TY - JOUR
T1 - Magnetotelluric transect of Unzen graben, Japan
T2 - conductors associated with normal faults
AU - Triahadini, Agnis
AU - Aizawa, Koki
AU - Teguri, Yoshiko
AU - Koyama, Takao
AU - Tsukamoto, Kaori
AU - Muramatsu, Dan
AU - Chiba, Keita
AU - Uyeshima, Makoto
N1 - Funding Information:
This study was supported by the Ministry of Education, Culture, Sports, Science and Technology (MEXT) of Japan, under its Earthquake and Volcano Hazards Observation and Research Program and KAKENHI (Grant No. 15K17751). AT sincerely thanks the LPDP Scholarship (Indonesian Education Scholarship) for funding her education at Kyushu University.
Funding Information:
We thank forestry officers for granting access to conduct field campaigns. We appreciate S. Matsumoto and H. Shimizu for extensive discussions and suggestions while interpreting the results. We appreciate H. Tsutsumi, M. Ueda, and Geospatial Information Authority of Japan for supplying the fault data. SEVO students Y. Hayashida, K. Takeishi, Y. Yuasa, S. Watanabe, and Y. Odasaki are thanked for their help with the MT survey. Our gratitude goes to Y. Ogawa for supplying 2-D inversion code and W. Siripunvaraporn for supplying his 3-D inversion code. We used the computer systems of the Earthquake and Volcano Information Center of the Earthquake Research Institute, the University of Tokyo. Comments from two anonymous reviewers were helpful in improving the manuscript. This study was supported by the Ministry of Education, Culture, Sports, Science and Technology (MEXT) of Japan, under its Earthquake and Volcano Hazards Observation and Research Program, and funded by JSPS KAKENHI (JP15K17751). AT sincerely thanks the LPDP Scholarship (Indonesian Education Scholarship) for funding her education at Kyushu University.
Publisher Copyright:
© 2019, The Author(s).
PY - 2019/12/1
Y1 - 2019/12/1
N2 - We conducted a broadband magnetotelluric (MT) survey along a north–south transect across Unzen graben, Japan. The MT survey line is located ~ 2 km west of the most recent lava dome and consisted of 27 stations along a 9-km profile. We estimated the 3-D resistivity structure and correlated it with the seismic reflection structure obtained by the same survey line as in the present study. The best-fit resistivity structure shows an upper resistive layer underlain by a moderately conductive layer. The resistive layer, which is interpreted as a cold groundwater zone, is cut by four faults marked by their relatively high conductivity. The underlying layer, which is interpreted as a hydrothermal-water-rich layer, also shows relatively conductive values near the faults. By assuming that the faults are imaged as relatively conductive zones, we infer the dip and depth extent of fracture zones around the faults. Beneath the Chijiwa Fault, which is the longest and most active fault of Unzen graben, the dominant conductor (C1) has a width of 2 km and extends down to below 4 km depth. C1 corresponds to a zone of strong seismic reflection and is located close to one of the pressure sources causing surface deformation. In this study, we interpret C1 as a network of fractures generated by the Chijiwa Fault to which magmatic volatiles are supplied from a deeper pressure source. Given that C1 extends to a greater depth and its resistivity is lower than other conductive zones, it is possible that earthquakes have occurred repeatedly on the Chijiwa Fault. In the center of the study area, we identify a vertically oriented body of high resistivity (R1) that corresponds to a zone of low seismic reflectivity. We interpret R1 as a cooled dyke complex that may have acted as a volcanic conduit.[Figure not available: see fulltext.].
AB - We conducted a broadband magnetotelluric (MT) survey along a north–south transect across Unzen graben, Japan. The MT survey line is located ~ 2 km west of the most recent lava dome and consisted of 27 stations along a 9-km profile. We estimated the 3-D resistivity structure and correlated it with the seismic reflection structure obtained by the same survey line as in the present study. The best-fit resistivity structure shows an upper resistive layer underlain by a moderately conductive layer. The resistive layer, which is interpreted as a cold groundwater zone, is cut by four faults marked by their relatively high conductivity. The underlying layer, which is interpreted as a hydrothermal-water-rich layer, also shows relatively conductive values near the faults. By assuming that the faults are imaged as relatively conductive zones, we infer the dip and depth extent of fracture zones around the faults. Beneath the Chijiwa Fault, which is the longest and most active fault of Unzen graben, the dominant conductor (C1) has a width of 2 km and extends down to below 4 km depth. C1 corresponds to a zone of strong seismic reflection and is located close to one of the pressure sources causing surface deformation. In this study, we interpret C1 as a network of fractures generated by the Chijiwa Fault to which magmatic volatiles are supplied from a deeper pressure source. Given that C1 extends to a greater depth and its resistivity is lower than other conductive zones, it is possible that earthquakes have occurred repeatedly on the Chijiwa Fault. In the center of the study area, we identify a vertically oriented body of high resistivity (R1) that corresponds to a zone of low seismic reflectivity. We interpret R1 as a cooled dyke complex that may have acted as a volcanic conduit.[Figure not available: see fulltext.].
UR - http://www.scopus.com/inward/record.url?scp=85062613334&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85062613334&partnerID=8YFLogxK
U2 - 10.1186/s40623-019-1004-z
DO - 10.1186/s40623-019-1004-z
M3 - Article
AN - SCOPUS:85062613334
SN - 1343-8832
VL - 71
JO - Earth, Planets and Space
JF - Earth, Planets and Space
IS - 1
M1 - 28
ER -