Computed DWI (cDWI) is a mathematical technique that calculates arbitrary higher b value images from at least two different lower b values. In addition, the removal of high intensity noise with image processing on cDWI could improve cholesteatoma-background contrast-to-noise ratio (CNR). In the present study, noise reduction was performed by the cut-off values of apparent diffusion coefficient (ADC) less than 0 and 0.4 × 10−3 s/mm2. The cholesteatoma to non-cholesteatoma CNR was increased using a noise reduction algorithm for clinical setting.

Original languageEnglish
Pages (from-to)233-237
Number of pages5
JournalMagnetic Resonance in Medical Sciences
Volume18
Issue number3
DOIs
Publication statusPublished - Jan 1 2019

Fingerprint

Middle Ear Cholesteatoma
Noise
Cholesteatoma

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Cite this

Improved visualization of middle ear cholesteatoma with computed diffusion-weighted imaging. / Yamashita, Koji; Hiwatashi, Akio; Togao, Osamu; Kikuchi, Kazufumi; Shimomiya, Yamato; Kamei, Ryotaro; Momosaka, Daichi; Matsumoto, Nozomu; Kobayashi, Kouji; Takemura, Atsushi; Kwee, Thomas Christian; Takahara, Taro; Honda, Hiroshi.

In: Magnetic Resonance in Medical Sciences, Vol. 18, No. 3, 01.01.2019, p. 233-237.

Research output: Contribution to journalArticle

Yamashita, K, Hiwatashi, A, Togao, O, Kikuchi, K, Shimomiya, Y, Kamei, R, Momosaka, D, Matsumoto, N, Kobayashi, K, Takemura, A, Kwee, TC, Takahara, T & Honda, H 2019, 'Improved visualization of middle ear cholesteatoma with computed diffusion-weighted imaging', Magnetic Resonance in Medical Sciences, vol. 18, no. 3, pp. 233-237. https://doi.org/10.2463/mrms.tn.2018-0068
Yamashita, Koji ; Hiwatashi, Akio ; Togao, Osamu ; Kikuchi, Kazufumi ; Shimomiya, Yamato ; Kamei, Ryotaro ; Momosaka, Daichi ; Matsumoto, Nozomu ; Kobayashi, Kouji ; Takemura, Atsushi ; Kwee, Thomas Christian ; Takahara, Taro ; Honda, Hiroshi. / Improved visualization of middle ear cholesteatoma with computed diffusion-weighted imaging. In: Magnetic Resonance in Medical Sciences. 2019 ; Vol. 18, No. 3. pp. 233-237.
@article{1b754f1b117c4832855faa05a5144680,
title = "Improved visualization of middle ear cholesteatoma with computed diffusion-weighted imaging",
abstract = "Computed DWI (cDWI) is a mathematical technique that calculates arbitrary higher b value images from at least two different lower b values. In addition, the removal of high intensity noise with image processing on cDWI could improve cholesteatoma-background contrast-to-noise ratio (CNR). In the present study, noise reduction was performed by the cut-off values of apparent diffusion coefficient (ADC) less than 0 and 0.4 × 10−3 s/mm2. The cholesteatoma to non-cholesteatoma CNR was increased using a noise reduction algorithm for clinical setting.",
author = "Koji Yamashita and Akio Hiwatashi and Osamu Togao and Kazufumi Kikuchi and Yamato Shimomiya and Ryotaro Kamei and Daichi Momosaka and Nozomu Matsumoto and Kouji Kobayashi and Atsushi Takemura and Kwee, {Thomas Christian} and Taro Takahara and Hiroshi Honda",
year = "2019",
month = "1",
day = "1",
doi = "10.2463/mrms.tn.2018-0068",
language = "English",
volume = "18",
pages = "233--237",
journal = "Magnetic Resonance in Medical Sciences",
issn = "1347-3182",
publisher = "Japan Society of Magnetic Resonance in Medicine",
number = "3",

}

TY - JOUR

T1 - Improved visualization of middle ear cholesteatoma with computed diffusion-weighted imaging

AU - Yamashita, Koji

AU - Hiwatashi, Akio

AU - Togao, Osamu

AU - Kikuchi, Kazufumi

AU - Shimomiya, Yamato

AU - Kamei, Ryotaro

AU - Momosaka, Daichi

AU - Matsumoto, Nozomu

AU - Kobayashi, Kouji

AU - Takemura, Atsushi

AU - Kwee, Thomas Christian

AU - Takahara, Taro

AU - Honda, Hiroshi

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Computed DWI (cDWI) is a mathematical technique that calculates arbitrary higher b value images from at least two different lower b values. In addition, the removal of high intensity noise with image processing on cDWI could improve cholesteatoma-background contrast-to-noise ratio (CNR). In the present study, noise reduction was performed by the cut-off values of apparent diffusion coefficient (ADC) less than 0 and 0.4 × 10−3 s/mm2. The cholesteatoma to non-cholesteatoma CNR was increased using a noise reduction algorithm for clinical setting.

AB - Computed DWI (cDWI) is a mathematical technique that calculates arbitrary higher b value images from at least two different lower b values. In addition, the removal of high intensity noise with image processing on cDWI could improve cholesteatoma-background contrast-to-noise ratio (CNR). In the present study, noise reduction was performed by the cut-off values of apparent diffusion coefficient (ADC) less than 0 and 0.4 × 10−3 s/mm2. The cholesteatoma to non-cholesteatoma CNR was increased using a noise reduction algorithm for clinical setting.

UR - http://www.scopus.com/inward/record.url?scp=85069891601&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85069891601&partnerID=8YFLogxK

U2 - 10.2463/mrms.tn.2018-0068

DO - 10.2463/mrms.tn.2018-0068

M3 - Article

C2 - 30518733

AN - SCOPUS:85069891601

VL - 18

SP - 233

EP - 237

JO - Magnetic Resonance in Medical Sciences

JF - Magnetic Resonance in Medical Sciences

SN - 1347-3182

IS - 3

ER -