Microfluidic Separation of Redox Reactions for Coulometry Based on Metallization at the Mixed Potential

Kazuhiro Ikemoto, Takafumi Seki, Shohei Kimura, Yui Nakaoka, Shinnosuke Tsuchiya, Fumihiro Sassa, Masatoshi Yokokawa, Hiroaki Suzuki

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Coulometric detection of an analyte in a solution at nanoliter scale was conducted by having redox reactions proceed simultaneously on a platinum electrode. The analyte was oxidized on a part of the electrode in one flow channel and silver was deposited on an array of circular microelectrodes formed in another flow channel at a mixed potential. Coulometric determination of the deposited silver showed a steep change in the generated charge as a result of the complete oxidation of silver. The short measurement time after the start of the coulometry suppressed the increase in background charge, resulting in significant lowering of the detection limit. The lower detection limit for H2O2 was 30 nM (3σ). To improve selectivity and minimize the influence of coexisting interferents, the shifting of the mixed potential, application of a permselective membrane, and electrochemical elimination of the interferents were effective modifications.

Original languageEnglish
Pages (from-to)9427-9434
Number of pages8
JournalAnalytical Chemistry
Volume88
Issue number19
DOIs
Publication statusPublished - Oct 4 2016
Externally publishedYes

Fingerprint

Coulometers
Redox reactions
Metallizing
Silver
Microfluidics
Channel flow
Permselective membranes
Electrodes
Microelectrodes
Platinum
Time measurement
Oxidation

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Cite this

Microfluidic Separation of Redox Reactions for Coulometry Based on Metallization at the Mixed Potential. / Ikemoto, Kazuhiro; Seki, Takafumi; Kimura, Shohei; Nakaoka, Yui; Tsuchiya, Shinnosuke; Sassa, Fumihiro; Yokokawa, Masatoshi; Suzuki, Hiroaki.

In: Analytical Chemistry, Vol. 88, No. 19, 04.10.2016, p. 9427-9434.

Research output: Contribution to journalArticle

Ikemoto, K, Seki, T, Kimura, S, Nakaoka, Y, Tsuchiya, S, Sassa, F, Yokokawa, M & Suzuki, H 2016, 'Microfluidic Separation of Redox Reactions for Coulometry Based on Metallization at the Mixed Potential', Analytical Chemistry, vol. 88, no. 19, pp. 9427-9434. https://doi.org/10.1021/acs.analchem.6b01234
Ikemoto, Kazuhiro ; Seki, Takafumi ; Kimura, Shohei ; Nakaoka, Yui ; Tsuchiya, Shinnosuke ; Sassa, Fumihiro ; Yokokawa, Masatoshi ; Suzuki, Hiroaki. / Microfluidic Separation of Redox Reactions for Coulometry Based on Metallization at the Mixed Potential. In: Analytical Chemistry. 2016 ; Vol. 88, No. 19. pp. 9427-9434.
@article{bfdedeaee02d4c889f8bb8f68fce15db,
title = "Microfluidic Separation of Redox Reactions for Coulometry Based on Metallization at the Mixed Potential",
abstract = "Coulometric detection of an analyte in a solution at nanoliter scale was conducted by having redox reactions proceed simultaneously on a platinum electrode. The analyte was oxidized on a part of the electrode in one flow channel and silver was deposited on an array of circular microelectrodes formed in another flow channel at a mixed potential. Coulometric determination of the deposited silver showed a steep change in the generated charge as a result of the complete oxidation of silver. The short measurement time after the start of the coulometry suppressed the increase in background charge, resulting in significant lowering of the detection limit. The lower detection limit for H2O2 was 30 nM (3σ). To improve selectivity and minimize the influence of coexisting interferents, the shifting of the mixed potential, application of a permselective membrane, and electrochemical elimination of the interferents were effective modifications.",
author = "Kazuhiro Ikemoto and Takafumi Seki and Shohei Kimura and Yui Nakaoka and Shinnosuke Tsuchiya and Fumihiro Sassa and Masatoshi Yokokawa and Hiroaki Suzuki",
year = "2016",
month = "10",
day = "4",
doi = "10.1021/acs.analchem.6b01234",
language = "English",
volume = "88",
pages = "9427--9434",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "19",

}

TY - JOUR

T1 - Microfluidic Separation of Redox Reactions for Coulometry Based on Metallization at the Mixed Potential

AU - Ikemoto, Kazuhiro

AU - Seki, Takafumi

AU - Kimura, Shohei

AU - Nakaoka, Yui

AU - Tsuchiya, Shinnosuke

AU - Sassa, Fumihiro

AU - Yokokawa, Masatoshi

AU - Suzuki, Hiroaki

PY - 2016/10/4

Y1 - 2016/10/4

N2 - Coulometric detection of an analyte in a solution at nanoliter scale was conducted by having redox reactions proceed simultaneously on a platinum electrode. The analyte was oxidized on a part of the electrode in one flow channel and silver was deposited on an array of circular microelectrodes formed in another flow channel at a mixed potential. Coulometric determination of the deposited silver showed a steep change in the generated charge as a result of the complete oxidation of silver. The short measurement time after the start of the coulometry suppressed the increase in background charge, resulting in significant lowering of the detection limit. The lower detection limit for H2O2 was 30 nM (3σ). To improve selectivity and minimize the influence of coexisting interferents, the shifting of the mixed potential, application of a permselective membrane, and electrochemical elimination of the interferents were effective modifications.

AB - Coulometric detection of an analyte in a solution at nanoliter scale was conducted by having redox reactions proceed simultaneously on a platinum electrode. The analyte was oxidized on a part of the electrode in one flow channel and silver was deposited on an array of circular microelectrodes formed in another flow channel at a mixed potential. Coulometric determination of the deposited silver showed a steep change in the generated charge as a result of the complete oxidation of silver. The short measurement time after the start of the coulometry suppressed the increase in background charge, resulting in significant lowering of the detection limit. The lower detection limit for H2O2 was 30 nM (3σ). To improve selectivity and minimize the influence of coexisting interferents, the shifting of the mixed potential, application of a permselective membrane, and electrochemical elimination of the interferents were effective modifications.

UR - http://www.scopus.com/inward/record.url?scp=84989936467&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84989936467&partnerID=8YFLogxK

U2 - 10.1021/acs.analchem.6b01234

DO - 10.1021/acs.analchem.6b01234

M3 - Article

AN - SCOPUS:84989936467

VL - 88

SP - 9427

EP - 9434

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 19

ER -