Measurement of Cardiac Contractility Using Fetal Isovolumetric Contraction Time in Fetal Tachyarrhythmia

Yasuyuki Fujita, Neil Athayde, Shoji Tokunaga, Brian Trudinger

Research output: Contribution to journalArticle

Abstract

The isovolumetric contraction time (ICT) is known to be an index of cardiac contractility. In this study, we examined the relationship between the fetal ICT and fetal heart rate (FHR) and evaluated the usefulness of ICT in the assessment of fetal cardiac contractility in cases with fetal tachyarrhythmia. Seven cases with fetal tachyarrhythmia between 32 and 40 weeks' gestation were included in this study. The fetal ICT was measured using a continuous Doppler device and digital filters. The relationship between the fetal ICT and FHR was analyzed using the Spearman's rank correlation test in each fetus. Based on the FHR and ultrasound findings of hydrops at the measurement of ICT, the obtained data were divided into three groups: normal, tachyarrhythmia only and hydrops. The clinical usefulness of ICT was assessed using the random effect model. In 7 fetuses, a total of 60 data points were obtained. A significant correlation between fetal ICT and FHR was not noted in each fetus. The ICT of the hydrops group was significantly prolonged compared with those of the normal and tachyarrhythmia-only groups (p < 0.01). An association between the fetal ICT and FHR is not noted and the fetal ICT might have some utility to detect impaired fetal cardiac contractility even in fetuses with tachyarrhythmia.

Original languageEnglish
Pages (from-to)184-188
Number of pages5
JournalUltrasound in Medicine and Biology
Volume37
Issue number2
DOIs
Publication statusPublished - Feb 1 2011

Fingerprint

Tachycardia
contraction
heart rate
Fetal Heart Rate
fetuses
Fetus
Edema
digital filters
filters
Equipment and Supplies
Pregnancy

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Radiological and Ultrasound Technology
  • Acoustics and Ultrasonics

Cite this

Measurement of Cardiac Contractility Using Fetal Isovolumetric Contraction Time in Fetal Tachyarrhythmia. / Fujita, Yasuyuki; Athayde, Neil; Tokunaga, Shoji; Trudinger, Brian.

In: Ultrasound in Medicine and Biology, Vol. 37, No. 2, 01.02.2011, p. 184-188.

Research output: Contribution to journalArticle

Fujita, Yasuyuki ; Athayde, Neil ; Tokunaga, Shoji ; Trudinger, Brian. / Measurement of Cardiac Contractility Using Fetal Isovolumetric Contraction Time in Fetal Tachyarrhythmia. In: Ultrasound in Medicine and Biology. 2011 ; Vol. 37, No. 2. pp. 184-188.
@article{bc2eeb8546a047529713a26ef7c1a2f7,
title = "Measurement of Cardiac Contractility Using Fetal Isovolumetric Contraction Time in Fetal Tachyarrhythmia",
abstract = "The isovolumetric contraction time (ICT) is known to be an index of cardiac contractility. In this study, we examined the relationship between the fetal ICT and fetal heart rate (FHR) and evaluated the usefulness of ICT in the assessment of fetal cardiac contractility in cases with fetal tachyarrhythmia. Seven cases with fetal tachyarrhythmia between 32 and 40 weeks' gestation were included in this study. The fetal ICT was measured using a continuous Doppler device and digital filters. The relationship between the fetal ICT and FHR was analyzed using the Spearman's rank correlation test in each fetus. Based on the FHR and ultrasound findings of hydrops at the measurement of ICT, the obtained data were divided into three groups: normal, tachyarrhythmia only and hydrops. The clinical usefulness of ICT was assessed using the random effect model. In 7 fetuses, a total of 60 data points were obtained. A significant correlation between fetal ICT and FHR was not noted in each fetus. The ICT of the hydrops group was significantly prolonged compared with those of the normal and tachyarrhythmia-only groups (p < 0.01). An association between the fetal ICT and FHR is not noted and the fetal ICT might have some utility to detect impaired fetal cardiac contractility even in fetuses with tachyarrhythmia.",
author = "Yasuyuki Fujita and Neil Athayde and Shoji Tokunaga and Brian Trudinger",
year = "2011",
month = "2",
day = "1",
doi = "10.1016/j.ultrasmedbio.2010.10.027",
language = "English",
volume = "37",
pages = "184--188",
journal = "Ultrasound in Medicine and Biology",
issn = "0301-5629",
publisher = "Elsevier USA",
number = "2",

}

TY - JOUR

T1 - Measurement of Cardiac Contractility Using Fetal Isovolumetric Contraction Time in Fetal Tachyarrhythmia

AU - Fujita, Yasuyuki

AU - Athayde, Neil

AU - Tokunaga, Shoji

AU - Trudinger, Brian

PY - 2011/2/1

Y1 - 2011/2/1

N2 - The isovolumetric contraction time (ICT) is known to be an index of cardiac contractility. In this study, we examined the relationship between the fetal ICT and fetal heart rate (FHR) and evaluated the usefulness of ICT in the assessment of fetal cardiac contractility in cases with fetal tachyarrhythmia. Seven cases with fetal tachyarrhythmia between 32 and 40 weeks' gestation were included in this study. The fetal ICT was measured using a continuous Doppler device and digital filters. The relationship between the fetal ICT and FHR was analyzed using the Spearman's rank correlation test in each fetus. Based on the FHR and ultrasound findings of hydrops at the measurement of ICT, the obtained data were divided into three groups: normal, tachyarrhythmia only and hydrops. The clinical usefulness of ICT was assessed using the random effect model. In 7 fetuses, a total of 60 data points were obtained. A significant correlation between fetal ICT and FHR was not noted in each fetus. The ICT of the hydrops group was significantly prolonged compared with those of the normal and tachyarrhythmia-only groups (p < 0.01). An association between the fetal ICT and FHR is not noted and the fetal ICT might have some utility to detect impaired fetal cardiac contractility even in fetuses with tachyarrhythmia.

AB - The isovolumetric contraction time (ICT) is known to be an index of cardiac contractility. In this study, we examined the relationship between the fetal ICT and fetal heart rate (FHR) and evaluated the usefulness of ICT in the assessment of fetal cardiac contractility in cases with fetal tachyarrhythmia. Seven cases with fetal tachyarrhythmia between 32 and 40 weeks' gestation were included in this study. The fetal ICT was measured using a continuous Doppler device and digital filters. The relationship between the fetal ICT and FHR was analyzed using the Spearman's rank correlation test in each fetus. Based on the FHR and ultrasound findings of hydrops at the measurement of ICT, the obtained data were divided into three groups: normal, tachyarrhythmia only and hydrops. The clinical usefulness of ICT was assessed using the random effect model. In 7 fetuses, a total of 60 data points were obtained. A significant correlation between fetal ICT and FHR was not noted in each fetus. The ICT of the hydrops group was significantly prolonged compared with those of the normal and tachyarrhythmia-only groups (p < 0.01). An association between the fetal ICT and FHR is not noted and the fetal ICT might have some utility to detect impaired fetal cardiac contractility even in fetuses with tachyarrhythmia.

UR - http://www.scopus.com/inward/record.url?scp=78751622633&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78751622633&partnerID=8YFLogxK

U2 - 10.1016/j.ultrasmedbio.2010.10.027

DO - 10.1016/j.ultrasmedbio.2010.10.027

M3 - Article

C2 - 21208736

AN - SCOPUS:78751622633

VL - 37

SP - 184

EP - 188

JO - Ultrasound in Medicine and Biology

JF - Ultrasound in Medicine and Biology

SN - 0301-5629

IS - 2

ER -