T1 - Harmonization of Standardized Uptake Value among Different Generation PET/ CT Cameras Based on a Phantom Experiment -Utility of SUV(peak)
AU - Akamatsu, Go
AU - Nishida, Hiroyuki
AU - Fujino, Akira
AU - Ohnishi, Akihito
AU - Ikari, Yasuhiko
AU - Nishio, Tomoyuki
AU - Maebatake, Akira
AU - Sasaki, Masayuki
AU - Senda, Michio
PY - 2015/9/1
Y1 - 2015/9/1
N2 - Standardized uptake value (SUV) has been widely used as a semi-quantitative metric of uptake in FDGPET/ CT for diagnosis of malignant tumors and evaluation of tumor therapies. However, the SUV depends on various factors including PET/CT scanner specifications and reconstruction parameters. The purpose of this study is to harmonize the SUV among two PET/CT models of different generation: two units of Discovery ST Elite Performance(DSTEP) and Discovery 690 (D690) PET/CT scanners. The NEMA body phantom filled with 18F solution was scanned for 30 minutes in list-mode. The D690 PET images were reconstructed with OSEM, OSEM+TOF, and OSEM+PSF. Gaussian post-filters of 4-9 mm FWHM were applied to find the parameters that provides harmonized SUV. We determined the SUV-harmonized parameter for each reconstruction algorithm. Then, the 10 PET images simulating clinical scan conditions were respectively generated to evaluate the bias and variability of SUV(max) and SUV(peak). The SUV(max) strongly depended not only on spatial resolution but also on image noise. On the other hand, the SUV(peak) was a robust metric to image noise level. TOF improved the variability of SUV(max) and SUV(peak). Thus, we were able to harmonize the spatial resolution using SUV(peak) based on the phantom study. Because SUV(max) was also strongly affected by image noise, sufficient count statistics is essential for SUV(max) harmonization. We recommended that TOF reconstruction and SUV(peak) metric should be used to harmonize SUV.
AB - Standardized uptake value (SUV) has been widely used as a semi-quantitative metric of uptake in FDGPET/ CT for diagnosis of malignant tumors and evaluation of tumor therapies. However, the SUV depends on various factors including PET/CT scanner specifications and reconstruction parameters. The purpose of this study is to harmonize the SUV among two PET/CT models of different generation: two units of Discovery ST Elite Performance(DSTEP) and Discovery 690 (D690) PET/CT scanners. The NEMA body phantom filled with 18F solution was scanned for 30 minutes in list-mode. The D690 PET images were reconstructed with OSEM, OSEM+TOF, and OSEM+PSF. Gaussian post-filters of 4-9 mm FWHM were applied to find the parameters that provides harmonized SUV. We determined the SUV-harmonized parameter for each reconstruction algorithm. Then, the 10 PET images simulating clinical scan conditions were respectively generated to evaluate the bias and variability of SUV(max) and SUV(peak). The SUV(max) strongly depended not only on spatial resolution but also on image noise. On the other hand, the SUV(peak) was a robust metric to image noise level. TOF improved the variability of SUV(max) and SUV(peak). Thus, we were able to harmonize the spatial resolution using SUV(peak) based on the phantom study. Because SUV(max) was also strongly affected by image noise, sufficient count statistics is essential for SUV(max) harmonization. We recommended that TOF reconstruction and SUV(peak) metric should be used to harmonize SUV.
UR - http://www.scopus.com/inward/record.url?scp=84946417057&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84946417057&partnerID=8YFLogxK
U2 - 10.6009/jjrt.2015_JSRT_71.9.735
DO - 10.6009/jjrt.2015_JSRT_71.9.735
M3 - Article
C2 - 26400557
AN - SCOPUS:84946417057
SN - 0369-4305
VL - 71
SP - 735
EP - 745
JO - Nippon Hoshasen Gijutsu Gakkai zasshi
JF - Nippon Hoshasen Gijutsu Gakkai zasshi
IS - 9
ER -