Improvement in failure diagnosis of flowmeters based on control limits

Yoshifumi Tsuge, Kazushi Ishimoto, Kazuhiro Takeda, Hisayoshi Matsuyama

Research output: Contribution to journalArticle

Abstract

Failure diagnosis of flowmeters based on control limits has been developed as a method to identify faulty flowmeters, which should be calibrated during a maintenance period, during plant operation. This method is very useful for the diagnosis of flowmeters having faulty errors with magnitudes greater than three times of their control limits. However, there is a shortcoming that the diagnostic results given by this method often miss giving alarms when they should, or give false diagnoses, for faulty errors with magnitudes less than three times of their control limits. In this study, the diagnostic results given by this method during plant operation are not adopted in a straightforward manner. Instead, at least one flowmeter is selected and calibrated during a maintenance period, to identify the true value of a flow rate. As a result, the diagnostic accuracy can be improved by performing a second diagnosis using the calibrated values of the flow rates. Furthermore, the performance of the method presented is demonstrated by numerical experiments on a simplified refinery model containing 11 flowmeters.

Original languageEnglish
Pages (from-to)1243-1251
Number of pages9
JournalJOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Volume37
Issue number10
DOIs
Publication statusPublished - Oct 1 2004

Fingerprint

Flowmeters
Flow rate
Experiments

All Science Journal Classification (ASJC) codes

  • Chemistry(all)
  • Chemical Engineering(all)

Cite this

Improvement in failure diagnosis of flowmeters based on control limits. / Tsuge, Yoshifumi; Ishimoto, Kazushi; Takeda, Kazuhiro; Matsuyama, Hisayoshi.

In: JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, Vol. 37, No. 10, 01.10.2004, p. 1243-1251.

Research output: Contribution to journalArticle

Tsuge, Yoshifumi ; Ishimoto, Kazushi ; Takeda, Kazuhiro ; Matsuyama, Hisayoshi. / Improvement in failure diagnosis of flowmeters based on control limits. In: JOURNAL OF CHEMICAL ENGINEERING OF JAPAN. 2004 ; Vol. 37, No. 10. pp. 1243-1251.
@article{8798ad67f10d417aba63bce05e073672,
title = "Improvement in failure diagnosis of flowmeters based on control limits",
abstract = "Failure diagnosis of flowmeters based on control limits has been developed as a method to identify faulty flowmeters, which should be calibrated during a maintenance period, during plant operation. This method is very useful for the diagnosis of flowmeters having faulty errors with magnitudes greater than three times of their control limits. However, there is a shortcoming that the diagnostic results given by this method often miss giving alarms when they should, or give false diagnoses, for faulty errors with magnitudes less than three times of their control limits. In this study, the diagnostic results given by this method during plant operation are not adopted in a straightforward manner. Instead, at least one flowmeter is selected and calibrated during a maintenance period, to identify the true value of a flow rate. As a result, the diagnostic accuracy can be improved by performing a second diagnosis using the calibrated values of the flow rates. Furthermore, the performance of the method presented is demonstrated by numerical experiments on a simplified refinery model containing 11 flowmeters.",
author = "Yoshifumi Tsuge and Kazushi Ishimoto and Kazuhiro Takeda and Hisayoshi Matsuyama",
year = "2004",
month = "10",
day = "1",
doi = "10.1252/jcej.37.1243",
language = "English",
volume = "37",
pages = "1243--1251",
journal = "Journal of Chemical Engineering of Japan",
issn = "0021-9592",
publisher = "Society of Chemical Engineers, Japan",
number = "10",

}

TY - JOUR

T1 - Improvement in failure diagnosis of flowmeters based on control limits

AU - Tsuge, Yoshifumi

AU - Ishimoto, Kazushi

AU - Takeda, Kazuhiro

AU - Matsuyama, Hisayoshi

PY - 2004/10/1

Y1 - 2004/10/1

N2 - Failure diagnosis of flowmeters based on control limits has been developed as a method to identify faulty flowmeters, which should be calibrated during a maintenance period, during plant operation. This method is very useful for the diagnosis of flowmeters having faulty errors with magnitudes greater than three times of their control limits. However, there is a shortcoming that the diagnostic results given by this method often miss giving alarms when they should, or give false diagnoses, for faulty errors with magnitudes less than three times of their control limits. In this study, the diagnostic results given by this method during plant operation are not adopted in a straightforward manner. Instead, at least one flowmeter is selected and calibrated during a maintenance period, to identify the true value of a flow rate. As a result, the diagnostic accuracy can be improved by performing a second diagnosis using the calibrated values of the flow rates. Furthermore, the performance of the method presented is demonstrated by numerical experiments on a simplified refinery model containing 11 flowmeters.

AB - Failure diagnosis of flowmeters based on control limits has been developed as a method to identify faulty flowmeters, which should be calibrated during a maintenance period, during plant operation. This method is very useful for the diagnosis of flowmeters having faulty errors with magnitudes greater than three times of their control limits. However, there is a shortcoming that the diagnostic results given by this method often miss giving alarms when they should, or give false diagnoses, for faulty errors with magnitudes less than three times of their control limits. In this study, the diagnostic results given by this method during plant operation are not adopted in a straightforward manner. Instead, at least one flowmeter is selected and calibrated during a maintenance period, to identify the true value of a flow rate. As a result, the diagnostic accuracy can be improved by performing a second diagnosis using the calibrated values of the flow rates. Furthermore, the performance of the method presented is demonstrated by numerical experiments on a simplified refinery model containing 11 flowmeters.

UR - http://www.scopus.com/inward/record.url?scp=7744244261&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=7744244261&partnerID=8YFLogxK

U2 - 10.1252/jcej.37.1243

DO - 10.1252/jcej.37.1243

M3 - Article

AN - SCOPUS:7744244261

VL - 37

SP - 1243

EP - 1251

JO - Journal of Chemical Engineering of Japan

JF - Journal of Chemical Engineering of Japan

SN - 0021-9592

IS - 10

ER -