T1 - Microfluidic polymer chip with an embedded ion-selective electrode detector for nitrate-ion assay in environmental samples
AU - Masadome, Takashi
AU - Nakamura, Kazuki
AU - Iijima, Daisuke
AU - Horiuchi, Osamu
AU - Tossanaitada, Benjaporn
AU - Wakida, Shin ichi
AU - Imato, Toshihiko
N1 - Copyright:
Copyright 2019 Elsevier B.V., All rights reserved.
PY - 2010/4
Y1 - 2010/4
N2 - A nitrate ion-selective electrode (NO 3 - - ISE) has been developed based on tetradodecylammonium bromide as an anion exchanger and 2-nitrophenyl octyl ether as a plasticizer. The NO 3 - - ISE shows an almost Nernstian response to nitrate ion over a concentration range between 1.0 × 10 -6 and 1.0 × 10 -1 M, with an anionic slope of -57.7 ± 0.7 mV/decade. The selectivity coefficients of the NO 3 - - ISE for nitrate ion against chloride and sulfate were obtained. A microfluidic polymer chip was fabricated using polystyrene plates and stainless-steel wires as a template for the channel. The microfluidic polymer chip is composed of a mixing chip and a NO 3 - - ISE detector chip. The microfluidic polymer chip, integrated with a NO 3 - - ISE detector consisting of the NO 3 - - ISE and a Na + -ISE as a reference electrode, showed an almost Nernstian response to nitrate ion over a concentration range between 1.0 × 10 -5 and 1.0 × 10 -1 M, with an anionic slope of -54.3 ± 1.3 mV/decade. The microfluidic polymer chip was then applied to the determination of nitrate ion in environmental water samples, such as a tap water, a well-water sample and water for agricultural use. 2010
AB - A nitrate ion-selective electrode (NO 3 - - ISE) has been developed based on tetradodecylammonium bromide as an anion exchanger and 2-nitrophenyl octyl ether as a plasticizer. The NO 3 - - ISE shows an almost Nernstian response to nitrate ion over a concentration range between 1.0 × 10 -6 and 1.0 × 10 -1 M, with an anionic slope of -57.7 ± 0.7 mV/decade. The selectivity coefficients of the NO 3 - - ISE for nitrate ion against chloride and sulfate were obtained. A microfluidic polymer chip was fabricated using polystyrene plates and stainless-steel wires as a template for the channel. The microfluidic polymer chip is composed of a mixing chip and a NO 3 - - ISE detector chip. The microfluidic polymer chip, integrated with a NO 3 - - ISE detector consisting of the NO 3 - - ISE and a Na + -ISE as a reference electrode, showed an almost Nernstian response to nitrate ion over a concentration range between 1.0 × 10 -5 and 1.0 × 10 -1 M, with an anionic slope of -54.3 ± 1.3 mV/decade. The microfluidic polymer chip was then applied to the determination of nitrate ion in environmental water samples, such as a tap water, a well-water sample and water for agricultural use. 2010
UR - http://www.scopus.com/inward/record.url?scp=77953583240&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77953583240&partnerID=8YFLogxK
U2 - 10.2116/analsci.26.417
DO - 10.2116/analsci.26.417
M3 - Article
C2 - 20410562
AN - SCOPUS:77953583240
VL - 26
SP - 417
EP - 423
JO - Analytical Sciences
JF - Analytical Sciences
SN - 0910-6340
IS - 4
ER -