T1 - Late results after mitral valve replacement with bileaflet mechanical prosthesis in children
T2 - Evaluation of prosthesis-patient mismatch
AU - Masuda, Munetaka
AU - Kado, Hideaki
AU - Tatewaki, Hideki
AU - Shiokawa, Yuichiro
AU - Yasui, Hisataka
PY - 2004/3
Y1 - 2004/3
N2 - Background. Mechanical prosthesis is the choice of valve at the mitral position in children, although re-replacement of prostheses because of prosthesis-patient mismatch is almost inevitable when prostheses were implanted in small children. The methods to predict prosthesis-patient mismatch as a result of patients' somatic growth or pannus formation in children by noninvasive methods have not been well established. Methods. Thirty-two children underwent mitral valve replacement with 37 bileaflet mechanical prostheses (26 St. Jude Medical prosthetic valves, and 11 CarboMedics prosthetic valves) and were followed up a mean of 6.8 years (maximum 18.3 years) with a complete follow-up rate of 94%. Results. There were no operative deaths and 5 late deaths. Re-replacement of mitral valve because of prosthesis-patient mismatch was required in 5 patients. Freedom from valve-related events and re-replacement of mitral valve at 15 years were 32% ± 23% and 54% ± 18%, respectively. Actuarial survival rate was 63% ± 19% at 15 years. Prosthetic valve orifice area index (manufactured geometric prosthetic valve area divided by patient's body surface area) was well correlated with maximum transprosthesis flow velocity estimated by Doppler echocardiography during follow-up, whereas valve orifice area index had no significant correlation with pulmonary artery wedge pressure assessed by cardiac catheterization. Maximum transprosthesis flow velocity had a significant correlation with pulmonary artery wedge pressure. Conclusions. Valve orifice area index itself was not a reliable index to predict prosthesis-patient mismatch. Maximum transprosthesis flow velocity was a useful index to predict pulmonary artery wedge. Invasive cardiac catheterization to determine re-replacement of the prosthesis should be considered when maximum transprosthesis flow velocity exceeds 270 cm/s.
AB - Background. Mechanical prosthesis is the choice of valve at the mitral position in children, although re-replacement of prostheses because of prosthesis-patient mismatch is almost inevitable when prostheses were implanted in small children. The methods to predict prosthesis-patient mismatch as a result of patients' somatic growth or pannus formation in children by noninvasive methods have not been well established. Methods. Thirty-two children underwent mitral valve replacement with 37 bileaflet mechanical prostheses (26 St. Jude Medical prosthetic valves, and 11 CarboMedics prosthetic valves) and were followed up a mean of 6.8 years (maximum 18.3 years) with a complete follow-up rate of 94%. Results. There were no operative deaths and 5 late deaths. Re-replacement of mitral valve because of prosthesis-patient mismatch was required in 5 patients. Freedom from valve-related events and re-replacement of mitral valve at 15 years were 32% ± 23% and 54% ± 18%, respectively. Actuarial survival rate was 63% ± 19% at 15 years. Prosthetic valve orifice area index (manufactured geometric prosthetic valve area divided by patient's body surface area) was well correlated with maximum transprosthesis flow velocity estimated by Doppler echocardiography during follow-up, whereas valve orifice area index had no significant correlation with pulmonary artery wedge pressure assessed by cardiac catheterization. Maximum transprosthesis flow velocity had a significant correlation with pulmonary artery wedge pressure. Conclusions. Valve orifice area index itself was not a reliable index to predict prosthesis-patient mismatch. Maximum transprosthesis flow velocity was a useful index to predict pulmonary artery wedge. Invasive cardiac catheterization to determine re-replacement of the prosthesis should be considered when maximum transprosthesis flow velocity exceeds 270 cm/s.
UR - http://www.scopus.com/inward/record.url?scp=1442300132&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=1442300132&partnerID=8YFLogxK
U2 - 10.1016/j.athoracsur.2003.09.066
DO - 10.1016/j.athoracsur.2003.09.066
M3 - Article
C2 - 14992898
AN - SCOPUS:1442300132
VL - 77
SP - 913
EP - 917
JO - Annals of Thoracic Surgery
JF - Annals of Thoracic Surgery
SN - 0003-4975
IS - 3
ER -