the experimental results are shown and the flow behaviors would be discussed.",
author = "Shuichi Yamashita and Satoshi Watanabe and Kusuo Okuma and Kyota Shirasawa and Akinori Furukawa",
year = "2007",
month = "12",
day = "1",
doi = "10.1115/FEDSM2007-37467",
language = "English",
isbn = "0791842886",
series = "2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007",
number = "PART B",
pages = "909--914",
booktitle = "2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007",
edition = "PART B",

}

TY - GEN

T1 - Flow measurement at partial flow rate with LDV around rear rotor of contra-rotating axial flow pump

AU - Yamashita, Shuichi

AU - Watanabe, Satoshi

AU - Okuma, Kusuo

AU - Shirasawa, Kyota

AU - Furukawa, Akinori

PY - 2007/12/1

Y1 - 2007/12/1

N2 - An application of contra-rotating rotors, in which a rear rotor is employed in tandem with a front one and these rotors rotate in the opposite direction each other, has been proposed against a demand for developing higher specific speed axial flow pump. The internal flow field of pump should be considered in the design for higher performance and more stable operation. The flow field in contra-rotating axial flow pump was measured with LDV and wall pressure measurements. In the present paper, the experimental results are shown and the flow behaviors would be discussed.

AB - An application of contra-rotating rotors, in which a rear rotor is employed in tandem with a front one and these rotors rotate in the opposite direction each other, has been proposed against a demand for developing higher specific speed axial flow pump. The internal flow field of pump should be considered in the design for higher performance and more stable operation. The flow field in contra-rotating axial flow pump was measured with LDV and wall pressure measurements. In the present paper, the experimental results are shown and the flow behaviors would be discussed.

UR - http://www.scopus.com/inward/record.url?scp=40549110643&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=40549110643&partnerID=8YFLogxK

U2 - 10.1115/FEDSM2007-37467

DO - 10.1115/FEDSM2007-37467

M3 - Conference contribution

AN - SCOPUS:40549110643

SN - 0791842886

SN - 9780791842881

T3 - 2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007

SP - 909

EP - 914

BT - 2007 Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, FEDSM 2007

ER -