Measurement of excellent condition to RLC parameter for electrical sterilization on Escherichia coli

H. K. Lee, J. Suehiro, M. H. So, M. Hara, D. C. Lee

Research output: Contribution to conferencePaper

3 Citations (Scopus)

Abstract

We measured the survivability ratio of Escherichia coli suspension to apply the impulse generator. In this experiment, we desired to find the excellent condition of the applied impulse parameter in experiment. The experiment are performed by using the fixed R and C value and the changed L values in RLC discharging network and compared with the survivability in each cases. Ultimately, the experiment results show that the parameters to decide pulse waveform in discharging circuit are the critical factor on the condition of sterilization.

Original languageEnglish
Pages1136-1139
Number of pages4
Publication statusPublished - Jan 1 1997
Externally publishedYes
EventProceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2) - Seoul, Korea
Duration: May 25 1997May 30 1997

Other

OtherProceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2)
CitySeoul, Korea
Period5/25/975/30/97

Fingerprint

Escherichia
Escherichia coli
impulse generators
RLC circuits
impulses
waveforms
Experiments
pulses
Suspensions
Networks (circuits)

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Materials Chemistry

Cite this

Lee, H. K., Suehiro, J., So, M. H., Hara, M., & Lee, D. C. (1997). Measurement of excellent condition to RLC parameter for electrical sterilization on Escherichia coli. 1136-1139. Paper presented at Proceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2), Seoul, Korea, .

Measurement of excellent condition to RLC parameter for electrical sterilization on Escherichia coli. / Lee, H. K.; Suehiro, J.; So, M. H.; Hara, M.; Lee, D. C.

1997. 1136-1139 Paper presented at Proceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2), Seoul, Korea, .

Research output: Contribution to conferencePaper

Lee, HK, Suehiro, J, So, MH, Hara, M & Lee, DC 1997, 'Measurement of excellent condition to RLC parameter for electrical sterilization on Escherichia coli', Paper presented at Proceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2), Seoul, Korea, 5/25/97 - 5/30/97 pp. 1136-1139.
Lee HK, Suehiro J, So MH, Hara M, Lee DC. Measurement of excellent condition to RLC parameter for electrical sterilization on Escherichia coli. 1997. Paper presented at Proceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2), Seoul, Korea, .
Lee, H. K. ; Suehiro, J. ; So, M. H. ; Hara, M. ; Lee, D. C. / Measurement of excellent condition to RLC parameter for electrical sterilization on Escherichia coli. Paper presented at Proceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2), Seoul, Korea, .4 p.
@conference{6ab791a1cada4726b637f0944647aadb,
title = "Measurement of excellent condition to RLC parameter for electrical sterilization on Escherichia coli",
abstract = "We measured the survivability ratio of Escherichia coli suspension to apply the impulse generator. In this experiment, we desired to find the excellent condition of the applied impulse parameter in experiment. The experiment are performed by using the fixed R and C value and the changed L values in RLC discharging network and compared with the survivability in each cases. Ultimately, the experiment results show that the parameters to decide pulse waveform in discharging circuit are the critical factor on the condition of sterilization.",
author = "Lee, {H. K.} and J. Suehiro and So, {M. H.} and M. Hara and Lee, {D. C.}",
year = "1997",
month = "1",
day = "1",
language = "English",
pages = "1136--1139",
note = "Proceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2) ; Conference date: 25-05-1997 Through 30-05-1997",

}

TY - CONF

T1 - Measurement of excellent condition to RLC parameter for electrical sterilization on Escherichia coli

AU - Lee, H. K.

AU - Suehiro, J.

AU - So, M. H.

AU - Hara, M.

AU - Lee, D. C.

PY - 1997/1/1

Y1 - 1997/1/1

N2 - We measured the survivability ratio of Escherichia coli suspension to apply the impulse generator. In this experiment, we desired to find the excellent condition of the applied impulse parameter in experiment. The experiment are performed by using the fixed R and C value and the changed L values in RLC discharging network and compared with the survivability in each cases. Ultimately, the experiment results show that the parameters to decide pulse waveform in discharging circuit are the critical factor on the condition of sterilization.

AB - We measured the survivability ratio of Escherichia coli suspension to apply the impulse generator. In this experiment, we desired to find the excellent condition of the applied impulse parameter in experiment. The experiment are performed by using the fixed R and C value and the changed L values in RLC discharging network and compared with the survivability in each cases. Ultimately, the experiment results show that the parameters to decide pulse waveform in discharging circuit are the critical factor on the condition of sterilization.

UR - http://www.scopus.com/inward/record.url?scp=0030683049&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030683049&partnerID=8YFLogxK

M3 - Paper

AN - SCOPUS:0030683049

SP - 1136

EP - 1139

ER -