Influence of the parameters of several pulse sequences on the image contrast

comparison between the two major contrast media

Tomohiro Nakayama, Kengo Yoshimitsu, Hiroshi Honda

Research output: Contribution to journalArticle

Abstract

We compared the influences of the parameters of several pulse sequences using two major commercially available gadolinium (Gd) contrast media for MR imaging. The phantom of Gd solutions of various concentration (0.1 - 10mmol/L) was prepared, and was scanned with a 1.5T clinical MR unit, using a spin-echo T1-weighted sequence, 2DFLASH, 3DFLASH, and 3DVIBE. The signal intensity was measured and the contrast enhancement ratio (CER) was calculated and plotted as a function of Gd concentration. The results were compared between the pulse sequences, and between the contrast media as well. Both 3DFLASH and 3DVIBE showed higher CER than other two sequences, showing similar CER curve configuration. There was no significant difference both in CER value and CER curve configuration between the two contrast media for each pulse sequence.

Original languageEnglish
Pages (from-to)90-93
Number of pages4
JournalFukuoka igaku zasshi = Hukuoka acta medica
Volume99
Issue number4
Publication statusPublished - Jan 1 2008

Fingerprint

Gadolinium
Contrast Media

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

Influence of the parameters of several pulse sequences on the image contrast : comparison between the two major contrast media. / Nakayama, Tomohiro; Yoshimitsu, Kengo; Honda, Hiroshi.

In: Fukuoka igaku zasshi = Hukuoka acta medica, Vol. 99, No. 4, 01.01.2008, p. 90-93.

Research output: Contribution to journalArticle

@article{e32233d6df5c4a4db892adf16b0ef739,
title = "Influence of the parameters of several pulse sequences on the image contrast: comparison between the two major contrast media",
abstract = "We compared the influences of the parameters of several pulse sequences using two major commercially available gadolinium (Gd) contrast media for MR imaging. The phantom of Gd solutions of various concentration (0.1 - 10mmol/L) was prepared, and was scanned with a 1.5T clinical MR unit, using a spin-echo T1-weighted sequence, 2DFLASH, 3DFLASH, and 3DVIBE. The signal intensity was measured and the contrast enhancement ratio (CER) was calculated and plotted as a function of Gd concentration. The results were compared between the pulse sequences, and between the contrast media as well. Both 3DFLASH and 3DVIBE showed higher CER than other two sequences, showing similar CER curve configuration. There was no significant difference both in CER value and CER curve configuration between the two contrast media for each pulse sequence.",
author = "Tomohiro Nakayama and Kengo Yoshimitsu and Hiroshi Honda",
year = "2008",
month = "1",
day = "1",
language = "English",
volume = "99",
pages = "90--93",
journal = "Fukuoka Acta Medica",
issn = "0016-254X",
publisher = "福岡医学会",
number = "4",

}

TY - JOUR

T1 - Influence of the parameters of several pulse sequences on the image contrast

T2 - comparison between the two major contrast media

AU - Nakayama, Tomohiro

AU - Yoshimitsu, Kengo

AU - Honda, Hiroshi

PY - 2008/1/1

Y1 - 2008/1/1

N2 - We compared the influences of the parameters of several pulse sequences using two major commercially available gadolinium (Gd) contrast media for MR imaging. The phantom of Gd solutions of various concentration (0.1 - 10mmol/L) was prepared, and was scanned with a 1.5T clinical MR unit, using a spin-echo T1-weighted sequence, 2DFLASH, 3DFLASH, and 3DVIBE. The signal intensity was measured and the contrast enhancement ratio (CER) was calculated and plotted as a function of Gd concentration. The results were compared between the pulse sequences, and between the contrast media as well. Both 3DFLASH and 3DVIBE showed higher CER than other two sequences, showing similar CER curve configuration. There was no significant difference both in CER value and CER curve configuration between the two contrast media for each pulse sequence.

AB - We compared the influences of the parameters of several pulse sequences using two major commercially available gadolinium (Gd) contrast media for MR imaging. The phantom of Gd solutions of various concentration (0.1 - 10mmol/L) was prepared, and was scanned with a 1.5T clinical MR unit, using a spin-echo T1-weighted sequence, 2DFLASH, 3DFLASH, and 3DVIBE. The signal intensity was measured and the contrast enhancement ratio (CER) was calculated and plotted as a function of Gd concentration. The results were compared between the pulse sequences, and between the contrast media as well. Both 3DFLASH and 3DVIBE showed higher CER than other two sequences, showing similar CER curve configuration. There was no significant difference both in CER value and CER curve configuration between the two contrast media for each pulse sequence.

UR - http://www.scopus.com/inward/record.url?scp=51449085369&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=51449085369&partnerID=8YFLogxK

M3 - Article

VL - 99

SP - 90

EP - 93

JO - Fukuoka Acta Medica

JF - Fukuoka Acta Medica

SN - 0016-254X

IS - 4

ER -