Highly sensitive laser fluorimetry of europium(III) with1,1,1-trifluoro-4-(2-thienyl)-2,4-butanedione

Sunao Yamada, Fumihiro Miyoshi, Koji Kano, Teiichiro Ogawa

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

The detection limit for tris(1,1,1-trifluoro-4-(2-thienyl)-2,4-butanediono)-europium(III) is established as 2 pg l-1. A highly sensitive fluorimetric system consisting of a nitrogen laser and a pulse-gated photon counter is used.

Original languageEnglish
Pages (from-to)195-198
Number of pages4
JournalAnalytica Chimica Acta
Volume127
Issue numberC
DOIs
Publication statusPublished - Jun 1 1981

Fingerprint

Europium
europium
fluorometry
Fluorometry
Gas Lasers
Photons
Limit of Detection
Laser pulses
Lasers
Nitrogen
laser
nitrogen
detection

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry
  • Biochemistry
  • Environmental Chemistry
  • Spectroscopy

Cite this

Highly sensitive laser fluorimetry of europium(III) with1,1,1-trifluoro-4-(2-thienyl)-2,4-butanedione. / Yamada, Sunao; Miyoshi, Fumihiro; Kano, Koji; Ogawa, Teiichiro.

In: Analytica Chimica Acta, Vol. 127, No. C, 01.06.1981, p. 195-198.

Research output: Contribution to journalArticle

Yamada, Sunao ; Miyoshi, Fumihiro ; Kano, Koji ; Ogawa, Teiichiro. / Highly sensitive laser fluorimetry of europium(III) with1,1,1-trifluoro-4-(2-thienyl)-2,4-butanedione. In: Analytica Chimica Acta. 1981 ; Vol. 127, No. C. pp. 195-198.
@article{f86df789244f4d2f908d89f3e57eb92b,
title = "Highly sensitive laser fluorimetry of europium(III) with1,1,1-trifluoro-4-(2-thienyl)-2,4-butanedione",
abstract = "The detection limit for tris(1,1,1-trifluoro-4-(2-thienyl)-2,4-butanediono)-europium(III) is established as 2 pg l-1. A highly sensitive fluorimetric system consisting of a nitrogen laser and a pulse-gated photon counter is used.",
author = "Sunao Yamada and Fumihiro Miyoshi and Koji Kano and Teiichiro Ogawa",
year = "1981",
month = "6",
day = "1",
doi = "10.1016/S0003-2670(01)83975-1",
language = "English",
volume = "127",
pages = "195--198",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",
number = "C",

}

TY - JOUR

T1 - Highly sensitive laser fluorimetry of europium(III) with1,1,1-trifluoro-4-(2-thienyl)-2,4-butanedione

AU - Yamada, Sunao

AU - Miyoshi, Fumihiro

AU - Kano, Koji

AU - Ogawa, Teiichiro

PY - 1981/6/1

Y1 - 1981/6/1

N2 - The detection limit for tris(1,1,1-trifluoro-4-(2-thienyl)-2,4-butanediono)-europium(III) is established as 2 pg l-1. A highly sensitive fluorimetric system consisting of a nitrogen laser and a pulse-gated photon counter is used.

AB - The detection limit for tris(1,1,1-trifluoro-4-(2-thienyl)-2,4-butanediono)-europium(III) is established as 2 pg l-1. A highly sensitive fluorimetric system consisting of a nitrogen laser and a pulse-gated photon counter is used.

UR - http://www.scopus.com/inward/record.url?scp=0011788255&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0011788255&partnerID=8YFLogxK

U2 - 10.1016/S0003-2670(01)83975-1

DO - 10.1016/S0003-2670(01)83975-1

M3 - Article

VL - 127

SP - 195

EP - 198

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

IS - C

ER -