Measurement of Azz of pd radiative capture at Ed=196MeV

Y. Tameshige, K. Hatanaka, K. Sagara, M. Dozono, Kunihiro Fujita, E. Ihara, T. Kaneda, M. Kato, T. Kawabata, S. Kuroita, Y. Maeda, H. Matsubara, H. Okamura, Y. Sakemi, K. Sekiguchi, Y. Shimizu, T. Sugimoto, A. Tamii, Tomotsugu Wakasa

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

In our previous measurement of pd radiative capture at Ed = 137 and 196MeV, we found an interesting fact that the measured tensor analyzing powers show the relation Axx ≈ Ayy, although calculated Axx and Ayy are apparently different, Axx ≠ Ayy. The measured Ayy agrees fairly well with the 3N calculations, and the measured Axx largely disagrees with calculated Axx. Similar experiments on pd capture have been made at KVI at nearly the same energies of 130-180MeV. The KVI data also support Axx ≈ Ayy relation, but absolute values of Axx and Ayy at KVI are about half of RCNP data. Therefore, we made a new experiment of pd capture at Ed =196MeV. Azz was measured in three different ways, and data analysis is in progress. Preliminary data seem to support our previous data.

Original languageEnglish
Pages (from-to)179-181
Number of pages3
JournalFew-Body Systems
Volume44
Issue number1-4
DOIs
Publication statusPublished - Nov 27 2008

Fingerprint

tensors
energy

All Science Journal Classification (ASJC) codes

  • Atomic and Molecular Physics, and Optics

Cite this

Measurement of Azz of pd radiative capture at Ed=196MeV. / Tameshige, Y.; Hatanaka, K.; Sagara, K.; Dozono, M.; Fujita, Kunihiro; Ihara, E.; Kaneda, T.; Kato, M.; Kawabata, T.; Kuroita, S.; Maeda, Y.; Matsubara, H.; Okamura, H.; Sakemi, Y.; Sekiguchi, K.; Shimizu, Y.; Sugimoto, T.; Tamii, A.; Wakasa, Tomotsugu.

In: Few-Body Systems, Vol. 44, No. 1-4, 27.11.2008, p. 179-181.

Research output: Contribution to journalArticle

Tameshige, Y, Hatanaka, K, Sagara, K, Dozono, M, Fujita, K, Ihara, E, Kaneda, T, Kato, M, Kawabata, T, Kuroita, S, Maeda, Y, Matsubara, H, Okamura, H, Sakemi, Y, Sekiguchi, K, Shimizu, Y, Sugimoto, T, Tamii, A & Wakasa, T 2008, 'Measurement of Azz of pd radiative capture at Ed=196MeV', Few-Body Systems, vol. 44, no. 1-4, pp. 179-181. https://doi.org/10.1007/s00601-008-0285-8
Tameshige Y, Hatanaka K, Sagara K, Dozono M, Fujita K, Ihara E et al. Measurement of Azz of pd radiative capture at Ed=196MeV. Few-Body Systems. 2008 Nov 27;44(1-4):179-181. https://doi.org/10.1007/s00601-008-0285-8
Tameshige, Y. ; Hatanaka, K. ; Sagara, K. ; Dozono, M. ; Fujita, Kunihiro ; Ihara, E. ; Kaneda, T. ; Kato, M. ; Kawabata, T. ; Kuroita, S. ; Maeda, Y. ; Matsubara, H. ; Okamura, H. ; Sakemi, Y. ; Sekiguchi, K. ; Shimizu, Y. ; Sugimoto, T. ; Tamii, A. ; Wakasa, Tomotsugu. / Measurement of Azz of pd radiative capture at Ed=196MeV. In: Few-Body Systems. 2008 ; Vol. 44, No. 1-4. pp. 179-181.
@article{5c2d6cb3cfb14c6897c04f7522614d42,
title = "Measurement of Azz of pd radiative capture at Ed=196MeV",
abstract = "In our previous measurement of pd radiative capture at Ed = 137 and 196MeV, we found an interesting fact that the measured tensor analyzing powers show the relation Axx ≈ Ayy, although calculated Axx and Ayy are apparently different, Axx ≠ Ayy. The measured Ayy agrees fairly well with the 3N calculations, and the measured Axx largely disagrees with calculated Axx. Similar experiments on pd capture have been made at KVI at nearly the same energies of 130-180MeV. The KVI data also support Axx ≈ Ayy relation, but absolute values of Axx and Ayy at KVI are about half of RCNP data. Therefore, we made a new experiment of pd capture at Ed =196MeV. Azz was measured in three different ways, and data analysis is in progress. Preliminary data seem to support our previous data.",
author = "Y. Tameshige and K. Hatanaka and K. Sagara and M. Dozono and Kunihiro Fujita and E. Ihara and T. Kaneda and M. Kato and T. Kawabata and S. Kuroita and Y. Maeda and H. Matsubara and H. Okamura and Y. Sakemi and K. Sekiguchi and Y. Shimizu and T. Sugimoto and A. Tamii and Tomotsugu Wakasa",
year = "2008",
month = "11",
day = "27",
doi = "10.1007/s00601-008-0285-8",
language = "English",
volume = "44",
pages = "179--181",
journal = "Few-Body Systems",
issn = "0177-7963",
publisher = "Springer Wien",
number = "1-4",

