Modification of Backgammon shape cathode and graded charge division readout method for a novel triple charge division centroid finding method

F. Javanmardi, M. Matoba, T. Sakae, A. Nohtomi, S. Budiharju, H. Murohka

Research output: Contribution to conferencePaper

Abstract

The triple charge division (TCD) centroid finding method, which uses modified pattern of Backgammon shape cathode (MBSC), is introduced for medium range length position sensitive detectors with optimum numbers of cathode segments. The Graded Charge Division (GCD) employed as a special readout method for TCD is a combination of the charge division readout and sequence grading of serial segments. Linearity prediction of TCD centroid finding and experimental results are used to find an optimum truncation of the apices of MBCS pattern central area.

Original languageEnglish
Pages544-547
Number of pages4
Publication statusPublished - Dec 1 1996
EventProceedings of the 1996 IEEE Nuclear Science Symposium. Part 1 (of 3) - Anaheim, CA, USA
Duration: Nov 2 1996Nov 9 1996

Other

OtherProceedings of the 1996 IEEE Nuclear Science Symposium. Part 1 (of 3)
CityAnaheim, CA, USA
Period11/2/9611/9/96

Fingerprint

Cathodes
Detectors

All Science Journal Classification (ASJC) codes

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

Cite this

Javanmardi, F., Matoba, M., Sakae, T., Nohtomi, A., Budiharju, S., & Murohka, H. (1996). Modification of Backgammon shape cathode and graded charge division readout method for a novel triple charge division centroid finding method. 544-547. Paper presented at Proceedings of the 1996 IEEE Nuclear Science Symposium. Part 1 (of 3), Anaheim, CA, USA, .

Modification of Backgammon shape cathode and graded charge division readout method for a novel triple charge division centroid finding method. / Javanmardi, F.; Matoba, M.; Sakae, T.; Nohtomi, A.; Budiharju, S.; Murohka, H.

1996. 544-547 Paper presented at Proceedings of the 1996 IEEE Nuclear Science Symposium. Part 1 (of 3), Anaheim, CA, USA, .

Research output: Contribution to conferencePaper

Javanmardi, F, Matoba, M, Sakae, T, Nohtomi, A, Budiharju, S & Murohka, H 1996, 'Modification of Backgammon shape cathode and graded charge division readout method for a novel triple charge division centroid finding method', Paper presented at Proceedings of the 1996 IEEE Nuclear Science Symposium. Part 1 (of 3), Anaheim, CA, USA, 11/2/96 - 11/9/96 pp. 544-547.
Javanmardi F, Matoba M, Sakae T, Nohtomi A, Budiharju S, Murohka H. Modification of Backgammon shape cathode and graded charge division readout method for a novel triple charge division centroid finding method. 1996. Paper presented at Proceedings of the 1996 IEEE Nuclear Science Symposium. Part 1 (of 3), Anaheim, CA, USA, .
Javanmardi, F. ; Matoba, M. ; Sakae, T. ; Nohtomi, A. ; Budiharju, S. ; Murohka, H. / Modification of Backgammon shape cathode and graded charge division readout method for a novel triple charge division centroid finding method. Paper presented at Proceedings of the 1996 IEEE Nuclear Science Symposium. Part 1 (of 3), Anaheim, CA, USA, .4 p.
@conference{7f5e4d52c7bd4995a77fc46ab636a29f,
title = "Modification of Backgammon shape cathode and graded charge division readout method for a novel triple charge division centroid finding method",
abstract = "The triple charge division (TCD) centroid finding method, which uses modified pattern of Backgammon shape cathode (MBSC), is introduced for medium range length position sensitive detectors with optimum numbers of cathode segments. The Graded Charge Division (GCD) employed as a special readout method for TCD is a combination of the charge division readout and sequence grading of serial segments. Linearity prediction of TCD centroid finding and experimental results are used to find an optimum truncation of the apices of MBCS pattern central area.",
author = "F. Javanmardi and M. Matoba and T. Sakae and A. Nohtomi and S. Budiharju and H. Murohka",
year = "1996",
month = "12",
day = "1",
language = "English",
pages = "544--547",
note = "Proceedings of the 1996 IEEE Nuclear Science Symposium. Part 1 (of 3) ; Conference date: 02-11-1996 Through 09-11-1996",

}

TY - CONF

T1 - Modification of Backgammon shape cathode and graded charge division readout method for a novel triple charge division centroid finding method

AU - Javanmardi, F.

AU - Matoba, M.

AU - Sakae, T.

AU - Nohtomi, A.

AU - Budiharju, S.

AU - Murohka, H.

PY - 1996/12/1

Y1 - 1996/12/1

N2 - The triple charge division (TCD) centroid finding method, which uses modified pattern of Backgammon shape cathode (MBSC), is introduced for medium range length position sensitive detectors with optimum numbers of cathode segments. The Graded Charge Division (GCD) employed as a special readout method for TCD is a combination of the charge division readout and sequence grading of serial segments. Linearity prediction of TCD centroid finding and experimental results are used to find an optimum truncation of the apices of MBCS pattern central area.

AB - The triple charge division (TCD) centroid finding method, which uses modified pattern of Backgammon shape cathode (MBSC), is introduced for medium range length position sensitive detectors with optimum numbers of cathode segments. The Graded Charge Division (GCD) employed as a special readout method for TCD is a combination of the charge division readout and sequence grading of serial segments. Linearity prediction of TCD centroid finding and experimental results are used to find an optimum truncation of the apices of MBCS pattern central area.

UR - http://www.scopus.com/inward/record.url?scp=0030358537&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030358537&partnerID=8YFLogxK

M3 - Paper

AN - SCOPUS:0030358537

SP - 544

EP - 547

ER -