High-throughput immunophenotyping by surface plasmon resonance imaging

Koichi Kato, Toshinari Ishimuro, Yusuke Arima, Isao Hirata, Hiroo Iwata

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Cell binding assays on antibody arrays permit the rapid immunophenotyping of living cells. The throughput of the analysis, however, is still limited due to our inability to perform parallel and quantitative detection of cells captured on the array. To address this limitation, we employed here an imaging technique based on surface plasmon resonance (SPR). SPR has been frequently used to monitor capture of proteins on antibody microarrays, while few cases were reported for capture of cells. Antibody arrays were prepared through the photopatterning of an alkanethiol monolayer on a gold-evaporated glass plate and the subsequent immobilization of various antibodies onto 4-9 separate spots created by photopatterning. A glass slip was mounted onto the array with a thin spacer to construct a parallel-plate chamber. Leukemia cells were injected into the chamber to conduct a binding assay, while refractive index changes at the vicinity of the array surface were monitored by SPR imaging. We observed that SPR signals were intensified on specific antibody spots but not on nonspecific spots. Confocal laser scanning microscopy revealed that the observed SPR signals were attributed to cell deformations caused by multivalent interactions with immobilized antibody, which effectively elevated the refractive index of a medium phase within an evanescent field. This effect could be suitably utilized to monitor quantitatively cell binding to multiple spots from a heterogeneous cell population.

Original languageEnglish
Pages (from-to)8616-8623
Number of pages8
JournalAnalytical chemistry
Volume79
Issue number22
DOIs
Publication statusPublished - Nov 15 2007

Fingerprint

Surface plasmon resonance
Throughput
Imaging techniques
Antibodies
Assays
Refractive index
Cells
Immobilized Antibodies
Evanescent fields
Glass
Microarrays
Gold
Monolayers
Microscopic examination
Scanning
Lasers
Proteins

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Cite this

High-throughput immunophenotyping by surface plasmon resonance imaging. / Kato, Koichi; Ishimuro, Toshinari; Arima, Yusuke; Hirata, Isao; Iwata, Hiroo.

In: Analytical chemistry, Vol. 79, No. 22, 15.11.2007, p. 8616-8623.

Research output: Contribution to journalArticle

Kato, Koichi ; Ishimuro, Toshinari ; Arima, Yusuke ; Hirata, Isao ; Iwata, Hiroo. / High-throughput immunophenotyping by surface plasmon resonance imaging. In: Analytical chemistry. 2007 ; Vol. 79, No. 22. pp. 8616-8623.
@article{2b40dcb462f246a482b41eedc6c6fec5,
title = "High-throughput immunophenotyping by surface plasmon resonance imaging",
abstract = "Cell binding assays on antibody arrays permit the rapid immunophenotyping of living cells. The throughput of the analysis, however, is still limited due to our inability to perform parallel and quantitative detection of cells captured on the array. To address this limitation, we employed here an imaging technique based on surface plasmon resonance (SPR). SPR has been frequently used to monitor capture of proteins on antibody microarrays, while few cases were reported for capture of cells. Antibody arrays were prepared through the photopatterning of an alkanethiol monolayer on a gold-evaporated glass plate and the subsequent immobilization of various antibodies onto 4-9 separate spots created by photopatterning. A glass slip was mounted onto the array with a thin spacer to construct a parallel-plate chamber. Leukemia cells were injected into the chamber to conduct a binding assay, while refractive index changes at the vicinity of the array surface were monitored by SPR imaging. We observed that SPR signals were intensified on specific antibody spots but not on nonspecific spots. Confocal laser scanning microscopy revealed that the observed SPR signals were attributed to cell deformations caused by multivalent interactions with immobilized antibody, which effectively elevated the refractive index of a medium phase within an evanescent field. This effect could be suitably utilized to monitor quantitatively cell binding to multiple spots from a heterogeneous cell population.",
author = "Koichi Kato and Toshinari Ishimuro and Yusuke Arima and Isao Hirata and Hiroo Iwata",
year = "2007",
month = "11",
day = "15",
doi = "10.1021/ac071548s",
language = "English",
volume = "79",
pages = "8616--8623",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "22",

}

TY - JOUR

T1 - High-throughput immunophenotyping by surface plasmon resonance imaging

AU - Kato, Koichi

AU - Ishimuro, Toshinari

AU - Arima, Yusuke

AU - Hirata, Isao

AU - Iwata, Hiroo

PY - 2007/11/15

Y1 - 2007/11/15

N2 - Cell binding assays on antibody arrays permit the rapid immunophenotyping of living cells. The throughput of the analysis, however, is still limited due to our inability to perform parallel and quantitative detection of cells captured on the array. To address this limitation, we employed here an imaging technique based on surface plasmon resonance (SPR). SPR has been frequently used to monitor capture of proteins on antibody microarrays, while few cases were reported for capture of cells. Antibody arrays were prepared through the photopatterning of an alkanethiol monolayer on a gold-evaporated glass plate and the subsequent immobilization of various antibodies onto 4-9 separate spots created by photopatterning. A glass slip was mounted onto the array with a thin spacer to construct a parallel-plate chamber. Leukemia cells were injected into the chamber to conduct a binding assay, while refractive index changes at the vicinity of the array surface were monitored by SPR imaging. We observed that SPR signals were intensified on specific antibody spots but not on nonspecific spots. Confocal laser scanning microscopy revealed that the observed SPR signals were attributed to cell deformations caused by multivalent interactions with immobilized antibody, which effectively elevated the refractive index of a medium phase within an evanescent field. This effect could be suitably utilized to monitor quantitatively cell binding to multiple spots from a heterogeneous cell population.

AB - Cell binding assays on antibody arrays permit the rapid immunophenotyping of living cells. The throughput of the analysis, however, is still limited due to our inability to perform parallel and quantitative detection of cells captured on the array. To address this limitation, we employed here an imaging technique based on surface plasmon resonance (SPR). SPR has been frequently used to monitor capture of proteins on antibody microarrays, while few cases were reported for capture of cells. Antibody arrays were prepared through the photopatterning of an alkanethiol monolayer on a gold-evaporated glass plate and the subsequent immobilization of various antibodies onto 4-9 separate spots created by photopatterning. A glass slip was mounted onto the array with a thin spacer to construct a parallel-plate chamber. Leukemia cells were injected into the chamber to conduct a binding assay, while refractive index changes at the vicinity of the array surface were monitored by SPR imaging. We observed that SPR signals were intensified on specific antibody spots but not on nonspecific spots. Confocal laser scanning microscopy revealed that the observed SPR signals were attributed to cell deformations caused by multivalent interactions with immobilized antibody, which effectively elevated the refractive index of a medium phase within an evanescent field. This effect could be suitably utilized to monitor quantitatively cell binding to multiple spots from a heterogeneous cell population.

UR - http://www.scopus.com/inward/record.url?scp=36448938725&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=36448938725&partnerID=8YFLogxK

U2 - 10.1021/ac071548s

DO - 10.1021/ac071548s

M3 - Article

C2 - 17927142

AN - SCOPUS:36448938725

VL - 79

SP - 8616

EP - 8623

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 22

ER -