Influence of a flow obstacle on the occurrence of burnout in boiling two-phase upward flow within a vertical annular channel

Shoji Mori, T. Fukano

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

When a flow obstruction such as a cylindrical spacer is set in a boiling two-phase flow within an annular channel, the inner tube of which is used as a heater, the temperature on the surface of the heating tube is severely affected by its existence. In some cases, the cylindrical spacer has a cooling effect, and in the other cases it causes the dryout of the cooling water film on the heating surface resulting in the burnout of the heating tube. In the present paper, we have focused our attention on the influence of a flow obstacle on the occurrence of burnout of the heating tube in boiling two-phase flow. The results are summarized as follows:(1) When the heat flux approaches the burnout condition, the wall temperature on the heating tube fluctuates with a large amplitude. And once the wall temperature exceeds the Leidenfrost temperature, the burnout occurs without exception.(2) The trigger of dryout of the water film which causes the burnout is not the nucleate boiling but the evaporation of the base film between disturbance waves.(3) The burnout never occurs at the downstream side of the spacer. This is because the dryout area downstream of the spacer is rewetted easily by the disturbance waves.

Original languageEnglish
Pages (from-to)49-63
Number of pages15
JournalNuclear Engineering and Design
Volume225
Issue number1
DOIs
Publication statusPublished - Oct 1 2003

Fingerprint

burnout
two phase flow
Two phase flow
boiling
Boiling liquids
occurrences
heating
Heating
spacers
tubes
wall temperature
temperature
disturbances
disturbance
Temperature
Nucleate boiling
cooling water
nucleate boiling
Cooling water
liquid cooling

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics
  • Materials Science(all)
  • Nuclear Energy and Engineering
  • Safety, Risk, Reliability and Quality
  • Waste Management and Disposal
  • Mechanical Engineering

Cite this

Influence of a flow obstacle on the occurrence of burnout in boiling two-phase upward flow within a vertical annular channel. / Mori, Shoji; Fukano, T.

In: Nuclear Engineering and Design, Vol. 225, No. 1, 01.10.2003, p. 49-63.

Research output: Contribution to journalArticle

@article{73bcb4808fec48fea373d08879e7e8d9,
title = "Influence of a flow obstacle on the occurrence of burnout in boiling two-phase upward flow within a vertical annular channel",
abstract = "When a flow obstruction such as a cylindrical spacer is set in a boiling two-phase flow within an annular channel, the inner tube of which is used as a heater, the temperature on the surface of the heating tube is severely affected by its existence. In some cases, the cylindrical spacer has a cooling effect, and in the other cases it causes the dryout of the cooling water film on the heating surface resulting in the burnout of the heating tube. In the present paper, we have focused our attention on the influence of a flow obstacle on the occurrence of burnout of the heating tube in boiling two-phase flow. The results are summarized as follows:(1) When the heat flux approaches the burnout condition, the wall temperature on the heating tube fluctuates with a large amplitude. And once the wall temperature exceeds the Leidenfrost temperature, the burnout occurs without exception.(2) The trigger of dryout of the water film which causes the burnout is not the nucleate boiling but the evaporation of the base film between disturbance waves.(3) The burnout never occurs at the downstream side of the spacer. This is because the dryout area downstream of the spacer is rewetted easily by the disturbance waves.",
author = "Shoji Mori and T. Fukano",
year = "2003",
month = "10",
day = "1",
doi = "10.1016/S0029-5493(03)00136-5",
language = "English",
volume = "225",
pages = "49--63",
journal = "Nuclear Engineering and Design",
issn = "0029-5493",
publisher = "Elsevier BV",
number = "1",

}

TY - JOUR

T1 - Influence of a flow obstacle on the occurrence of burnout in boiling two-phase upward flow within a vertical annular channel

AU - Mori, Shoji

AU - Fukano, T.

PY - 2003/10/1

Y1 - 2003/10/1

N2 - When a flow obstruction such as a cylindrical spacer is set in a boiling two-phase flow within an annular channel, the inner tube of which is used as a heater, the temperature on the surface of the heating tube is severely affected by its existence. In some cases, the cylindrical spacer has a cooling effect, and in the other cases it causes the dryout of the cooling water film on the heating surface resulting in the burnout of the heating tube. In the present paper, we have focused our attention on the influence of a flow obstacle on the occurrence of burnout of the heating tube in boiling two-phase flow. The results are summarized as follows:(1) When the heat flux approaches the burnout condition, the wall temperature on the heating tube fluctuates with a large amplitude. And once the wall temperature exceeds the Leidenfrost temperature, the burnout occurs without exception.(2) The trigger of dryout of the water film which causes the burnout is not the nucleate boiling but the evaporation of the base film between disturbance waves.(3) The burnout never occurs at the downstream side of the spacer. This is because the dryout area downstream of the spacer is rewetted easily by the disturbance waves.

AB - When a flow obstruction such as a cylindrical spacer is set in a boiling two-phase flow within an annular channel, the inner tube of which is used as a heater, the temperature on the surface of the heating tube is severely affected by its existence. In some cases, the cylindrical spacer has a cooling effect, and in the other cases it causes the dryout of the cooling water film on the heating surface resulting in the burnout of the heating tube. In the present paper, we have focused our attention on the influence of a flow obstacle on the occurrence of burnout of the heating tube in boiling two-phase flow. The results are summarized as follows:(1) When the heat flux approaches the burnout condition, the wall temperature on the heating tube fluctuates with a large amplitude. And once the wall temperature exceeds the Leidenfrost temperature, the burnout occurs without exception.(2) The trigger of dryout of the water film which causes the burnout is not the nucleate boiling but the evaporation of the base film between disturbance waves.(3) The burnout never occurs at the downstream side of the spacer. This is because the dryout area downstream of the spacer is rewetted easily by the disturbance waves.

UR - http://www.scopus.com/inward/record.url?scp=0141707644&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0141707644&partnerID=8YFLogxK

U2 - 10.1016/S0029-5493(03)00136-5

DO - 10.1016/S0029-5493(03)00136-5

M3 - Article

VL - 225

SP - 49

EP - 63

JO - Nuclear Engineering and Design

JF - Nuclear Engineering and Design

SN - 0029-5493

IS - 1

ER -