TY - JOUR
T1 - Kinematic analysis of healthy hips during weight-bearing activities by 3D-to-2D model-to-image registration technique
AU - Hara, Daisuke
AU - Nakashima, Yasuharu
AU - Hamai, Satoshi
AU - Higaki, Hidehiko
AU - Ikebe, Satoru
AU - Shimoto, Takeshi
AU - Hirata, Masanobu
AU - Kanazawa, Masayuki
AU - Kohno, Yusuke
AU - Iwamoto, Yukihide
N1 - Publisher Copyright:
© 2014 Daisuke Hara et al.
PY - 2014
Y1 - 2014
N2 - Dynamic hip kinematics during weight-bearing activities were analyzed for six healthy subjects. Continuous X-ray images of gait, chair-rising, squatting, and twisting were taken using a flat panel X-ray detector. Digitally reconstructed radiographic images were used for 3D-to-2D model-to-image registration technique. The root-mean-square errors associated with tracking the pelvis and femur were less than 0.3 mm and 0.3° for translations and rotations. For gait, chair-rising, and squatting, the maximum hip flexion angles averaged 29.6°, 81.3°, and 102.4°, respectively. The pelvis was tilted anteriorly around 4.4° on average during full gait cycle. For chair-rising and squatting, the maximum absolute value of anterior/posterior pelvic tilt averaged 12.4°/11.7° and 10.7°/10.8°, respectively. Hip flexion peaked on the way of movement due to further anterior pelvic tilt during both chair-rising and squatting. For twisting, the maximum absolute value of hip internal/external rotation averaged 29.2°/30.7°. This study revealed activity dependent kinematics of healthy hip joints with coordinated pelvic and femoral dynamic movements. Kinematics' data during activities of daily living may provide important insight as to the evaluating kinematics of pathological and reconstructed hips.
AB - Dynamic hip kinematics during weight-bearing activities were analyzed for six healthy subjects. Continuous X-ray images of gait, chair-rising, squatting, and twisting were taken using a flat panel X-ray detector. Digitally reconstructed radiographic images were used for 3D-to-2D model-to-image registration technique. The root-mean-square errors associated with tracking the pelvis and femur were less than 0.3 mm and 0.3° for translations and rotations. For gait, chair-rising, and squatting, the maximum hip flexion angles averaged 29.6°, 81.3°, and 102.4°, respectively. The pelvis was tilted anteriorly around 4.4° on average during full gait cycle. For chair-rising and squatting, the maximum absolute value of anterior/posterior pelvic tilt averaged 12.4°/11.7° and 10.7°/10.8°, respectively. Hip flexion peaked on the way of movement due to further anterior pelvic tilt during both chair-rising and squatting. For twisting, the maximum absolute value of hip internal/external rotation averaged 29.2°/30.7°. This study revealed activity dependent kinematics of healthy hip joints with coordinated pelvic and femoral dynamic movements. Kinematics' data during activities of daily living may provide important insight as to the evaluating kinematics of pathological and reconstructed hips.
UR - http://www.scopus.com/inward/record.url?scp=84915749097&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84915749097&partnerID=8YFLogxK
U2 - 10.1155/2014/457573
DO - 10.1155/2014/457573
M3 - Article
C2 - 25506056
AN - SCOPUS:84915749097
SN - 2314-6133
VL - 2014
JO - BioMed Research International
JF - BioMed Research International
M1 - 457573
ER -