Mine ventilation analysis and tracer gas test in Xing Fu colliery

Translated title of the contribution: Mine ventilation analysis and tracer gas test in Xing Fu colliery

Xiaoming Zhang, Yanwei Huo, Yongjun Wang, Arif Widiatmojo, Kyuro Sasaki

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This study analyzed and evaluated the ventilation status in Xing Fu coal mine. Using the MIVENA[1], the study simulated the ventilation system and provided an efficient mine optimization plan based on the data measured on site. For the further analysis of the problems in ventilation network, the study successfully conducted a tracer gas experiment, obtained the results expected and analyzed the preliminary experimental results. The study provides reliable information and reference materials for mine ventilation management.

Original languageChinese
Pages (from-to)859-862
Number of pages4
JournalLiaoning Gongcheng Jishu Daxue Xuebao (Ziran Kexue Ban)/Journal of Liaoning Technical University (Natural Science Edition)
Volume31
Issue number6
Publication statusPublished - Dec 1 2012

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Safety, Risk, Reliability and Quality
  • Geotechnical Engineering and Engineering Geology

Cite this