Measurement of HLW glass dissolution/alteration kinetics by using micro-reactor flow-through test method

Yaohiro Inagaki, S. Mitsui, H. Makigaki, Kazuya Idemitsu, Tatsumi Arima, T. Banba, K. Noshita

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

A new type of flow-through test method using micro-reactor was developed and applied to measurement of the dissolution/alteration kinetics for a Japanese type of simulated HLW glass, P0798. In this test method, a face of coupon shaped glass specimen (30mm x 10mm x 4mm size) is in contact with a micro-channel (20mm length, 2mm width, 0.16mm depth) constructed on a PTFE (Teflon®) plate, and a solution is injected into the inlet of micro-channel at a constant rate. The injected solution, which flows through the micro-channel reacting with the glass to the outlet, is retrieved at certain intervals to be analyzed for determination of the glass dissolution/alteration rate. After the test, the glass specimen removed from the micro-reactor is subjected to surface analyses. This test method has major features as follows, 1) any controlled solution condition can be provided over the test duration, 2) a relatively high S/V ratio can be provided by use of micro-reactor in spite of using coupon shaped glass specimen, which results in precise and consistent analyses of both the solution and the reacted glass surface, 3) the test apparatus is simple with compact size and easy operation, which allows a flexible setup of test conditions. By use of this test method the dissolution/alteration rate for P0798 glass was measured as a function of pH, temperature, and time, and the results indicated that this test method is applicable and suitable for evaluation of the dissolution/alteration kinetics.

Original languageEnglish
Title of host publicationScientific Basis for Nuclear Waste Management XXXIII
Pages219-228
Number of pages10
Publication statusPublished - Dec 1 2009
Event32nd Symposium on Scientific Basis for Nuclear Waste Management - St. Petersburg, Russian Federation
Duration: May 24 2009May 29 2009

Publication series

NameMaterials Research Society Symposium Proceedings
Volume1193
ISSN (Print)0272-9172

Other

Other32nd Symposium on Scientific Basis for Nuclear Waste Management
CountryRussian Federation
CitySt. Petersburg
Period5/24/095/29/09

Fingerprint

dissolving
Dissolution
reactors
Glass
Kinetics
glass
kinetics
Polytetrafluoroethylene
Polytetrafluoroethylenes
teflon (trademark)
outlets
intervals
evaluation

All Science Journal Classification (ASJC) codes

  • Materials Science(all)
  • Condensed Matter Physics
  • Mechanics of Materials
  • Mechanical Engineering

Cite this

Inagaki, Y., Mitsui, S., Makigaki, H., Idemitsu, K., Arima, T., Banba, T., & Noshita, K. (2009). Measurement of HLW glass dissolution/alteration kinetics by using micro-reactor flow-through test method. In Scientific Basis for Nuclear Waste Management XXXIII (pp. 219-228). (Materials Research Society Symposium Proceedings; Vol. 1193).

Measurement of HLW glass dissolution/alteration kinetics by using micro-reactor flow-through test method. / Inagaki, Yaohiro; Mitsui, S.; Makigaki, H.; Idemitsu, Kazuya; Arima, Tatsumi; Banba, T.; Noshita, K.

Scientific Basis for Nuclear Waste Management XXXIII. 2009. p. 219-228 (Materials Research Society Symposium Proceedings; Vol. 1193).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Inagaki, Y, Mitsui, S, Makigaki, H, Idemitsu, K, Arima, T, Banba, T & Noshita, K 2009, Measurement of HLW glass dissolution/alteration kinetics by using micro-reactor flow-through test method. in Scientific Basis for Nuclear Waste Management XXXIII. Materials Research Society Symposium Proceedings, vol. 1193, pp. 219-228, 32nd Symposium on Scientific Basis for Nuclear Waste Management, St. Petersburg, Russian Federation, 5/24/09.
Inagaki Y, Mitsui S, Makigaki H, Idemitsu K, Arima T, Banba T et al. Measurement of HLW glass dissolution/alteration kinetics by using micro-reactor flow-through test method. In Scientific Basis for Nuclear Waste Management XXXIII. 2009. p. 219-228. (Materials Research Society Symposium Proceedings).
Inagaki, Yaohiro ; Mitsui, S. ; Makigaki, H. ; Idemitsu, Kazuya ; Arima, Tatsumi ; Banba, T. ; Noshita, K. / Measurement of HLW glass dissolution/alteration kinetics by using micro-reactor flow-through test method. Scientific Basis for Nuclear Waste Management XXXIII. 2009. pp. 219-228 (Materials Research Society Symposium Proceedings).
@inproceedings{69816081fec2471a8c85a38c49490c3d,
title = "Measurement of HLW glass dissolution/alteration kinetics by using micro-reactor flow-through test method",
abstract = "A new type of flow-through test method using micro-reactor was developed and applied to measurement of the dissolution/alteration kinetics for a Japanese type of simulated HLW glass, P0798. In this test method, a face of coupon shaped glass specimen (30mm x 10mm x 4mm size) is in contact with a micro-channel (20mm length, 2mm width, 0.16mm depth) constructed on a PTFE (Teflon{\circledR}) plate, and a solution is injected into the inlet of micro-channel at a constant rate. The injected solution, which flows through the micro-channel reacting with the glass to the outlet, is retrieved at certain intervals to be analyzed for determination of the glass dissolution/alteration rate. After the test, the glass specimen removed from the micro-reactor is subjected to surface analyses. This test method has major features as follows, 1) any controlled solution condition can be provided over the test duration, 2) a relatively high S/V ratio can be provided by use of micro-reactor in spite of using coupon shaped glass specimen, which results in precise and consistent analyses of both the solution and the reacted glass surface, 3) the test apparatus is simple with compact size and easy operation, which allows a flexible setup of test conditions. By use of this test method the dissolution/alteration rate for P0798 glass was measured as a function of pH, temperature, and time, and the results indicated that this test method is applicable and suitable for evaluation of the dissolution/alteration kinetics.",
author = "Yaohiro Inagaki and S. Mitsui and H. Makigaki and Kazuya Idemitsu and Tatsumi Arima and T. Banba and K. Noshita",
year = "2009",
month = "12",
day = "1",
language = "English",
isbn = "9781605111667",
series = "Materials Research Society Symposium Proceedings",
pages = "219--228",
booktitle = "Scientific Basis for Nuclear Waste Management XXXIII",

