Investigation of a practical patient dose index for assessment of patient organ dose from cone-beam computed tomography in radiation therapy using a Monte Carlo simulation

H. Kamezawa, Hidetaka Arimura, H. Arakawa, N. Kameda

Research output: Contribution to journalArticle

Abstract

The purpose of this study was to investigate a practical patient dose index for assessing the patient organ dose from a conebeam computed tomography (CBCT) scan by comparing eight dose indices, i.e. CTDI100, CTDIIEC, CTDI, midpoint doses f(0)PMMA for a cylindrical polymethyl methacrylate (PMMA) phantom, f(0)Ap for an anthropomorphic phantom and f(0)Pat for a prostate cancer patient, as well as the conventional size specific dose estimations (SSDEconv) and modified SSDE (SSDEmod), with organ dose for the prostate (ODprost) obtained via Monte Carlo (MC) simulation. The ODprost was the reference dose used to find the practical dose index at the center of the pelvic region of a prostate cancer patient. The smallest error rate with respect to the ODprost of 19.3 mGy (reference) among eight dose indices was 5% for f(0)Pat. The practical patient dose index was the f(0)Pat, which showed the smallest error with respect to the reference dose.

Original languageEnglish
Pages (from-to)333-342
Number of pages10
JournalRadiation Protection Dosimetry
Volume181
Issue number4
DOIs
Publication statusPublished - Nov 1 2018

Fingerprint

Cone-Beam Computed Tomography
organs
radiation therapy
cones
Radiotherapy
tomography
dosage
Prostate
Polymethyl Methacrylate
simulation
Prostatic Neoplasms
Pelvis
polymethyl methacrylate
Tomography
cancer

All Science Journal Classification (ASJC) codes

  • Radiological and Ultrasound Technology
  • Radiation
  • Radiology Nuclear Medicine and imaging
  • Public Health, Environmental and Occupational Health

Cite this

@article{b022fe9d77c5482eb6b82babaad326a6,
title = "Investigation of a practical patient dose index for assessment of patient organ dose from cone-beam computed tomography in radiation therapy using a Monte Carlo simulation",
abstract = "The purpose of this study was to investigate a practical patient dose index for assessing the patient organ dose from a conebeam computed tomography (CBCT) scan by comparing eight dose indices, i.e. CTDI100, CTDIIEC, CTDI∞, midpoint doses f(0)PMMA for a cylindrical polymethyl methacrylate (PMMA) phantom, f(0)Ap for an anthropomorphic phantom and f(0)Pat for a prostate cancer patient, as well as the conventional size specific dose estimations (SSDEconv) and modified SSDE (SSDEmod), with organ dose for the prostate (ODprost) obtained via Monte Carlo (MC) simulation. The ODprost was the reference dose used to find the practical dose index at the center of the pelvic region of a prostate cancer patient. The smallest error rate with respect to the ODprost of 19.3 mGy (reference) among eight dose indices was 5{\%} for f(0)Pat. The practical patient dose index was the f(0)Pat, which showed the smallest error with respect to the reference dose.",
author = "H. Kamezawa and Hidetaka Arimura and H. Arakawa and N. Kameda",
year = "2018",
month = "11",
day = "1",
doi = "10.1093/RPD/NCY032",
language = "English",
volume = "181",
pages = "333--342",
journal = "Radiation Protection Dosimetry",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "4",

}

TY - JOUR

T1 - Investigation of a practical patient dose index for assessment of patient organ dose from cone-beam computed tomography in radiation therapy using a Monte Carlo simulation

AU - Kamezawa, H.

AU - Arimura, Hidetaka

AU - Arakawa, H.

AU - Kameda, N.

PY - 2018/11/1

Y1 - 2018/11/1

N2 - The purpose of this study was to investigate a practical patient dose index for assessing the patient organ dose from a conebeam computed tomography (CBCT) scan by comparing eight dose indices, i.e. CTDI100, CTDIIEC, CTDI∞, midpoint doses f(0)PMMA for a cylindrical polymethyl methacrylate (PMMA) phantom, f(0)Ap for an anthropomorphic phantom and f(0)Pat for a prostate cancer patient, as well as the conventional size specific dose estimations (SSDEconv) and modified SSDE (SSDEmod), with organ dose for the prostate (ODprost) obtained via Monte Carlo (MC) simulation. The ODprost was the reference dose used to find the practical dose index at the center of the pelvic region of a prostate cancer patient. The smallest error rate with respect to the ODprost of 19.3 mGy (reference) among eight dose indices was 5% for f(0)Pat. The practical patient dose index was the f(0)Pat, which showed the smallest error with respect to the reference dose.

AB - The purpose of this study was to investigate a practical patient dose index for assessing the patient organ dose from a conebeam computed tomography (CBCT) scan by comparing eight dose indices, i.e. CTDI100, CTDIIEC, CTDI∞, midpoint doses f(0)PMMA for a cylindrical polymethyl methacrylate (PMMA) phantom, f(0)Ap for an anthropomorphic phantom and f(0)Pat for a prostate cancer patient, as well as the conventional size specific dose estimations (SSDEconv) and modified SSDE (SSDEmod), with organ dose for the prostate (ODprost) obtained via Monte Carlo (MC) simulation. The ODprost was the reference dose used to find the practical dose index at the center of the pelvic region of a prostate cancer patient. The smallest error rate with respect to the ODprost of 19.3 mGy (reference) among eight dose indices was 5% for f(0)Pat. The practical patient dose index was the f(0)Pat, which showed the smallest error with respect to the reference dose.

UR - http://www.scopus.com/inward/record.url?scp=85056404209&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85056404209&partnerID=8YFLogxK

U2 - 10.1093/RPD/NCY032

DO - 10.1093/RPD/NCY032

M3 - Article

C2 - 29506291

AN - SCOPUS:85056404209

VL - 181

SP - 333

EP - 342

JO - Radiation Protection Dosimetry

JF - Radiation Protection Dosimetry

SN - 0144-8420

IS - 4

ER -