Malfunction mechanism of semiconductor circuit breaker in HVDC power supply system

Seiya Abe, Kentaro Fukushima, Sihun Yang, Mariko Ogawa, Kosuke Nomura, Masahito Shoyama, Tamotsu Ninomiya, Akira Matsumoto, Akiyoshi Fukui, Mikio Yamasaki

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

This paper considers the malfunction mechanism of semiconductor circuit breaker in high voltage DC power supply system (HVDC). In HVDC system, the fast response breaker is required. Semiconductor circuit breaker is paid attention as one of the key technology in HVDC. However, in some condition, the semiconductor circuit is malfunctioned. When malfunction is happened, unexpected large current is flown to the other normal line. In this paper, the malfunction mechanism of semiconductor circuit breaker is considered. It demonstrated by using MATLAB/Simulink. Moreover, the demonstrated results are confirmed by experimentally.

Original languageEnglish
Title of host publication2010 IEEE Energy Conversion Congress and Exposition, ECCE 2010 - Proceedings
Pages3733-3738
Number of pages6
DOIs
Publication statusPublished - 2010
Event2010 2nd IEEE Energy Conversion Congress and Exposition, ECCE 2010 - Atlanta, GA, United States
Duration: Sep 12 2010Sep 16 2010

Other

Other2010 2nd IEEE Energy Conversion Congress and Exposition, ECCE 2010
CountryUnited States
CityAtlanta, GA
Period9/12/109/16/10

Fingerprint

Electric circuit breakers
Electric power systems
Semiconductor materials
MATLAB
Networks (circuits)
Electric potential

All Science Journal Classification (ASJC) codes

  • Energy Engineering and Power Technology
  • Renewable Energy, Sustainability and the Environment

Cite this

Abe, S., Fukushima, K., Yang, S., Ogawa, M., Nomura, K., Shoyama, M., ... Yamasaki, M. (2010). Malfunction mechanism of semiconductor circuit breaker in HVDC power supply system. In 2010 IEEE Energy Conversion Congress and Exposition, ECCE 2010 - Proceedings (pp. 3733-3738). [5617785] https://doi.org/10.1109/ECCE.2010.5617785

Malfunction mechanism of semiconductor circuit breaker in HVDC power supply system. / Abe, Seiya; Fukushima, Kentaro; Yang, Sihun; Ogawa, Mariko; Nomura, Kosuke; Shoyama, Masahito; Ninomiya, Tamotsu; Matsumoto, Akira; Fukui, Akiyoshi; Yamasaki, Mikio.

2010 IEEE Energy Conversion Congress and Exposition, ECCE 2010 - Proceedings. 2010. p. 3733-3738 5617785.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abe, S, Fukushima, K, Yang, S, Ogawa, M, Nomura, K, Shoyama, M, Ninomiya, T, Matsumoto, A, Fukui, A & Yamasaki, M 2010, Malfunction mechanism of semiconductor circuit breaker in HVDC power supply system. in 2010 IEEE Energy Conversion Congress and Exposition, ECCE 2010 - Proceedings., 5617785, pp. 3733-3738, 2010 2nd IEEE Energy Conversion Congress and Exposition, ECCE 2010, Atlanta, GA, United States, 9/12/10. https://doi.org/10.1109/ECCE.2010.5617785
Abe S, Fukushima K, Yang S, Ogawa M, Nomura K, Shoyama M et al. Malfunction mechanism of semiconductor circuit breaker in HVDC power supply system. In 2010 IEEE Energy Conversion Congress and Exposition, ECCE 2010 - Proceedings. 2010. p. 3733-3738. 5617785 https://doi.org/10.1109/ECCE.2010.5617785
Abe, Seiya ; Fukushima, Kentaro ; Yang, Sihun ; Ogawa, Mariko ; Nomura, Kosuke ; Shoyama, Masahito ; Ninomiya, Tamotsu ; Matsumoto, Akira ; Fukui, Akiyoshi ; Yamasaki, Mikio. / Malfunction mechanism of semiconductor circuit breaker in HVDC power supply system. 2010 IEEE Energy Conversion Congress and Exposition, ECCE 2010 - Proceedings. 2010. pp. 3733-3738
@inproceedings{1e3fa9136cff44898bfbb832665d860c,
title = "Malfunction mechanism of semiconductor circuit breaker in HVDC power supply system",
abstract = "This paper considers the malfunction mechanism of semiconductor circuit breaker in high voltage DC power supply system (HVDC). In HVDC system, the fast response breaker is required. Semiconductor circuit breaker is paid attention as one of the key technology in HVDC. However, in some condition, the semiconductor circuit is malfunctioned. When malfunction is happened, unexpected large current is flown to the other normal line. In this paper, the malfunction mechanism of semiconductor circuit breaker is considered. It demonstrated by using MATLAB/Simulink. Moreover, the demonstrated results are confirmed by experimentally.",
author = "Seiya Abe and Kentaro Fukushima and Sihun Yang and Mariko Ogawa and Kosuke Nomura and Masahito Shoyama and Tamotsu Ninomiya and Akira Matsumoto and Akiyoshi Fukui and Mikio Yamasaki",
year = "2010",
doi = "10.1109/ECCE.2010.5617785",
language = "English",
isbn = "9781424452866",
pages = "3733--3738",
booktitle = "2010 IEEE Energy Conversion Congress and Exposition, ECCE 2010 - Proceedings",

}

TY - GEN

T1 - Malfunction mechanism of semiconductor circuit breaker in HVDC power supply system

AU - Abe, Seiya

AU - Fukushima, Kentaro

AU - Yang, Sihun

AU - Ogawa, Mariko

AU - Nomura, Kosuke

AU - Shoyama, Masahito

AU - Ninomiya, Tamotsu

AU - Matsumoto, Akira

AU - Fukui, Akiyoshi

AU - Yamasaki, Mikio

PY - 2010

Y1 - 2010

N2 - This paper considers the malfunction mechanism of semiconductor circuit breaker in high voltage DC power supply system (HVDC). In HVDC system, the fast response breaker is required. Semiconductor circuit breaker is paid attention as one of the key technology in HVDC. However, in some condition, the semiconductor circuit is malfunctioned. When malfunction is happened, unexpected large current is flown to the other normal line. In this paper, the malfunction mechanism of semiconductor circuit breaker is considered. It demonstrated by using MATLAB/Simulink. Moreover, the demonstrated results are confirmed by experimentally.

AB - This paper considers the malfunction mechanism of semiconductor circuit breaker in high voltage DC power supply system (HVDC). In HVDC system, the fast response breaker is required. Semiconductor circuit breaker is paid attention as one of the key technology in HVDC. However, in some condition, the semiconductor circuit is malfunctioned. When malfunction is happened, unexpected large current is flown to the other normal line. In this paper, the malfunction mechanism of semiconductor circuit breaker is considered. It demonstrated by using MATLAB/Simulink. Moreover, the demonstrated results are confirmed by experimentally.

UR - http://www.scopus.com/inward/record.url?scp=78650125264&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78650125264&partnerID=8YFLogxK

U2 - 10.1109/ECCE.2010.5617785

DO - 10.1109/ECCE.2010.5617785

M3 - Conference contribution

AN - SCOPUS:78650125264

SN - 9781424452866

SP - 3733

EP - 3738

BT - 2010 IEEE Energy Conversion Congress and Exposition, ECCE 2010 - Proceedings