Measurements of the vapor-liquid coexistence curve and the critical locus for several refrigerant mixtures

Yukihiro Higashi, M. Uematsu, K. Watanabe

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Measurements of the vapor-liquid coexistence curve in the critical region for the systems of binary refrigerant mixture, i.e., Refrigerant 22 + Refrigerant 114 and Refrigerant 13B1 + Refrigerant 114, have been made by visual observation of the meniscus at the vapor-liquid interface within an optical cell. The experimental uncertainty of the temperature, density, and mass fraction is estimated within 15 mK, 0.5%, and 0.05%, respectively. The critical locus for these mixtures has been determined taking into consideration the disappearing meniscus level and the intensity of the critical opalescence. In accordance with the previous results of the Refrigerant 12 + Refrigerant 22 system, the coexistence curve for binary refrigerant mixtures is discussed. The composition dependence of the critical parameters for refrigerant mixtures is also discussed and compared with that of several predictive methods.

Original languageEnglish
Pages (from-to)29-40
Number of pages12
JournalInternational Journal of Thermophysics
Volume7
Issue number1
DOIs
Publication statusPublished - Jan 1 1986
Externally publishedYes

Fingerprint

refrigerants
loci
vapors
curves
liquids
menisci
opalescence
visual observation
liquid-vapor interfaces

All Science Journal Classification (ASJC) codes

  • Condensed Matter Physics

Cite this

Measurements of the vapor-liquid coexistence curve and the critical locus for several refrigerant mixtures. / Higashi, Yukihiro; Uematsu, M.; Watanabe, K.

In: International Journal of Thermophysics, Vol. 7, No. 1, 01.01.1986, p. 29-40.

Research output: Contribution to journalArticle

@article{ef5a3b3fd03f4aa187c2a266e38317f6,
title = "Measurements of the vapor-liquid coexistence curve and the critical locus for several refrigerant mixtures",
abstract = "Measurements of the vapor-liquid coexistence curve in the critical region for the systems of binary refrigerant mixture, i.e., Refrigerant 22 + Refrigerant 114 and Refrigerant 13B1 + Refrigerant 114, have been made by visual observation of the meniscus at the vapor-liquid interface within an optical cell. The experimental uncertainty of the temperature, density, and mass fraction is estimated within 15 mK, 0.5{\%}, and 0.05{\%}, respectively. The critical locus for these mixtures has been determined taking into consideration the disappearing meniscus level and the intensity of the critical opalescence. In accordance with the previous results of the Refrigerant 12 + Refrigerant 22 system, the coexistence curve for binary refrigerant mixtures is discussed. The composition dependence of the critical parameters for refrigerant mixtures is also discussed and compared with that of several predictive methods.",
author = "Yukihiro Higashi and M. Uematsu and K. Watanabe",
year = "1986",
month = "1",
day = "1",
doi = "10.1007/BF00503796",
language = "English",
volume = "7",
pages = "29--40",
journal = "International Journal of Thermophysics",
issn = "0195-928X",
publisher = "Springer New York",
number = "1",

}

TY - JOUR

T1 - Measurements of the vapor-liquid coexistence curve and the critical locus for several refrigerant mixtures

AU - Higashi, Yukihiro

AU - Uematsu, M.

AU - Watanabe, K.

PY - 1986/1/1

Y1 - 1986/1/1

N2 - Measurements of the vapor-liquid coexistence curve in the critical region for the systems of binary refrigerant mixture, i.e., Refrigerant 22 + Refrigerant 114 and Refrigerant 13B1 + Refrigerant 114, have been made by visual observation of the meniscus at the vapor-liquid interface within an optical cell. The experimental uncertainty of the temperature, density, and mass fraction is estimated within 15 mK, 0.5%, and 0.05%, respectively. The critical locus for these mixtures has been determined taking into consideration the disappearing meniscus level and the intensity of the critical opalescence. In accordance with the previous results of the Refrigerant 12 + Refrigerant 22 system, the coexistence curve for binary refrigerant mixtures is discussed. The composition dependence of the critical parameters for refrigerant mixtures is also discussed and compared with that of several predictive methods.

AB - Measurements of the vapor-liquid coexistence curve in the critical region for the systems of binary refrigerant mixture, i.e., Refrigerant 22 + Refrigerant 114 and Refrigerant 13B1 + Refrigerant 114, have been made by visual observation of the meniscus at the vapor-liquid interface within an optical cell. The experimental uncertainty of the temperature, density, and mass fraction is estimated within 15 mK, 0.5%, and 0.05%, respectively. The critical locus for these mixtures has been determined taking into consideration the disappearing meniscus level and the intensity of the critical opalescence. In accordance with the previous results of the Refrigerant 12 + Refrigerant 22 system, the coexistence curve for binary refrigerant mixtures is discussed. The composition dependence of the critical parameters for refrigerant mixtures is also discussed and compared with that of several predictive methods.

UR - http://www.scopus.com/inward/record.url?scp=0021896628&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021896628&partnerID=8YFLogxK

U2 - 10.1007/BF00503796

DO - 10.1007/BF00503796

M3 - Article

AN - SCOPUS:0021896628

VL - 7

SP - 29

EP - 40

JO - International Journal of Thermophysics

JF - International Journal of Thermophysics

SN - 0195-928X

IS - 1

ER -