Abstract

Electromagnetic interference (EM1) with electronic medical equipment by the handsets of mobile telephones is a well documented problem in hospitals. To gain information about how to build an EMI-free hospital and how to make rooms safe for mobile telephone handset use in the hospital building, the authors measured the shielding capacities of a concrete wall, concrete blocks, a steel door, and steel-surfaced partition panels. The shielding capacities of these materials were 2-7 dB for the concrete wall, 6-8 dB for the concrete blocks, 19-27 dB for the steel door, and 20-37 dB for the steel- surfaced partition panels. These results indicate that care should be taken to shield electronic equipment from signals coming from neighboring rooms and from those under and above any patient room in which such equipment is in use. Electricity-conductive paint, electricity-conductive wallpaper, and electricity-conductive cloth are examples of inexpensive materials that can increase shielding capacity.

Original languageEnglish
Pages (from-to)489-496
Number of pages8
JournalBiomedical Instrumentation and Technology
Volume32
Issue number5
Publication statusPublished - Sep 1 1998

Fingerprint

Telephone sets
Shielding
Concrete blocks
Electricity
Steel
Concretes
Partitions (building)
Electronic medical equipment
Signal interference
Telephone
Paint
Electronic equipment

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering
  • Computer Networks and Communications

Cite this

Hospital construction materials : Poor shielding capacity with respect to signals transmitted by mobile telephones. / Hanada, Eisuke; Watanabe, Yoshiaki; Antoku, Yasuaki; Kenjo, Yuko; Nutahara, Hitomi; Nose, Yoshiaki.

In: Biomedical Instrumentation and Technology, Vol. 32, No. 5, 01.09.1998, p. 489-496.

Research output: Contribution to journalArticle

Hanada, E, Watanabe, Y, Antoku, Y, Kenjo, Y, Nutahara, H & Nose, Y 1998, 'Hospital construction materials: Poor shielding capacity with respect to signals transmitted by mobile telephones', Biomedical Instrumentation and Technology, vol. 32, no. 5, pp. 489-496.
Hanada, Eisuke ; Watanabe, Yoshiaki ; Antoku, Yasuaki ; Kenjo, Yuko ; Nutahara, Hitomi ; Nose, Yoshiaki. / Hospital construction materials : Poor shielding capacity with respect to signals transmitted by mobile telephones. In: Biomedical Instrumentation and Technology. 1998 ; Vol. 32, No. 5. pp. 489-496.
@article{c63693c08ad04a4fab884ada691e64d7,
title = "Hospital construction materials: Poor shielding capacity with respect to signals transmitted by mobile telephones",
abstract = "Electromagnetic interference (EM1) with electronic medical equipment by the handsets of mobile telephones is a well documented problem in hospitals. To gain information about how to build an EMI-free hospital and how to make rooms safe for mobile telephone handset use in the hospital building, the authors measured the shielding capacities of a concrete wall, concrete blocks, a steel door, and steel-surfaced partition panels. The shielding capacities of these materials were 2-7 dB for the concrete wall, 6-8 dB for the concrete blocks, 19-27 dB for the steel door, and 20-37 dB for the steel- surfaced partition panels. These results indicate that care should be taken to shield electronic equipment from signals coming from neighboring rooms and from those under and above any patient room in which such equipment is in use. Electricity-conductive paint, electricity-conductive wallpaper, and electricity-conductive cloth are examples of inexpensive materials that can increase shielding capacity.",
author = "Eisuke Hanada and Yoshiaki Watanabe and Yasuaki Antoku and Yuko Kenjo and Hitomi Nutahara and Yoshiaki Nose",
year = "1998",
month = "9",
day = "1",
language = "English",
volume = "32",
pages = "489--496",
journal = "Biomedical Instrumentation and Technology",
issn = "0899-8205",
publisher = "Association for the Advancement of Medical Instrumentation",
number = "5",

}

TY - JOUR

T1 - Hospital construction materials

T2 - Poor shielding capacity with respect to signals transmitted by mobile telephones

AU - Hanada, Eisuke

AU - Watanabe, Yoshiaki

AU - Antoku, Yasuaki

AU - Kenjo, Yuko

AU - Nutahara, Hitomi

AU - Nose, Yoshiaki

PY - 1998/9/1

Y1 - 1998/9/1

N2 - Electromagnetic interference (EM1) with electronic medical equipment by the handsets of mobile telephones is a well documented problem in hospitals. To gain information about how to build an EMI-free hospital and how to make rooms safe for mobile telephone handset use in the hospital building, the authors measured the shielding capacities of a concrete wall, concrete blocks, a steel door, and steel-surfaced partition panels. The shielding capacities of these materials were 2-7 dB for the concrete wall, 6-8 dB for the concrete blocks, 19-27 dB for the steel door, and 20-37 dB for the steel- surfaced partition panels. These results indicate that care should be taken to shield electronic equipment from signals coming from neighboring rooms and from those under and above any patient room in which such equipment is in use. Electricity-conductive paint, electricity-conductive wallpaper, and electricity-conductive cloth are examples of inexpensive materials that can increase shielding capacity.

AB - Electromagnetic interference (EM1) with electronic medical equipment by the handsets of mobile telephones is a well documented problem in hospitals. To gain information about how to build an EMI-free hospital and how to make rooms safe for mobile telephone handset use in the hospital building, the authors measured the shielding capacities of a concrete wall, concrete blocks, a steel door, and steel-surfaced partition panels. The shielding capacities of these materials were 2-7 dB for the concrete wall, 6-8 dB for the concrete blocks, 19-27 dB for the steel door, and 20-37 dB for the steel- surfaced partition panels. These results indicate that care should be taken to shield electronic equipment from signals coming from neighboring rooms and from those under and above any patient room in which such equipment is in use. Electricity-conductive paint, electricity-conductive wallpaper, and electricity-conductive cloth are examples of inexpensive materials that can increase shielding capacity.

UR - http://www.scopus.com/inward/record.url?scp=0032170187&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032170187&partnerID=8YFLogxK

M3 - Article

C2 - 9800005

AN - SCOPUS:0032170187

VL - 32

SP - 489

EP - 496

JO - Biomedical Instrumentation and Technology

JF - Biomedical Instrumentation and Technology

SN - 0899-8205

IS - 5

ER -