Micro-isolation valve for fuel tank array

Koji Takahashi, Kunihito Nagayama, Tetsuo Yasaka, Tanemasa Asano

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Isolation valve system for low-cost liquid tank array is designed and demonstrated. This valve is normally closed and opens only once for liquid injection. This array system can supply precise amount of liquid at each operation as many times as the number of tanks. In order to tolerate the ambient high pressure and to accomplish the perfect injection, a large and thick membrane is fabricated and tested as valve. Without any special structure, our valves are found to open just by applying low AC voltage to a pair of electrodes that are apart from each other by tens of micrometers. Dielectric breakdown and pressure increase inside tank are found to work effectively to form a large hole.

Original languageEnglish
Title of host publicationASME International Mechanical Engineering Congress and Exposition, Proceedings
Pages2845-2850
Number of pages6
Volume2
Publication statusPublished - 2001
Event2001 ASME International Mechanical Engineering Congress and Exposition - New York, NY, United States
Duration: Nov 11 2001Nov 16 2001

Other

Other2001 ASME International Mechanical Engineering Congress and Exposition
CountryUnited States
CityNew York, NY
Period11/11/0111/16/01

Fingerprint

Fuel tanks
Liquids
Electric breakdown
Membranes
Electrodes
Electric potential
Costs

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Takahashi, K., Nagayama, K., Yasaka, T., & Asano, T. (2001). Micro-isolation valve for fuel tank array. In ASME International Mechanical Engineering Congress and Exposition, Proceedings (Vol. 2, pp. 2845-2850)

Micro-isolation valve for fuel tank array. / Takahashi, Koji; Nagayama, Kunihito; Yasaka, Tetsuo; Asano, Tanemasa.

ASME International Mechanical Engineering Congress and Exposition, Proceedings. Vol. 2 2001. p. 2845-2850.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Takahashi, K, Nagayama, K, Yasaka, T & Asano, T 2001, Micro-isolation valve for fuel tank array. in ASME International Mechanical Engineering Congress and Exposition, Proceedings. vol. 2, pp. 2845-2850, 2001 ASME International Mechanical Engineering Congress and Exposition, New York, NY, United States, 11/11/01.
Takahashi K, Nagayama K, Yasaka T, Asano T. Micro-isolation valve for fuel tank array. In ASME International Mechanical Engineering Congress and Exposition, Proceedings. Vol. 2. 2001. p. 2845-2850
Takahashi, Koji ; Nagayama, Kunihito ; Yasaka, Tetsuo ; Asano, Tanemasa. / Micro-isolation valve for fuel tank array. ASME International Mechanical Engineering Congress and Exposition, Proceedings. Vol. 2 2001. pp. 2845-2850
@inproceedings{c2e464117ae7436ca63fefbbae76ad97,
title = "Micro-isolation valve for fuel tank array",
abstract = "Isolation valve system for low-cost liquid tank array is designed and demonstrated. This valve is normally closed and opens only once for liquid injection. This array system can supply precise amount of liquid at each operation as many times as the number of tanks. In order to tolerate the ambient high pressure and to accomplish the perfect injection, a large and thick membrane is fabricated and tested as valve. Without any special structure, our valves are found to open just by applying low AC voltage to a pair of electrodes that are apart from each other by tens of micrometers. Dielectric breakdown and pressure increase inside tank are found to work effectively to form a large hole.",
author = "Koji Takahashi and Kunihito Nagayama and Tetsuo Yasaka and Tanemasa Asano",
year = "2001",
language = "English",
volume = "2",
pages = "2845--2850",
booktitle = "ASME International Mechanical Engineering Congress and Exposition, Proceedings",

}

TY - GEN

T1 - Micro-isolation valve for fuel tank array

AU - Takahashi, Koji

AU - Nagayama, Kunihito

AU - Yasaka, Tetsuo

AU - Asano, Tanemasa

PY - 2001

Y1 - 2001

N2 - Isolation valve system for low-cost liquid tank array is designed and demonstrated. This valve is normally closed and opens only once for liquid injection. This array system can supply precise amount of liquid at each operation as many times as the number of tanks. In order to tolerate the ambient high pressure and to accomplish the perfect injection, a large and thick membrane is fabricated and tested as valve. Without any special structure, our valves are found to open just by applying low AC voltage to a pair of electrodes that are apart from each other by tens of micrometers. Dielectric breakdown and pressure increase inside tank are found to work effectively to form a large hole.

AB - Isolation valve system for low-cost liquid tank array is designed and demonstrated. This valve is normally closed and opens only once for liquid injection. This array system can supply precise amount of liquid at each operation as many times as the number of tanks. In order to tolerate the ambient high pressure and to accomplish the perfect injection, a large and thick membrane is fabricated and tested as valve. Without any special structure, our valves are found to open just by applying low AC voltage to a pair of electrodes that are apart from each other by tens of micrometers. Dielectric breakdown and pressure increase inside tank are found to work effectively to form a large hole.

UR - http://www.scopus.com/inward/record.url?scp=1542620922&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1542620922&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:1542620922

VL - 2

SP - 2845

EP - 2850

BT - ASME International Mechanical Engineering Congress and Exposition, Proceedings