Measurement of Visual Evoked Magnetic Fields Associated with Pattern Recognition

Shiann Fong Huang, Keiji Iramina, Masato Yumoto, Shoogo Ueno

Research output: Contribution to journalArticle

Abstract

The endogenous negativity of the early negative component of event-related potential or event-related magnetic field might reveal some aspects of cognitive processes or stimulus identification. The authors identified the activated area for an early negative component (NA), which seems to be associated with pattern recognition processes, by measuring the magnetic fields. The difference between the 50%/50% discriminative response and the 80%/20% discriminative response was also obtained. The visual evoked magnetic field was measured with a 204-channel whole-scalp superconducting quantum interference device gradiometer and estimated the equivalent current dipoles (ECD) to clarify the source localization of NA. Localization of a single ECD was applied for the main peak of the NA component in the magnetoencephalogram response. The ECD sources were localized in the frontal and temporal sections of the brain.

Original languageEnglish
Pages (from-to)3331-3333
Number of pages3
JournalIEEE Transactions on Magnetics
Volume39
Issue number5 II
DOIs
Publication statusPublished - Sep 1 2003
Externally publishedYes

Fingerprint

Pattern recognition
Magnetic fields
SQUIDs
Brain

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Cite this

Measurement of Visual Evoked Magnetic Fields Associated with Pattern Recognition. / Huang, Shiann Fong; Iramina, Keiji; Yumoto, Masato; Ueno, Shoogo.

In: IEEE Transactions on Magnetics, Vol. 39, No. 5 II, 01.09.2003, p. 3331-3333.

Research output: Contribution to journalArticle

Huang, Shiann Fong ; Iramina, Keiji ; Yumoto, Masato ; Ueno, Shoogo. / Measurement of Visual Evoked Magnetic Fields Associated with Pattern Recognition. In: IEEE Transactions on Magnetics. 2003 ; Vol. 39, No. 5 II. pp. 3331-3333.
@article{dcfae3017b67440c934785a0d7b48351,
title = "Measurement of Visual Evoked Magnetic Fields Associated with Pattern Recognition",
abstract = "The endogenous negativity of the early negative component of event-related potential or event-related magnetic field might reveal some aspects of cognitive processes or stimulus identification. The authors identified the activated area for an early negative component (NA), which seems to be associated with pattern recognition processes, by measuring the magnetic fields. The difference between the 50{\%}/50{\%} discriminative response and the 80{\%}/20{\%} discriminative response was also obtained. The visual evoked magnetic field was measured with a 204-channel whole-scalp superconducting quantum interference device gradiometer and estimated the equivalent current dipoles (ECD) to clarify the source localization of NA. Localization of a single ECD was applied for the main peak of the NA component in the magnetoencephalogram response. The ECD sources were localized in the frontal and temporal sections of the brain.",
author = "Huang, {Shiann Fong} and Keiji Iramina and Masato Yumoto and Shoogo Ueno",
year = "2003",
month = "9",
day = "1",
doi = "10.1109/TMAG.2003.816767",
language = "English",
volume = "39",
pages = "3331--3333",
journal = "IEEE Transactions on Magnetics",
issn = "0018-9464",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "5 II",

}

TY - JOUR

T1 - Measurement of Visual Evoked Magnetic Fields Associated with Pattern Recognition

AU - Huang, Shiann Fong

AU - Iramina, Keiji

AU - Yumoto, Masato

AU - Ueno, Shoogo

PY - 2003/9/1

Y1 - 2003/9/1

N2 - The endogenous negativity of the early negative component of event-related potential or event-related magnetic field might reveal some aspects of cognitive processes or stimulus identification. The authors identified the activated area for an early negative component (NA), which seems to be associated with pattern recognition processes, by measuring the magnetic fields. The difference between the 50%/50% discriminative response and the 80%/20% discriminative response was also obtained. The visual evoked magnetic field was measured with a 204-channel whole-scalp superconducting quantum interference device gradiometer and estimated the equivalent current dipoles (ECD) to clarify the source localization of NA. Localization of a single ECD was applied for the main peak of the NA component in the magnetoencephalogram response. The ECD sources were localized in the frontal and temporal sections of the brain.

AB - The endogenous negativity of the early negative component of event-related potential or event-related magnetic field might reveal some aspects of cognitive processes or stimulus identification. The authors identified the activated area for an early negative component (NA), which seems to be associated with pattern recognition processes, by measuring the magnetic fields. The difference between the 50%/50% discriminative response and the 80%/20% discriminative response was also obtained. The visual evoked magnetic field was measured with a 204-channel whole-scalp superconducting quantum interference device gradiometer and estimated the equivalent current dipoles (ECD) to clarify the source localization of NA. Localization of a single ECD was applied for the main peak of the NA component in the magnetoencephalogram response. The ECD sources were localized in the frontal and temporal sections of the brain.

UR - http://www.scopus.com/inward/record.url?scp=0141883994&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0141883994&partnerID=8YFLogxK

U2 - 10.1109/TMAG.2003.816767

DO - 10.1109/TMAG.2003.816767

M3 - Article

AN - SCOPUS:0141883994

VL - 39

SP - 3331

EP - 3333

JO - IEEE Transactions on Magnetics

JF - IEEE Transactions on Magnetics

SN - 0018-9464

IS - 5 II

ER -