Local current density measurement using a Rogowski probe in Tokyo Spherical Tokamak-2

H. Furui, Y. Nagashima, Y. Takase, A. Ejiri, H. Kakuda, M. Sonehara, T. Oosako, N. Tsujii, J. Hiratsuka, K. Imamura, T. Inada, K. Nakamura, A. Nakanishi, T. Shinya, H. Togashi, S. Tsuda, T. Wakatsuki, T. Yamaguchi

    Research output: Contribution to journalArticle

    5 Citations (Scopus)

    Abstract

    A Rogowski probe consisting of a small multi-layer Rogowski coil, five magnetic pick-up coils, and a Langmuir probe was developed to measure the local current density and its direction. It can be moved along the major radius and can be turned around its axis. This probe was used to measure the current density profile near the last closed flux surface of Ohmic plasmas in Tokyo Spherical Tokamak-2. The current density profile was measured successfully with a signal to noise ratio of greater than 20.

    Original languageEnglish
    Article number11D813
    JournalReview of Scientific Instruments
    Volume85
    Issue number11
    DOIs
    Publication statusPublished - Nov 2014

    Fingerprint

    Electric current measurement
    Current density
    current density
    probes
    magnetic coils
    Langmuir probes
    electrostatic probes
    profiles
    Signal to noise ratio
    signal to noise ratios
    coils
    Fluxes
    Plasmas
    radii

    All Science Journal Classification (ASJC) codes

    • Instrumentation

    Cite this

    Local current density measurement using a Rogowski probe in Tokyo Spherical Tokamak-2. / Furui, H.; Nagashima, Y.; Takase, Y.; Ejiri, A.; Kakuda, H.; Sonehara, M.; Oosako, T.; Tsujii, N.; Hiratsuka, J.; Imamura, K.; Inada, T.; Nakamura, K.; Nakanishi, A.; Shinya, T.; Togashi, H.; Tsuda, S.; Wakatsuki, T.; Yamaguchi, T.

    In: Review of Scientific Instruments, Vol. 85, No. 11, 11D813, 11.2014.

    Research output: Contribution to journalArticle

    Furui, H, Nagashima, Y, Takase, Y, Ejiri, A, Kakuda, H, Sonehara, M, Oosako, T, Tsujii, N, Hiratsuka, J, Imamura, K, Inada, T, Nakamura, K, Nakanishi, A, Shinya, T, Togashi, H, Tsuda, S, Wakatsuki, T & Yamaguchi, T 2014, 'Local current density measurement using a Rogowski probe in Tokyo Spherical Tokamak-2', Review of Scientific Instruments, vol. 85, no. 11, 11D813. https://doi.org/10.1063/1.4887277
    Furui, H. ; Nagashima, Y. ; Takase, Y. ; Ejiri, A. ; Kakuda, H. ; Sonehara, M. ; Oosako, T. ; Tsujii, N. ; Hiratsuka, J. ; Imamura, K. ; Inada, T. ; Nakamura, K. ; Nakanishi, A. ; Shinya, T. ; Togashi, H. ; Tsuda, S. ; Wakatsuki, T. ; Yamaguchi, T. / Local current density measurement using a Rogowski probe in Tokyo Spherical Tokamak-2. In: Review of Scientific Instruments. 2014 ; Vol. 85, No. 11.
    @article{d98c13575f6e4de6b4199aef0becf6d9,
    title = "Local current density measurement using a Rogowski probe in Tokyo Spherical Tokamak-2",
    abstract = "A Rogowski probe consisting of a small multi-layer Rogowski coil, five magnetic pick-up coils, and a Langmuir probe was developed to measure the local current density and its direction. It can be moved along the major radius and can be turned around its axis. This probe was used to measure the current density profile near the last closed flux surface of Ohmic plasmas in Tokyo Spherical Tokamak-2. The current density profile was measured successfully with a signal to noise ratio of greater than 20.",
    author = "H. Furui and Y. Nagashima and Y. Takase and A. Ejiri and H. Kakuda and M. Sonehara and T. Oosako and N. Tsujii and J. Hiratsuka and K. Imamura and T. Inada and K. Nakamura and A. Nakanishi and T. Shinya and H. Togashi and S. Tsuda and T. Wakatsuki and T. Yamaguchi",
    year = "2014",
    month = "11",
    doi = "10.1063/1.4887277",
    language = "English",
    volume = "85",
    journal = "Review of Scientific Instruments",
    issn = "0034-6748",
    publisher = "American Institute of Physics Publising LLC",
    number = "11",

    }

    TY - JOUR

    T1 - Local current density measurement using a Rogowski probe in Tokyo Spherical Tokamak-2

    AU - Furui, H.

    AU - Nagashima, Y.

    AU - Takase, Y.

    AU - Ejiri, A.

    AU - Kakuda, H.

    AU - Sonehara, M.

    AU - Oosako, T.

    AU - Tsujii, N.

    AU - Hiratsuka, J.

    AU - Imamura, K.

    AU - Inada, T.

    AU - Nakamura, K.

    AU - Nakanishi, A.

    AU - Shinya, T.

    AU - Togashi, H.

    AU - Tsuda, S.

    AU - Wakatsuki, T.

    AU - Yamaguchi, T.

    PY - 2014/11

    Y1 - 2014/11

    N2 - A Rogowski probe consisting of a small multi-layer Rogowski coil, five magnetic pick-up coils, and a Langmuir probe was developed to measure the local current density and its direction. It can be moved along the major radius and can be turned around its axis. This probe was used to measure the current density profile near the last closed flux surface of Ohmic plasmas in Tokyo Spherical Tokamak-2. The current density profile was measured successfully with a signal to noise ratio of greater than 20.

    AB - A Rogowski probe consisting of a small multi-layer Rogowski coil, five magnetic pick-up coils, and a Langmuir probe was developed to measure the local current density and its direction. It can be moved along the major radius and can be turned around its axis. This probe was used to measure the current density profile near the last closed flux surface of Ohmic plasmas in Tokyo Spherical Tokamak-2. The current density profile was measured successfully with a signal to noise ratio of greater than 20.

    UR - http://www.scopus.com/inward/record.url?scp=84904438584&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84904438584&partnerID=8YFLogxK

    U2 - 10.1063/1.4887277

    DO - 10.1063/1.4887277

    M3 - Article

    AN - SCOPUS:84904438584

    VL - 85

    JO - Review of Scientific Instruments

    JF - Review of Scientific Instruments

    SN - 0034-6748

    IS - 11

    M1 - 11D813

    ER -