}

TY - GEN

T1 - Measurement of HLW glass dissolution/alteration kinetics by using micro-reactor flow-through test method

AU - Inagaki, Yaohiro

AU - Mitsui, S.

AU - Makigaki, H.

AU - Idemitsu, Kazuya

AU - Arima, Tatsumi

AU - Banba, T.

AU - Noshita, K.

PY - 2009/12/1

Y1 - 2009/12/1

N2 - A new type of flow-through test method using micro-reactor was developed and applied to measurement of the dissolution/alteration kinetics for a Japanese type of simulated HLW glass, P0798. In this test method, a face of coupon shaped glass specimen (30mm x 10mm x 4mm size) is in contact with a micro-channel (20mm length, 2mm width, 0.16mm depth) constructed on a PTFE (Teflon®) plate, and a solution is injected into the inlet of micro-channel at a constant rate. The injected solution, which flows through the micro-channel reacting with the glass to the outlet, is retrieved at certain intervals to be analyzed for determination of the glass dissolution/alteration rate. After the test, the glass specimen removed from the micro-reactor is subjected to surface analyses. This test method has major features as follows, 1) any controlled solution condition can be provided over the test duration, 2) a relatively high S/V ratio can be provided by use of micro-reactor in spite of using coupon shaped glass specimen, which results in precise and consistent analyses of both the solution and the reacted glass surface, 3) the test apparatus is simple with compact size and easy operation, which allows a flexible setup of test conditions. By use of this test method the dissolution/alteration rate for P0798 glass was measured as a function of pH, temperature, and time, and the results indicated that this test method is applicable and suitable for evaluation of the dissolution/alteration kinetics.

AB - A new type of flow-through test method using micro-reactor was developed and applied to measurement of the dissolution/alteration kinetics for a Japanese type of simulated HLW glass, P0798. In this test method, a face of coupon shaped glass specimen (30mm x 10mm x 4mm size) is in contact with a micro-channel (20mm length, 2mm width, 0.16mm depth) constructed on a PTFE (Teflon®) plate, and a solution is injected into the inlet of micro-channel at a constant rate. The injected solution, which flows through the micro-channel reacting with the glass to the outlet, is retrieved at certain intervals to be analyzed for determination of the glass dissolution/alteration rate. After the test, the glass specimen removed from the micro-reactor is subjected to surface analyses. This test method has major features as follows, 1) any controlled solution condition can be provided over the test duration, 2) a relatively high S/V ratio can be provided by use of micro-reactor in spite of using coupon shaped glass specimen, which results in precise and consistent analyses of both the solution and the reacted glass surface, 3) the test apparatus is simple with compact size and easy operation, which allows a flexible setup of test conditions. By use of this test method the dissolution/alteration rate for P0798 glass was measured as a function of pH, temperature, and time, and the results indicated that this test method is applicable and suitable for evaluation of the dissolution/alteration kinetics.

UR - http://www.scopus.com/inward/record.url?scp=77951679114&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951679114&partnerID=8YFLogxK

M3 - Conference contribution

SN - 9781605111667

T3 - Materials Research Society Symposium Proceedings

SP - 219

EP - 228

BT - Scientific Basis for Nuclear Waste Management XXXIII

ER -