Hydrogen entry into Fe and high strength steels under simulated atmospheric corrosion

Eiji Akiyama, Songjie Li, Tadashi Shinohara, Zuogui Zhang, Kaneaki Tsuzaki

Research output: Contribution to journalArticle

52 Citations (Scopus)

Abstract

Electrochemical hydrogen permeation tests of Fe sheets under two cyclic corrosion test (CCT) conditions were performed to understand hydrogen entry behavior under atmospheric corrosions. Hydrogen entry into 1300 MPa-class high strength steels under two CCT conditions was also investigated using thermal desorption analysis. One CCT consisted of salt spray, dry and wet stages (Salt Spray CCT; SSCCT), and the other consisted of dry and wet stages after NaCl deposition (Dry-Wet CCT; DWCCT). The corrosion rates of Fe and the steels were almost constant under SSCCT and they decreased under DWCCT with time. Nevertheless, both CCTs resulted in increases in hydrogen permeation current and diffusible hydrogen content with time indicating enhancement of hydrogen entry. Corrosion current monitored by means of an atmospheric corrosion monitoring sensor consisting of Fe anode and Ag cathode decreased obviously under dry stage of the CCTs, whereas hydrogen permeation was high at the beginning of the dry stage. The discrepancy between hydrogen entry and corrosion rate indicates that the hydrogen entry is not directly controlled by corrosion rate. Increase in acidity of underlying rust layer with growth of rust layer monitored using a W/WO3 electrode is considered to be one of the factors affecting the hydrogen entry efficiency.

Original languageEnglish
Pages (from-to)1799-1805
Number of pages7
JournalElectrochimica Acta
Volume56
Issue number4
DOIs
Publication statusPublished - Jan 15 2011
Externally publishedYes

Fingerprint

Atmospheric corrosion
High strength steel
Hydrogen
Corrosion
Corrosion rate
Permeation
Salts
Thermal desorption
Steel
Acidity
Anodes
Cathodes

All Science Journal Classification (ASJC) codes

  • Chemical Engineering(all)
  • Electrochemistry

Cite this

Hydrogen entry into Fe and high strength steels under simulated atmospheric corrosion. / Akiyama, Eiji; Li, Songjie; Shinohara, Tadashi; Zhang, Zuogui; Tsuzaki, Kaneaki.

In: Electrochimica Acta, Vol. 56, No. 4, 15.01.2011, p. 1799-1805.

Research output: Contribution to journalArticle

Akiyama, Eiji ; Li, Songjie ; Shinohara, Tadashi ; Zhang, Zuogui ; Tsuzaki, Kaneaki. / Hydrogen entry into Fe and high strength steels under simulated atmospheric corrosion. In: Electrochimica Acta. 2011 ; Vol. 56, No. 4. pp. 1799-1805.
@article{aa85f80ec9664226bea5dfc8fc2f6edd,
title = "Hydrogen entry into Fe and high strength steels under simulated atmospheric corrosion",
abstract = "Electrochemical hydrogen permeation tests of Fe sheets under two cyclic corrosion test (CCT) conditions were performed to understand hydrogen entry behavior under atmospheric corrosions. Hydrogen entry into 1300 MPa-class high strength steels under two CCT conditions was also investigated using thermal desorption analysis. One CCT consisted of salt spray, dry and wet stages (Salt Spray CCT; SSCCT), and the other consisted of dry and wet stages after NaCl deposition (Dry-Wet CCT; DWCCT). The corrosion rates of Fe and the steels were almost constant under SSCCT and they decreased under DWCCT with time. Nevertheless, both CCTs resulted in increases in hydrogen permeation current and diffusible hydrogen content with time indicating enhancement of hydrogen entry. Corrosion current monitored by means of an atmospheric corrosion monitoring sensor consisting of Fe anode and Ag cathode decreased obviously under dry stage of the CCTs, whereas hydrogen permeation was high at the beginning of the dry stage. The discrepancy between hydrogen entry and corrosion rate indicates that the hydrogen entry is not directly controlled by corrosion rate. Increase in acidity of underlying rust layer with growth of rust layer monitored using a W/WO3 electrode is considered to be one of the factors affecting the hydrogen entry efficiency.",
author = "Eiji Akiyama and Songjie Li and Tadashi Shinohara and Zuogui Zhang and Kaneaki Tsuzaki",
year = "2011",
month = "1",
day = "15",
doi = "10.1016/j.electacta.2010.09.043",
language = "English",
volume = "56",
pages = "1799--1805",
journal = "Electrochimica Acta",
issn = "0013-4686",
publisher = "Elsevier Limited",
number = "4",

