Measurement of surface melting temperature with high-speed pyrometers by containerless method

Tatsumi Arima, Yoshiharu Kawauchi, Taku Matsumoto, Yaohiro Inagaki, Kazuya Idemitsu, Isamu Sato, Takashi Hirosawa

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The apparatus for measurement of melting points of actinide oxides is being developed as the containerless method. It consists mainly of Nd:YAG laser, high-speed pyrometers and stainless cell with glass window. In this method, the melting point is defined as the thermal arrest observed during solidification of a part of sample. Although the accuracy of melting point was relatively low so far, the verification of measurement system was made for Ni, Mo and CeO 2-Nb2O5 samples.

Original languageEnglish
Title of host publication2012 Proceedings of SICE Annual Conference, SICE 2012
PublisherSociety of Instrument and Control Engineers (SICE)
Pages32-34
Number of pages3
ISBN (Print)9781467322591
Publication statusPublished - Jan 1 2012
Event2012 51st Annual Conference on of the Society of Instrument and Control Engineers of Japan, SICE 2012 - Akita, Japan
Duration: Aug 20 2012Aug 23 2012

Publication series

NameProceedings of the SICE Annual Conference

Other

Other2012 51st Annual Conference on of the Society of Instrument and Control Engineers of Japan, SICE 2012
CountryJapan
CityAkita
Period8/20/128/23/12

Fingerprint

Pyrometers
Melting point
Actinides
Solidification
Glass
Oxides
Lasers

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Computer Science Applications
  • Electrical and Electronic Engineering

Cite this

Arima, T., Kawauchi, Y., Matsumoto, T., Inagaki, Y., Idemitsu, K., Sato, I., & Hirosawa, T. (2012). Measurement of surface melting temperature with high-speed pyrometers by containerless method. In 2012 Proceedings of SICE Annual Conference, SICE 2012 (pp. 32-34). [6318401] (Proceedings of the SICE Annual Conference). Society of Instrument and Control Engineers (SICE).

Measurement of surface melting temperature with high-speed pyrometers by containerless method. / Arima, Tatsumi; Kawauchi, Yoshiharu; Matsumoto, Taku; Inagaki, Yaohiro; Idemitsu, Kazuya; Sato, Isamu; Hirosawa, Takashi.

2012 Proceedings of SICE Annual Conference, SICE 2012. Society of Instrument and Control Engineers (SICE), 2012. p. 32-34 6318401 (Proceedings of the SICE Annual Conference).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Arima, T, Kawauchi, Y, Matsumoto, T, Inagaki, Y, Idemitsu, K, Sato, I & Hirosawa, T 2012, Measurement of surface melting temperature with high-speed pyrometers by containerless method. in 2012 Proceedings of SICE Annual Conference, SICE 2012., 6318401, Proceedings of the SICE Annual Conference, Society of Instrument and Control Engineers (SICE), pp. 32-34, 2012 51st Annual Conference on of the Society of Instrument and Control Engineers of Japan, SICE 2012, Akita, Japan, 8/20/12.
Arima T, Kawauchi Y, Matsumoto T, Inagaki Y, Idemitsu K, Sato I et al. Measurement of surface melting temperature with high-speed pyrometers by containerless method. In 2012 Proceedings of SICE Annual Conference, SICE 2012. Society of Instrument and Control Engineers (SICE). 2012. p. 32-34. 6318401. (Proceedings of the SICE Annual Conference).
Arima, Tatsumi ; Kawauchi, Yoshiharu ; Matsumoto, Taku ; Inagaki, Yaohiro ; Idemitsu, Kazuya ; Sato, Isamu ; Hirosawa, Takashi. / Measurement of surface melting temperature with high-speed pyrometers by containerless method. 2012 Proceedings of SICE Annual Conference, SICE 2012. Society of Instrument and Control Engineers (SICE), 2012. pp. 32-34 (Proceedings of the SICE Annual Conference).
@inproceedings{9a306641d99f479bb59be36182f4d185,
title = "Measurement of surface melting temperature with high-speed pyrometers by containerless method",
abstract = "The apparatus for measurement of melting points of actinide oxides is being developed as the containerless method. It consists mainly of Nd:YAG laser, high-speed pyrometers and stainless cell with glass window. In this method, the melting point is defined as the thermal arrest observed during solidification of a part of sample. Although the accuracy of melting point was relatively low so far, the verification of measurement system was made for Ni, Mo and CeO 2-Nb2O5 samples.",
author = "Tatsumi Arima and Yoshiharu Kawauchi and Taku Matsumoto and Yaohiro Inagaki and Kazuya Idemitsu and Isamu Sato and Takashi Hirosawa",
year = "2012",
month = "1",
day = "1",
language = "English",
isbn = "9781467322591",
series = "Proceedings of the SICE Annual Conference",
publisher = "Society of Instrument and Control Engineers (SICE)",
pages = "32--34",
booktitle = "2012 Proceedings of SICE Annual Conference, SICE 2012",

}

TY - GEN

T1 - Measurement of surface melting temperature with high-speed pyrometers by containerless method

AU - Arima, Tatsumi

AU - Kawauchi, Yoshiharu

AU - Matsumoto, Taku

AU - Inagaki, Yaohiro

AU - Idemitsu, Kazuya

AU - Sato, Isamu

AU - Hirosawa, Takashi

PY - 2012/1/1

Y1 - 2012/1/1

N2 - The apparatus for measurement of melting points of actinide oxides is being developed as the containerless method. It consists mainly of Nd:YAG laser, high-speed pyrometers and stainless cell with glass window. In this method, the melting point is defined as the thermal arrest observed during solidification of a part of sample. Although the accuracy of melting point was relatively low so far, the verification of measurement system was made for Ni, Mo and CeO 2-Nb2O5 samples.

AB - The apparatus for measurement of melting points of actinide oxides is being developed as the containerless method. It consists mainly of Nd:YAG laser, high-speed pyrometers and stainless cell with glass window. In this method, the melting point is defined as the thermal arrest observed during solidification of a part of sample. Although the accuracy of melting point was relatively low so far, the verification of measurement system was made for Ni, Mo and CeO 2-Nb2O5 samples.

UR - http://www.scopus.com/inward/record.url?scp=84869402017&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84869402017&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84869402017

SN - 9781467322591

T3 - Proceedings of the SICE Annual Conference

SP - 32

EP - 34

BT - 2012 Proceedings of SICE Annual Conference, SICE 2012

PB - Society of Instrument and Control Engineers (SICE)

ER -