N2 - Purpose: The aim of this multi-scale in silico study was to evaluate the influence of resorption cavities on the mechanical properties and load distribution in cortical bone after implant placement with two different drilling protocols. Material and methods: Two different micro-scale bone structures were assessed: cortical bone models with cavities (test) and without cavities (control) were designed from μCT data. In a macro-scale model, representing a mandibular ridge, oblique load of 150 N was applied on the implant-abutment. Maximum principal stress/strain, and shear stress/strain were calculated in the macro- and micro-scale models. Results: Test presented anisotropic material properties. In tests, significantly greater maximum values of Maximum principal stress/strain were calculated in micro-scale model. These values were located at the implant neck area in the macro-scale model and in the proximity of cavities in the micro-scale model respectively. Greater values of shear stress/strain were found in the test along the mandibular horizontal plane. Conclusions: Cortical bone with resorption cavities following undersized drilling showed an impaired load distribution compared with bone without cavities. Subsequently, stress/strain distribution suggests that this bone model is more prone to microdamage, thus delaying the healing process.
AB - Purpose: The aim of this multi-scale in silico study was to evaluate the influence of resorption cavities on the mechanical properties and load distribution in cortical bone after implant placement with two different drilling protocols. Material and methods: Two different micro-scale bone structures were assessed: cortical bone models with cavities (test) and without cavities (control) were designed from μCT data. In a macro-scale model, representing a mandibular ridge, oblique load of 150 N was applied on the implant-abutment. Maximum principal stress/strain, and shear stress/strain were calculated in the macro- and micro-scale models. Results: Test presented anisotropic material properties. In tests, significantly greater maximum values of Maximum principal stress/strain were calculated in micro-scale model. These values were located at the implant neck area in the macro-scale model and in the proximity of cavities in the micro-scale model respectively. Greater values of shear stress/strain were found in the test along the mandibular horizontal plane. Conclusions: Cortical bone with resorption cavities following undersized drilling showed an impaired load distribution compared with bone without cavities. Subsequently, stress/strain distribution suggests that this bone model is more prone to microdamage, thus delaying the healing process.
UR - http://www.scopus.com/inward/record.url?scp=85076459832&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85076459832&partnerID=8YFLogxK
U2 - 10.1016/j.jmbbm.2019.103598
DO - 10.1016/j.jmbbm.2019.103598
M3 - Article
C2 - 32090927
AN - SCOPUS:85076459832
SN - 1751-6161
VL - 103
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
M1 - 103598
ER -