MEASUREMENT OF TRAPPED MAGNETIC-FLUX DISTRIBUTION IN A SUPERCONDUCTING THIN FILM WITH AN ARRAY OF JOSEPHSON TUNNEL JUNCTIONS.

K. Yoshida, N. Uchida, K. Enpuku, F. Irie

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A spatial distribution of the magnetic flux trapped in superconducting thin films is measured using an array of Josephson tunnel junctions as magnetic sensor. The present method, which uses an increase of quasiparticle tunneling currents due to magnetic flux trapped in junction electrodes, gives magnetic-flux resolution of the order of a single flux quantum.

Original languageEnglish
Title of host publicationUnknown Host Publication Title
PublisherNorth-Holland
Pages911-912
Number of pages2
Editionpt 2
ISBN (Print)0444869107
Publication statusPublished - Dec 1 1984

Publication series

Name
Numberpt 2

Fingerprint

Superconducting films
Tunnel junctions
Magnetic flux
Magnetic sensors
Spatial distribution
Fluxes
Electrodes

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Yoshida, K., Uchida, N., Enpuku, K., & Irie, F. (1984). MEASUREMENT OF TRAPPED MAGNETIC-FLUX DISTRIBUTION IN A SUPERCONDUCTING THIN FILM WITH AN ARRAY OF JOSEPHSON TUNNEL JUNCTIONS. In Unknown Host Publication Title (pt 2 ed., pp. 911-912). North-Holland.

MEASUREMENT OF TRAPPED MAGNETIC-FLUX DISTRIBUTION IN A SUPERCONDUCTING THIN FILM WITH AN ARRAY OF JOSEPHSON TUNNEL JUNCTIONS. / Yoshida, K.; Uchida, N.; Enpuku, K.; Irie, F.

Unknown Host Publication Title. pt 2. ed. North-Holland, 1984. p. 911-912.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Yoshida, K, Uchida, N, Enpuku, K & Irie, F 1984, MEASUREMENT OF TRAPPED MAGNETIC-FLUX DISTRIBUTION IN A SUPERCONDUCTING THIN FILM WITH AN ARRAY OF JOSEPHSON TUNNEL JUNCTIONS. in Unknown Host Publication Title. pt 2 edn, North-Holland, pp. 911-912.
Yoshida K, Uchida N, Enpuku K, Irie F. MEASUREMENT OF TRAPPED MAGNETIC-FLUX DISTRIBUTION IN A SUPERCONDUCTING THIN FILM WITH AN ARRAY OF JOSEPHSON TUNNEL JUNCTIONS. In Unknown Host Publication Title. pt 2 ed. North-Holland. 1984. p. 911-912
Yoshida, K. ; Uchida, N. ; Enpuku, K. ; Irie, F. / MEASUREMENT OF TRAPPED MAGNETIC-FLUX DISTRIBUTION IN A SUPERCONDUCTING THIN FILM WITH AN ARRAY OF JOSEPHSON TUNNEL JUNCTIONS. Unknown Host Publication Title. pt 2. ed. North-Holland, 1984. pp. 911-912
@inproceedings{fb6bd781641240c78dcbfc0748ed5614,
title = "MEASUREMENT OF TRAPPED MAGNETIC-FLUX DISTRIBUTION IN A SUPERCONDUCTING THIN FILM WITH AN ARRAY OF JOSEPHSON TUNNEL JUNCTIONS.",
abstract = "A spatial distribution of the magnetic flux trapped in superconducting thin films is measured using an array of Josephson tunnel junctions as magnetic sensor. The present method, which uses an increase of quasiparticle tunneling currents due to magnetic flux trapped in junction electrodes, gives magnetic-flux resolution of the order of a single flux quantum.",
author = "K. Yoshida and N. Uchida and K. Enpuku and F. Irie",
year = "1984",
month = "12",
day = "1",
language = "English",
isbn = "0444869107",
publisher = "North-Holland",
number = "pt 2",
pages = "911--912",
booktitle = "Unknown Host Publication Title",
edition = "pt 2",

}

TY - GEN

T1 - MEASUREMENT OF TRAPPED MAGNETIC-FLUX DISTRIBUTION IN A SUPERCONDUCTING THIN FILM WITH AN ARRAY OF JOSEPHSON TUNNEL JUNCTIONS.

AU - Yoshida, K.

AU - Uchida, N.

AU - Enpuku, K.

AU - Irie, F.

PY - 1984/12/1

Y1 - 1984/12/1

N2 - A spatial distribution of the magnetic flux trapped in superconducting thin films is measured using an array of Josephson tunnel junctions as magnetic sensor. The present method, which uses an increase of quasiparticle tunneling currents due to magnetic flux trapped in junction electrodes, gives magnetic-flux resolution of the order of a single flux quantum.

AB - A spatial distribution of the magnetic flux trapped in superconducting thin films is measured using an array of Josephson tunnel junctions as magnetic sensor. The present method, which uses an increase of quasiparticle tunneling currents due to magnetic flux trapped in junction electrodes, gives magnetic-flux resolution of the order of a single flux quantum.

UR - http://www.scopus.com/inward/record.url?scp=0021725274&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021725274&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0021725274

SN - 0444869107

SP - 911

EP - 912

BT - Unknown Host Publication Title

PB - North-Holland

ER -