High resolution measurement of protons emitted from medium-energy neutron induced reactions by means of a magnetic spectrograph

N. Koori, M. Hyakutake, M. Matoba, H. Ijiri, Y. Fujita, Y. Uozumi, S. Shirato, T. Motobayashi, T. Ohsawa, K. Sagara

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

The application of a magnetic spectrograph to measurements of medium-energy neutron induced reactions is superior in the intrinsic resolution to ordinary counter telescopes, position sensitive counter telescopes and magnetic quadrupole spectrometers. Protons emitted from the 2H(n, p)2n reaction were measured with a resolution of about 230 keV FWHM (0.37%) at an incident energy of 63 MeV. The finite geometry effect should be treated separately to analyze the measured spectra.

Original languageEnglish
Pages (from-to)737-743
Number of pages7
JournalNuclear Inst. and Methods in Physics Research, A
Volume278
Issue number3
DOIs
Publication statusPublished - Jun 15 1989

Fingerprint

Spectrographs
Telescopes
spectrographs
Neutrons
Protons
counters
telescopes
neutrons
protons
high resolution
Full width at half maximum
Spectrometers
quadrupoles
spectrometers
Geometry
energy
geometry

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics
  • Instrumentation

Cite this

High resolution measurement of protons emitted from medium-energy neutron induced reactions by means of a magnetic spectrograph. / Koori, N.; Hyakutake, M.; Matoba, M.; Ijiri, H.; Fujita, Y.; Uozumi, Y.; Shirato, S.; Motobayashi, T.; Ohsawa, T.; Sagara, K.

In: Nuclear Inst. and Methods in Physics Research, A, Vol. 278, No. 3, 15.06.1989, p. 737-743.

Research output: Contribution to journalArticle

Koori, N. ; Hyakutake, M. ; Matoba, M. ; Ijiri, H. ; Fujita, Y. ; Uozumi, Y. ; Shirato, S. ; Motobayashi, T. ; Ohsawa, T. ; Sagara, K. / High resolution measurement of protons emitted from medium-energy neutron induced reactions by means of a magnetic spectrograph. In: Nuclear Inst. and Methods in Physics Research, A. 1989 ; Vol. 278, No. 3. pp. 737-743.
@article{0890a1ad90014f809a277a8a629b93a0,
title = "High resolution measurement of protons emitted from medium-energy neutron induced reactions by means of a magnetic spectrograph",
abstract = "The application of a magnetic spectrograph to measurements of medium-energy neutron induced reactions is superior in the intrinsic resolution to ordinary counter telescopes, position sensitive counter telescopes and magnetic quadrupole spectrometers. Protons emitted from the 2H(n, p)2n reaction were measured with a resolution of about 230 keV FWHM (0.37{\%}) at an incident energy of 63 MeV. The finite geometry effect should be treated separately to analyze the measured spectra.",
author = "N. Koori and M. Hyakutake and M. Matoba and H. Ijiri and Y. Fujita and Y. Uozumi and S. Shirato and T. Motobayashi and T. Ohsawa and K. Sagara",
year = "1989",
month = "6",
day = "15",
doi = "10.1016/0168-9002(89)91197-2",
language = "English",
volume = "278",
pages = "737--743",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "3",

}

TY - JOUR

T1 - High resolution measurement of protons emitted from medium-energy neutron induced reactions by means of a magnetic spectrograph

AU - Koori, N.

AU - Hyakutake, M.

AU - Matoba, M.

AU - Ijiri, H.

AU - Fujita, Y.

AU - Uozumi, Y.

AU - Shirato, S.

AU - Motobayashi, T.

AU - Ohsawa, T.

AU - Sagara, K.

PY - 1989/6/15

Y1 - 1989/6/15

N2 - The application of a magnetic spectrograph to measurements of medium-energy neutron induced reactions is superior in the intrinsic resolution to ordinary counter telescopes, position sensitive counter telescopes and magnetic quadrupole spectrometers. Protons emitted from the 2H(n, p)2n reaction were measured with a resolution of about 230 keV FWHM (0.37%) at an incident energy of 63 MeV. The finite geometry effect should be treated separately to analyze the measured spectra.

AB - The application of a magnetic spectrograph to measurements of medium-energy neutron induced reactions is superior in the intrinsic resolution to ordinary counter telescopes, position sensitive counter telescopes and magnetic quadrupole spectrometers. Protons emitted from the 2H(n, p)2n reaction were measured with a resolution of about 230 keV FWHM (0.37%) at an incident energy of 63 MeV. The finite geometry effect should be treated separately to analyze the measured spectra.

UR - http://www.scopus.com/inward/record.url?scp=0024681722&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024681722&partnerID=8YFLogxK

U2 - 10.1016/0168-9002(89)91197-2

DO - 10.1016/0168-9002(89)91197-2

M3 - Article

AN - SCOPUS:0024681722

VL - 278

SP - 737

EP - 743

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 3

ER -