Medical radiograph of nano-magnetic fluid used by spring-8 synchrotron radiation X-ray

Ken Ichi Makino, Masahiro Nakano, Hiroyuki Matsuura, Kazuharu Koide, Nobuo Noda, Dong Ying Ju, Pei Bian, Takashi Kumazawa, Mitsuo Akutsu, Kazunori Masuyama, Yusuke Uozumi, Nobuhito Tonohata, Shinzo Kimura, Takeshi Kondoh

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Nano Drug Delivery System (nano-DDS) is a new medical technology. We studied medical use used by about 7 [nm] ferromagnetic fluids. We searched good energy condition offerrofluid contrast medium radiograph image used by SPring-8 synchrotron radiation X-ray. As results, in case of low photon energy 15.0 [KeV] (λ = 0.8 Å). We showedferrofluid in Acryl amid gel and taro leaf and mugwort. #1. We found Low photon energy could show vascular tissue and ferrofluid distribution respectively. In case of medium photon energy 20.0 [KeV] (λ = 0.6 Å). We observed ferrofluid in rat ear lobe and rat stomach and rat foot. #2. We found medium photon energy could see several organizations by changing exposure. In case of high photon energy 25.0 [KeV] (λ = 0.5 Å). We showed ferrofluid in chicken egg and pork. #3. We found high proton energy was suitable for observing ferrofluid distribution in plain organization, but was not suitable for observing ferrofluid distribution in complicate organization.

Original languageEnglish
Title of host publication3rd International Conference on Innovative Computing Information and Control, ICICIC'08
DOIs
Publication statusPublished - Oct 2 2008
Event3rd International Conference on Innovative Computing Information and Control, ICICIC'08 - Dalian, Liaoning, China
Duration: Jun 18 2008Jun 20 2008

Publication series

Name3rd International Conference on Innovative Computing Information and Control, ICICIC'08

Other

Other3rd International Conference on Innovative Computing Information and Control, ICICIC'08
CountryChina
CityDalian, Liaoning
Period6/18/086/20/08

Fingerprint

Magnetic fluids
Synchrotron radiation
Photons
X rays
Rats
Contrast media
Protons
Gels
Tissue
Fluids

All Science Journal Classification (ASJC) codes

  • Computer Science Applications
  • Software
  • Control and Systems Engineering

Cite this

Makino, K. I., Nakano, M., Matsuura, H., Koide, K., Noda, N., Ju, D. Y., ... Kondoh, T. (2008). Medical radiograph of nano-magnetic fluid used by spring-8 synchrotron radiation X-ray. In 3rd International Conference on Innovative Computing Information and Control, ICICIC'08 [4603526] (3rd International Conference on Innovative Computing Information and Control, ICICIC'08). https://doi.org/10.1109/ICICIC.2008.353

Medical radiograph of nano-magnetic fluid used by spring-8 synchrotron radiation X-ray. / Makino, Ken Ichi; Nakano, Masahiro; Matsuura, Hiroyuki; Koide, Kazuharu; Noda, Nobuo; Ju, Dong Ying; Bian, Pei; Kumazawa, Takashi; Akutsu, Mitsuo; Masuyama, Kazunori; Uozumi, Yusuke; Tonohata, Nobuhito; Kimura, Shinzo; Kondoh, Takeshi.

