TY - JOUR
T1 - Microfluidic inverted flow of ternary water/hydrophilic/ hydrophobic organic solvent solution in a Y-type microchannel and a proposal of the response microfluidic analysis through the experiment
AU - Yamawaki, Bun
AU - Mori, Ryuki
AU - Tsukagoshi, Kazuhiko
AU - Tsuchiya, Katsumi
AU - Yamashita, Kenichi
AU - Murata, Masaharu
N1 - Publisher Copyright:
© 2019 The Japan Society for Analytical Chemistry.
PY - 2019
Y1 - 2019
N2 - Two solutions that are individually fed at the same flow rate into two separate microchannels of a microchip, combine to form a single channel (a Y-type microchannel). This flow is either parallel for immiscible solutions or initially parallel, but then becomes homogeneous through diffusion, for miscible solutions. However, a new type of microfluidic behavior in a Y-type microchannel that was neither parallel nor homogeneous flow has been observed using, for example, water/ acetonitrile (3:4.5, v/v) and acetonitrile/ethyl acetate (3.5:4, v/v) mixed solutions. Each mixed solution was marked with distinctive dyes and delivered at the same flow rate into a Y-type microchannel under laminar flow conditions. In the single channel, the two phases were initially observed to flow in parallel, but then apparently swapped to flow on the opposite wall while retaining parallel flow with a slight change in the components of the two phases. We have named this type of laminar flow "microfluidic inverted flow" for ternary water/hydrophilic/hydrophobic organic solvent mixed solutions. The inverted flow of a ternary water/acetonitrile/ethyl acetate system was examined in detail under various flow conditions. We also proposed a concept of response microfluidic analysis based on such microfluidic inverted flow.
AB - Two solutions that are individually fed at the same flow rate into two separate microchannels of a microchip, combine to form a single channel (a Y-type microchannel). This flow is either parallel for immiscible solutions or initially parallel, but then becomes homogeneous through diffusion, for miscible solutions. However, a new type of microfluidic behavior in a Y-type microchannel that was neither parallel nor homogeneous flow has been observed using, for example, water/ acetonitrile (3:4.5, v/v) and acetonitrile/ethyl acetate (3.5:4, v/v) mixed solutions. Each mixed solution was marked with distinctive dyes and delivered at the same flow rate into a Y-type microchannel under laminar flow conditions. In the single channel, the two phases were initially observed to flow in parallel, but then apparently swapped to flow on the opposite wall while retaining parallel flow with a slight change in the components of the two phases. We have named this type of laminar flow "microfluidic inverted flow" for ternary water/hydrophilic/hydrophobic organic solvent mixed solutions. The inverted flow of a ternary water/acetonitrile/ethyl acetate system was examined in detail under various flow conditions. We also proposed a concept of response microfluidic analysis based on such microfluidic inverted flow.
UR - http://www.scopus.com/inward/record.url?scp=85062710209&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85062710209&partnerID=8YFLogxK
U2 - 10.2116/analsci.18P393
DO - 10.2116/analsci.18P393
M3 - Article
C2 - 30318490
AN - SCOPUS:85062710209
SN - 0910-6340
VL - 35
SP - 249
EP - 256
JO - Analytical Sciences
JF - Analytical Sciences
IS - 3
ER -