TY - JOUR
T1 - Miniaturized ternary deep eutectic solvent-based matrix solid-phase dispersion
T2 - A green sample preparation method for the determination of chlorophenols in river sediment
AU - El-Deen, Asmaa Kamal
AU - Shimizu, Kuniyoshi
N1 - Publisher Copyright:
© 2022 Wiley-VCH GmbH.
PY - 2022
Y1 - 2022
N2 - New ternary deep eutectic solvents were prepared and applied as efficient green dispersing solvents in miniaturized matrix solid-phase dispersion to extract chlorophenols from river sediments for the first time. High-performance liquid chromatography coupled with a photodiode array detector was used to analyze the target analytes. The significant factors affecting the extraction were optimized as follows: dispersant (100 mg), sample (100 mg), ternary eutectic solvents (150 μl), grinding for 1 min, 450 μl of acetonitrile as the elution solvent, and vortex mixing for 20 s. Under the optimal conditions, the method exhibited excellent linearity (correlation coefficient > 0.9980), low limits of detection between 1.039–2.478 μg/g, and extraction recoveries between 93.9% and 99.2%. Furthermore, the method demonstrated excellent precision in the intra- and inter-day analysis with a relative standard deviation below 6%. When compared to conventional extraction techniques, the miniaturized matrix solid-phase dispersion considerably reduced samples and solvent usag, offering important environmental benefits. The green profile of the method was assessed using the complementary green analytical procedure index tool confirming its eco-friendship. The technique was finally employed to evaluate sediment samples from three distinct locations along the Zuibaiji River, indicating its applicability for monitoring environmental samples.
AB - New ternary deep eutectic solvents were prepared and applied as efficient green dispersing solvents in miniaturized matrix solid-phase dispersion to extract chlorophenols from river sediments for the first time. High-performance liquid chromatography coupled with a photodiode array detector was used to analyze the target analytes. The significant factors affecting the extraction were optimized as follows: dispersant (100 mg), sample (100 mg), ternary eutectic solvents (150 μl), grinding for 1 min, 450 μl of acetonitrile as the elution solvent, and vortex mixing for 20 s. Under the optimal conditions, the method exhibited excellent linearity (correlation coefficient > 0.9980), low limits of detection between 1.039–2.478 μg/g, and extraction recoveries between 93.9% and 99.2%. Furthermore, the method demonstrated excellent precision in the intra- and inter-day analysis with a relative standard deviation below 6%. When compared to conventional extraction techniques, the miniaturized matrix solid-phase dispersion considerably reduced samples and solvent usag, offering important environmental benefits. The green profile of the method was assessed using the complementary green analytical procedure index tool confirming its eco-friendship. The technique was finally employed to evaluate sediment samples from three distinct locations along the Zuibaiji River, indicating its applicability for monitoring environmental samples.
UR - http://www.scopus.com/inward/record.url?scp=85142233346&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85142233346&partnerID=8YFLogxK
U2 - 10.1002/jssc.202200717
DO - 10.1002/jssc.202200717
M3 - Article
C2 - 36367364
AN - SCOPUS:85142233346
SN - 1615-9306
JO - Journal of Separation Science
JF - Journal of Separation Science
ER -