Abstract

Purpose: To evaluate the optimal sequence for high-resolution magnetic resonance imaging (MRI) of the triangular fibrocartilage complex (TFCC) using compressed sensing-sensitivity encoding (CS-SENSE). Methods: Three-dimensional fast field echo T2-weighted images were obtained from 13 healthy volunteers using the original, high spatial resolution sequence with CS-SENSE [HR (CS-SENSE)] and without CS-SENSE (HR) and super-high spatial resolution sequence with CS-SENSE [S-HR (CS-SENSE)] and without CS-SENSE (S-HR). For qualitative analysis, the number of patients affected by motion artifacts in each sequence was counted, and the visualization of the TFCC anatomic structures and overall image quality were categorized. For the quantitative analysis, relative signal intensity (SI) and relative contrast of the lunate bone marrow, lunate cartilage, and disk proper in the wrist joint were all calculated. Results: The HR (CS-SENSE) sequence showed better visualization scores than the original sequence in the triangular ligament at the ulnar styloid tip, dorsal radioulnar ligament, and ulnotriquetral ligament. Similarly, the S-HR (CS-SENSE) sequence showed better visualization scores than the original sequence in the triangular ligament at the ulnar styloid tip and dorsal radioulnar ligament. Overall image quality scores were not significantly different, and motion artifacts in the HR and S-HR sequences were observed in 3 of the 13 patients. In contrast, the original sequence showed higher values than those in the HR (CS-SENSE) and S-HR (CS-SENSE) sequences in relative SI of the bone marrow and relative contrast of the cartilage-bone marrow and cartilage-disk proper. Conclusions: Out of the three sequences, the HR (CS-SENSE) sequence provided the highest visualization score and diagnostically sufficient image quality score, although relative SI and relative contrast were low. The HR (CS-SENSE) sequence may be clinically useful for imaging TFCCs.

Original languageEnglish
Article number110191
JournalEuropean Journal of Radiology
Volume149
DOIs
Publication statusPublished - Apr 2022

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'High-resolution magnetic resonance imaging of the triangular fibrocartilage complex using compressed sensing sensitivity encoding (SENSE)'. Together they form a unique fingerprint.

Cite this