Abstract

Artifact often mingles with the EEG (electroencephalogram). It makes difficult to make out the intrinsic signal. The aim of this study is removal of the motion artifact causing subjects constrained. First, head movements are measured by an accelerometer and EEG is decomposed by ICA (independent component analysis). Next, the correlation coefficient between ICs (independent components) and value of accelerometer is calculated, and ICs correlated closely with each value of three-axis acceleration and angular velocity remove. Number of removed ICs are changed automatically by the condition of artifact contamination. Last, the non-artifact EEG is reconstructed by the remainder ICs. The removal method used for 5 seconds EEG divided from 30 seconds. Subjects were imposed task that moving head with closed eyes to inspect alpha band. As a result, motion power decreased and alpha band increased relatively. So this method effects on reduction of artifact influence.

Original languageEnglish
Pages (from-to)O-359-O-360
JournalTransactions of Japanese Society for Medical and Biological Engineering
Volume52
DOIs
Publication statusPublished - Aug 17 2014

Fingerprint

Electroencephalography
Accelerometers
Inspection
Independent component analysis
Angular velocity
Contamination

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering

Cite this

@article{2e1ebe4ec0774099956f8188a327adff,
title = "Inspection of the motion artifact removal method from the EEG by using accelerometer",
abstract = "Artifact often mingles with the EEG (electroencephalogram). It makes difficult to make out the intrinsic signal. The aim of this study is removal of the motion artifact causing subjects constrained. First, head movements are measured by an accelerometer and EEG is decomposed by ICA (independent component analysis). Next, the correlation coefficient between ICs (independent components) and value of accelerometer is calculated, and ICs correlated closely with each value of three-axis acceleration and angular velocity remove. Number of removed ICs are changed automatically by the condition of artifact contamination. Last, the non-artifact EEG is reconstructed by the remainder ICs. The removal method used for 5 seconds EEG divided from 30 seconds. Subjects were imposed task that moving head with closed eyes to inspect alpha band. As a result, motion power decreased and alpha band increased relatively. So this method effects on reduction of artifact influence.",
author = "Kazuki Onikura and Keiji Iramina",
year = "2014",
month = "8",
day = "17",
doi = "10.11239/jsmbe.52.O-359",
language = "English",
volume = "52",
pages = "O--359--O--360",
journal = "BME = Bio medical engineering / henshu, Nihon ME Gakkai",
issn = "1347-443X",
publisher = "Japanese Society for Medical and Biological Engineering",

}

TY - JOUR

T1 - Inspection of the motion artifact removal method from the EEG by using accelerometer

AU - Onikura, Kazuki

AU - Iramina, Keiji

PY - 2014/8/17

Y1 - 2014/8/17

N2 - Artifact often mingles with the EEG (electroencephalogram). It makes difficult to make out the intrinsic signal. The aim of this study is removal of the motion artifact causing subjects constrained. First, head movements are measured by an accelerometer and EEG is decomposed by ICA (independent component analysis). Next, the correlation coefficient between ICs (independent components) and value of accelerometer is calculated, and ICs correlated closely with each value of three-axis acceleration and angular velocity remove. Number of removed ICs are changed automatically by the condition of artifact contamination. Last, the non-artifact EEG is reconstructed by the remainder ICs. The removal method used for 5 seconds EEG divided from 30 seconds. Subjects were imposed task that moving head with closed eyes to inspect alpha band. As a result, motion power decreased and alpha band increased relatively. So this method effects on reduction of artifact influence.

AB - Artifact often mingles with the EEG (electroencephalogram). It makes difficult to make out the intrinsic signal. The aim of this study is removal of the motion artifact causing subjects constrained. First, head movements are measured by an accelerometer and EEG is decomposed by ICA (independent component analysis). Next, the correlation coefficient between ICs (independent components) and value of accelerometer is calculated, and ICs correlated closely with each value of three-axis acceleration and angular velocity remove. Number of removed ICs are changed automatically by the condition of artifact contamination. Last, the non-artifact EEG is reconstructed by the remainder ICs. The removal method used for 5 seconds EEG divided from 30 seconds. Subjects were imposed task that moving head with closed eyes to inspect alpha band. As a result, motion power decreased and alpha band increased relatively. So this method effects on reduction of artifact influence.

UR - http://www.scopus.com/inward/record.url?scp=84939434108&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84939434108&partnerID=8YFLogxK

U2 - 10.11239/jsmbe.52.O-359

DO - 10.11239/jsmbe.52.O-359

M3 - Article

AN - SCOPUS:84939434108

VL - 52

SP - O-359-O-360

JO - BME = Bio medical engineering / henshu, Nihon ME Gakkai

JF - BME = Bio medical engineering / henshu, Nihon ME Gakkai

SN - 1347-443X

ER -