Measurement and source localization of middle latency auditory evoked magnetic fields

Takashi Yoshiura, Shoogo Ueno, Keiji Iramina, Kouji Masuda

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Middle latency auditory evoked magnetic fields (MLAEFs) of the human brain were measured with a multi-channel de SQUID system. The positions of the electric sources of Pa and Pb components were estimated and compared with that of the electric sources of N100. The sources of Pa and N100 were estimated at similar positions, whereas the sources of Pb and N100 were estimated in separate areas in the auditory cortex.

Original languageEnglish
Title of host publicationProceedings of the Annual Conference on Engineering in Medicine and Biology
PublisherPubl by IEEE
Pages432-433
Number of pages2
Editionpt 1
ISBN (Print)0780313771
Publication statusPublished - Dec 1 1993
EventProceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Society - San Diego, CA, USA
Duration: Oct 28 1993Oct 31 1993

Publication series

NameProceedings of the Annual Conference on Engineering in Medicine and Biology
Numberpt 1
Volume15
ISSN (Print)0589-1019

Other

OtherProceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
CitySan Diego, CA, USA
Period10/28/9310/31/93

All Science Journal Classification (ASJC) codes

  • Signal Processing
  • Biomedical Engineering
  • Computer Vision and Pattern Recognition
  • Health Informatics

Fingerprint

Dive into the research topics of 'Measurement and source localization of middle latency auditory evoked magnetic fields'. Together they form a unique fingerprint.

Cite this