TY - JOUR
T1 - Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body
T2 - A case report
AU - Kumagai, Hozumi
AU - Nio, Kenta
AU - Shirakawa, Tsuyoshi
AU - Uchino, Keita
AU - Kusaba, Hitoshi
AU - Isobe, Taichi
AU - Komoda, Masato
AU - Tamura, Shingo
AU - Maeyama, Ryo
AU - Nagai, Eishi
AU - Akashi, Koichi
AU - Baba, Eishi
PY - 2012
Y1 - 2012
N2 - Introduction. Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. Case presentation. A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Conclusions: Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patients general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.
AB - Introduction. Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. Case presentation. A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Conclusions: Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patients general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.
UR - http://www.scopus.com/inward/record.url?scp=84866289288&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84866289288&partnerID=8YFLogxK
U2 - 10.1186/1752-1947-6-315
DO - 10.1186/1752-1947-6-315
M3 - Article
C2 - 22992342
AN - SCOPUS:84866289288
SN - 1752-1947
VL - 6
JO - Journal of Medical Case Reports
JF - Journal of Medical Case Reports
M1 - 315
ER -