G0210201 遊離端義歯に対するインプラント支持効果の力学的評価(バイオエンジニアリング部門一般セッション(2))

Translated title of the contribution: G0210201 Mechanical efficacy assessment of dental implant support for cantilever partial denture

森田 健敬, 山野 浩之, 澤江 義則, 松下 恭之, 江崎 大輔, 三枝 真依子

Research output: Contribution to journalArticle

Abstract

In this study, an experimental system has been developed to evaluate the efficacy of the implant which is implanted at the first molar position to support the mastication force acting on the cantilever type partial denture and to reduce the mechanical loads suffered by the abutment tooth. By using the established system, the effect of direct connection between the dental implant and the partial denture was examined. Results indicated that the tested implant had a certain effect to reduce the mechanical loadings on the abutment. However, the intense lateral loading on the abutment tooth could not be suppressed sufficiently by only one implant at the first molar position, especially when the mastication force was applied on the denture not only vertically but also laterally.
Original languageJapanese
Pages (from-to)_G0210201--_G0210201-
Journal年次大会
Volume2014
Issue number0
DOIs
Publication statusPublished - 2014

Fingerprint

Partial Denture
Dental Implants
Mastication
Tooth
Dentures

Cite this

G0210201 遊離端義歯に対するインプラント支持効果の力学的評価(バイオエンジニアリング部門一般セッション(2)). / 森田健敬; 山野浩之; 澤江義則; 松下恭之; 江崎大輔; 三枝真依子.

In: 年次大会, Vol. 2014, No. 0, 2014, p. _G0210201--_G0210201-.

Research output: Contribution to journalArticle

@article{5c63dc681e434fc9bd50c14571041bca,
title = "G0210201 遊離端義歯に対するインプラント支持効果の力学的評価(バイオエンジニアリング部門一般セッション(2))",
abstract = "In this study, an experimental system has been developed to evaluate the efficacy of the implant which is implanted at the first molar position to support the mastication force acting on the cantilever type partial denture and to reduce the mechanical loads suffered by the abutment tooth. By using the established system, the effect of direct connection between the dental implant and the partial denture was examined. Results indicated that the tested implant had a certain effect to reduce the mechanical loadings on the abutment. However, the intense lateral loading on the abutment tooth could not be suppressed sufficiently by only one implant at the first molar position, especially when the mastication force was applied on the denture not only vertically but also laterally.",
author = "健敬 森田 and 浩之 山野 and 義則 澤江 and 恭之 松下 and 大輔 江崎 and 真依子 三枝",
year = "2014",
doi = "10.1299/jsmemecj.2014._G0210201-",
language = "Japanese",
volume = "2014",
pages = "_G0210201----_G0210201--",
journal = "年次大会",
publisher = "一般社団法人日本機械学会",
number = "0",

}

TY - JOUR

T1 - G0210201 遊離端義歯に対するインプラント支持効果の力学的評価(バイオエンジニアリング部門一般セッション(2))

AU - 森田, 健敬

AU - 山野, 浩之

AU - 澤江, 義則

AU - 松下, 恭之

AU - 江崎, 大輔

AU - 三枝, 真依子

PY - 2014

Y1 - 2014

N2 - In this study, an experimental system has been developed to evaluate the efficacy of the implant which is implanted at the first molar position to support the mastication force acting on the cantilever type partial denture and to reduce the mechanical loads suffered by the abutment tooth. By using the established system, the effect of direct connection between the dental implant and the partial denture was examined. Results indicated that the tested implant had a certain effect to reduce the mechanical loadings on the abutment. However, the intense lateral loading on the abutment tooth could not be suppressed sufficiently by only one implant at the first molar position, especially when the mastication force was applied on the denture not only vertically but also laterally.

AB - In this study, an experimental system has been developed to evaluate the efficacy of the implant which is implanted at the first molar position to support the mastication force acting on the cantilever type partial denture and to reduce the mechanical loads suffered by the abutment tooth. By using the established system, the effect of direct connection between the dental implant and the partial denture was examined. Results indicated that the tested implant had a certain effect to reduce the mechanical loadings on the abutment. However, the intense lateral loading on the abutment tooth could not be suppressed sufficiently by only one implant at the first molar position, especially when the mastication force was applied on the denture not only vertically but also laterally.

U2 - 10.1299/jsmemecj.2014._G0210201-

DO - 10.1299/jsmemecj.2014._G0210201-

M3 - 記事

VL - 2014

SP - _G0210201--_G0210201-

JO - 年次大会

JF - 年次大会

IS - 0

ER -