Infrequent physician use of implantable cardioverter-defibrillators risks patient safety

Stephen Lyman, Art Sedrakyan, Huong Do, Renee Razzano, Alvin I. Mushlin

Research output: Contribution to journalArticlepeer-review

15 Citations (Scopus)

Abstract

Context: Implantable cardioverter-defibrillators (ICDs) have diffused rapidly into clinical practice with little evaluation of their real-world effectiveness. Objectives: To determine the effect of the adoption of ICD on patient safety, particularly with respect to physician volume and early outcomes. Design: Retrospective cohort of all ICD implantations in New York state from 1997 to 2006, with follow-up at 90 days and 1 year. Setting: New York state non-federal hospital discharges in which an ICD was implanted during the admission. Patients were followed forward for 1 year for subsequent admissions. Patients: New York state residents undergoing ICD implantation. Main outcome measures: Effects of annual and career ICD implantation volume on 90-day complication, readmission, reprogramming, mortality and revision of the ICD within 1 year. Results: This cohort (N=38 992) represents a period of rapid adoption and implementation of this new technology, with frequency more than tripling between 1997 and 2006. We identified 6439 (16.5%) postimplantation complications and 1093 (2.8%) deaths within 90 days of implantation. The majority (73.4%) of physicians implanted one or fewer ICDs per year, and 11.0% of all implantations were performed by these very-low-volume operators. Patients treated by very-lowvolume operators were more likely to die (RR=1.8, 95% CI 1.3 to 2.4) or experience cardiac complications (RR=4.7, 95% CI 3.3 to 6.8) even after the adjustment for case mix compared to operators who frequently performed ICD implantation. Conclusions: These findings suggest a need for safe and effective implementation strategies for new medical technologies, which minimize patient risk due to rapid diffusion among inexperienced providers and assure that the intended benefit can be maximised rapidly.

Original languageEnglish
Pages (from-to)1655-1660
Number of pages6
JournalHeart
Volume97
Issue number20
DOIs
Publication statusPublished - Oct 1 2011
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine

Fingerprint Dive into the research topics of 'Infrequent physician use of implantable cardioverter-defibrillators risks patient safety'. Together they form a unique fingerprint.

Cite this