3rd International Conference on Innovative Computing Information and Control, ICICIC'08. 2008. 4603526 (3rd International Conference on Innovative Computing Information and Control, ICICIC'08).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Makino, KI, Nakano, M, Matsuura, H, Koide, K, Noda, N, Ju, DY, Bian, P, Kumazawa, T, Akutsu, M, Masuyama, K, Uozumi, Y, Tonohata, N, Kimura, S & Kondoh, T 2008, Medical radiograph of nano-magnetic fluid used by spring-8 synchrotron radiation X-ray. in 3rd International Conference on Innovative Computing Information and Control, ICICIC'08., 4603526, 3rd International Conference on Innovative Computing Information and Control, ICICIC'08, 3rd International Conference on Innovative Computing Information and Control, ICICIC'08, Dalian, Liaoning, China, 6/18/08. https://doi.org/10.1109/ICICIC.2008.353
Makino KI, Nakano M, Matsuura H, Koide K, Noda N, Ju DY et al. Medical radiograph of nano-magnetic fluid used by spring-8 synchrotron radiation X-ray. In 3rd International Conference on Innovative Computing Information and Control, ICICIC'08. 2008. 4603526. (3rd International Conference on Innovative Computing Information and Control, ICICIC'08). https://doi.org/10.1109/ICICIC.2008.353
Makino, Ken Ichi ; Nakano, Masahiro ; Matsuura, Hiroyuki ; Koide, Kazuharu ; Noda, Nobuo ; Ju, Dong Ying ; Bian, Pei ; Kumazawa, Takashi ; Akutsu, Mitsuo ; Masuyama, Kazunori ; Uozumi, Yusuke ; Tonohata, Nobuhito ; Kimura, Shinzo ; Kondoh, Takeshi. / Medical radiograph of nano-magnetic fluid used by spring-8 synchrotron radiation X-ray. 3rd International Conference on Innovative Computing Information and Control, ICICIC'08. 2008. (3rd International Conference on Innovative Computing Information and Control, ICICIC'08).
@inproceedings{6e5c696f45984fbda62ac3e210407dd2,
title = "Medical radiograph of nano-magnetic fluid used by spring-8 synchrotron radiation X-ray",
abstract = "Nano Drug Delivery System (nano-DDS) is a new medical technology. We studied medical use used by about 7 [nm] ferromagnetic fluids. We searched good energy condition offerrofluid contrast medium radiograph image used by SPring-8 synchrotron radiation X-ray. As results, in case of low photon energy 15.0 [KeV] (λ = 0.8 {\AA}). We showedferrofluid in Acryl amid gel and taro leaf and mugwort. #1. We found Low photon energy could show vascular tissue and ferrofluid distribution respectively. In case of medium photon energy 20.0 [KeV] (λ = 0.6 {\AA}). We observed ferrofluid in rat ear lobe and rat stomach and rat foot. #2. We found medium photon energy could see several organizations by changing exposure. In case of high photon energy 25.0 [KeV] (λ = 0.5 {\AA}). We showed ferrofluid in chicken egg and pork. #3. We found high proton energy was suitable for observing ferrofluid distribution in plain organization, but was not suitable for observing ferrofluid distribution in complicate organization.",
author = "Makino, {Ken Ichi} and Masahiro Nakano and Hiroyuki Matsuura and Kazuharu Koide and Nobuo Noda and Ju, {Dong Ying} and Pei Bian and Takashi Kumazawa and Mitsuo Akutsu and Kazunori Masuyama and Yusuke Uozumi and Nobuhito Tonohata and Shinzo Kimura and Takeshi Kondoh",
year = "2008",
month = "10",
day = "2",
doi = "10.1109/ICICIC.2008.353",
language = "English",
isbn = "9780769531618",
series = "3rd International Conference on Innovative Computing Information and Control, ICICIC'08",
booktitle = "3rd International Conference on Innovative Computing Information and Control, ICICIC'08",

}

TY - GEN

T1 - Medical radiograph of nano-magnetic fluid used by spring-8 synchrotron radiation X-ray

AU - Makino, Ken Ichi

AU - Nakano, Masahiro

AU - Matsuura, Hiroyuki

AU - Koide, Kazuharu

AU - Noda, Nobuo

AU - Ju, Dong Ying

AU - Bian, Pei

AU - Kumazawa, Takashi

AU - Akutsu, Mitsuo

AU - Masuyama, Kazunori

AU - Uozumi, Yusuke

AU - Tonohata, Nobuhito

AU - Kimura, Shinzo

AU - Kondoh, Takeshi

PY - 2008/10/2

Y1 - 2008/10/2

N2 - Nano Drug Delivery System (nano-DDS) is a new medical technology. We studied medical use used by about 7 [nm] ferromagnetic fluids. We searched good energy condition offerrofluid contrast medium radiograph image used by SPring-8 synchrotron radiation X-ray. As results, in case of low photon energy 15.0 [KeV] (λ = 0.8 Å). We showedferrofluid in Acryl amid gel and taro leaf and mugwort. #1. We found Low photon energy could show vascular tissue and ferrofluid distribution respectively. In case of medium photon energy 20.0 [KeV] (λ = 0.6 Å). We observed ferrofluid in rat ear lobe and rat stomach and rat foot. #2. We found medium photon energy could see several organizations by changing exposure. In case of high photon energy 25.0 [KeV] (λ = 0.5 Å). We showed ferrofluid in chicken egg and pork. #3. We found high proton energy was suitable for observing ferrofluid distribution in plain organization, but was not suitable for observing ferrofluid distribution in complicate organization.

AB - Nano Drug Delivery System (nano-DDS) is a new medical technology. We studied medical use used by about 7 [nm] ferromagnetic fluids. We searched good energy condition offerrofluid contrast medium radiograph image used by SPring-8 synchrotron radiation X-ray. As results, in case of low photon energy 15.0 [KeV] (λ = 0.8 Å). We showedferrofluid in Acryl amid gel and taro leaf and mugwort. #1. We found Low photon energy could show vascular tissue and ferrofluid distribution respectively. In case of medium photon energy 20.0 [KeV] (λ = 0.6 Å). We observed ferrofluid in rat ear lobe and rat stomach and rat foot. #2. We found medium photon energy could see several organizations by changing exposure. In case of high photon energy 25.0 [KeV] (λ = 0.5 Å). We showed ferrofluid in chicken egg and pork. #3. We found high proton energy was suitable for observing ferrofluid distribution in plain organization, but was not suitable for observing ferrofluid distribution in complicate organization.

UR - http://www.scopus.com/inward/record.url?scp=52649128314&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=52649128314&partnerID=8YFLogxK

U2 - 10.1109/ICICIC.2008.353

DO - 10.1109/ICICIC.2008.353

M3 - Conference contribution

AN - SCOPUS:52649128314

SN - 9780769531618

T3 - 3rd International Conference on Innovative Computing Information and Control, ICICIC'08

BT - 3rd International Conference on Innovative Computing Information and Control, ICICIC'08

ER -