}

TY - JOUR

T1 - Measurement of Azz of pd radiative capture at Ed=196MeV

AU - Tameshige, Y.

AU - Hatanaka, K.

AU - Sagara, K.

AU - Dozono, M.

AU - Fujita, Kunihiro

AU - Ihara, E.

AU - Kaneda, T.

AU - Kato, M.

AU - Kawabata, T.

AU - Kuroita, S.

AU - Maeda, Y.

AU - Matsubara, H.

AU - Okamura, H.

AU - Sakemi, Y.

AU - Sekiguchi, K.

AU - Shimizu, Y.

AU - Sugimoto, T.

AU - Tamii, A.

AU - Wakasa, Tomotsugu

PY - 2008/11/27

Y1 - 2008/11/27

N2 - In our previous measurement of pd radiative capture at Ed = 137 and 196MeV, we found an interesting fact that the measured tensor analyzing powers show the relation Axx ≈ Ayy, although calculated Axx and Ayy are apparently different, Axx ≠ Ayy. The measured Ayy agrees fairly well with the 3N calculations, and the measured Axx largely disagrees with calculated Axx. Similar experiments on pd capture have been made at KVI at nearly the same energies of 130-180MeV. The KVI data also support Axx ≈ Ayy relation, but absolute values of Axx and Ayy at KVI are about half of RCNP data. Therefore, we made a new experiment of pd capture at Ed =196MeV. Azz was measured in three different ways, and data analysis is in progress. Preliminary data seem to support our previous data.

AB - In our previous measurement of pd radiative capture at Ed = 137 and 196MeV, we found an interesting fact that the measured tensor analyzing powers show the relation Axx ≈ Ayy, although calculated Axx and Ayy are apparently different, Axx ≠ Ayy. The measured Ayy agrees fairly well with the 3N calculations, and the measured Axx largely disagrees with calculated Axx. Similar experiments on pd capture have been made at KVI at nearly the same energies of 130-180MeV. The KVI data also support Axx ≈ Ayy relation, but absolute values of Axx and Ayy at KVI are about half of RCNP data. Therefore, we made a new experiment of pd capture at Ed =196MeV. Azz was measured in three different ways, and data analysis is in progress. Preliminary data seem to support our previous data.

UR - http://www.scopus.com/inward/record.url?scp=57849118070&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=57849118070&partnerID=8YFLogxK

U2 - 10.1007/s00601-008-0285-8

DO - 10.1007/s00601-008-0285-8

M3 - Article

VL - 44

SP - 179

EP - 181

JO - Few-Body Systems

JF - Few-Body Systems

SN - 0177-7963

IS - 1-4

ER -