}

TY - JOUR

T1 - Hydrogen entry into Fe and high strength steels under simulated atmospheric corrosion

AU - Akiyama, Eiji

AU - Li, Songjie

AU - Shinohara, Tadashi

AU - Zhang, Zuogui

AU - Tsuzaki, Kaneaki

PY - 2011/1/15

Y1 - 2011/1/15

N2 - Electrochemical hydrogen permeation tests of Fe sheets under two cyclic corrosion test (CCT) conditions were performed to understand hydrogen entry behavior under atmospheric corrosions. Hydrogen entry into 1300 MPa-class high strength steels under two CCT conditions was also investigated using thermal desorption analysis. One CCT consisted of salt spray, dry and wet stages (Salt Spray CCT; SSCCT), and the other consisted of dry and wet stages after NaCl deposition (Dry-Wet CCT; DWCCT). The corrosion rates of Fe and the steels were almost constant under SSCCT and they decreased under DWCCT with time. Nevertheless, both CCTs resulted in increases in hydrogen permeation current and diffusible hydrogen content with time indicating enhancement of hydrogen entry. Corrosion current monitored by means of an atmospheric corrosion monitoring sensor consisting of Fe anode and Ag cathode decreased obviously under dry stage of the CCTs, whereas hydrogen permeation was high at the beginning of the dry stage. The discrepancy between hydrogen entry and corrosion rate indicates that the hydrogen entry is not directly controlled by corrosion rate. Increase in acidity of underlying rust layer with growth of rust layer monitored using a W/WO3 electrode is considered to be one of the factors affecting the hydrogen entry efficiency.

AB - Electrochemical hydrogen permeation tests of Fe sheets under two cyclic corrosion test (CCT) conditions were performed to understand hydrogen entry behavior under atmospheric corrosions. Hydrogen entry into 1300 MPa-class high strength steels under two CCT conditions was also investigated using thermal desorption analysis. One CCT consisted of salt spray, dry and wet stages (Salt Spray CCT; SSCCT), and the other consisted of dry and wet stages after NaCl deposition (Dry-Wet CCT; DWCCT). The corrosion rates of Fe and the steels were almost constant under SSCCT and they decreased under DWCCT with time. Nevertheless, both CCTs resulted in increases in hydrogen permeation current and diffusible hydrogen content with time indicating enhancement of hydrogen entry. Corrosion current monitored by means of an atmospheric corrosion monitoring sensor consisting of Fe anode and Ag cathode decreased obviously under dry stage of the CCTs, whereas hydrogen permeation was high at the beginning of the dry stage. The discrepancy between hydrogen entry and corrosion rate indicates that the hydrogen entry is not directly controlled by corrosion rate. Increase in acidity of underlying rust layer with growth of rust layer monitored using a W/WO3 electrode is considered to be one of the factors affecting the hydrogen entry efficiency.

UR - http://www.scopus.com/inward/record.url?scp=79151474792&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79151474792&partnerID=8YFLogxK

U2 - 10.1016/j.electacta.2010.09.043

DO - 10.1016/j.electacta.2010.09.043

M3 - Article

AN - SCOPUS:79151474792

VL - 56

SP - 1799

EP - 1805

JO - Electrochimica Acta

JF - Electrochimica Acta

SN - 0013-4686

IS - 4

ER -