Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width

Tomoko Imasaka, Totaro Imasaka

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Tetraazacrown was useful for measuring a >1.6-fs pulse in the ultraviolet region and aliphatic hydrocarbon for a >0.96-fs pulse in the far-ultraviolet region using an autocorrelator consisting of a mass spectrometer as a two-photon-response detector.

Original languageEnglish
Title of host publicationCLEO
Subtitle of host publicationScience and Innovations, CLEO_SI 2012
Publication statusPublished - Dec 1 2012
EventCLEO: Science and Innovations, CLEO_SI 2012 - San Jose, CA, United States
Duration: May 6 2012May 11 2012

Publication series

NameCLEO: Science and Innovations, CLEO_SI 2012

Other

OtherCLEO: Science and Innovations, CLEO_SI 2012
CountryUnited States
CitySan Jose, CA
Period5/6/125/11/12

Fingerprint

Mass spectrometers
Hydrocarbons
Laser pulses
Photons
Detectors
Molecules

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials

Cite this

Imasaka, T., & Imasaka, T. (2012). Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. In CLEO: Science and Innovations, CLEO_SI 2012 (CLEO: Science and Innovations, CLEO_SI 2012).

Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. / Imasaka, Tomoko; Imasaka, Totaro.

CLEO: Science and Innovations, CLEO_SI 2012. 2012. (CLEO: Science and Innovations, CLEO_SI 2012).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Imasaka, T & Imasaka, T 2012, Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. in CLEO: Science and Innovations, CLEO_SI 2012. CLEO: Science and Innovations, CLEO_SI 2012, CLEO: Science and Innovations, CLEO_SI 2012, San Jose, CA, United States, 5/6/12.
Imasaka T, Imasaka T. Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. In CLEO: Science and Innovations, CLEO_SI 2012. 2012. (CLEO: Science and Innovations, CLEO_SI 2012).
Imasaka, Tomoko ; Imasaka, Totaro. / Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. CLEO: Science and Innovations, CLEO_SI 2012. 2012. (CLEO: Science and Innovations, CLEO_SI 2012).
@inproceedings{eec6f72352434fed980320ac3fda64d1,
title = "Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width",
abstract = "Tetraazacrown was useful for measuring a >1.6-fs pulse in the ultraviolet region and aliphatic hydrocarbon for a >0.96-fs pulse in the far-ultraviolet region using an autocorrelator consisting of a mass spectrometer as a two-photon-response detector.",
author = "Tomoko Imasaka and Totaro Imasaka",
year = "2012",
month = "12",
day = "1",
language = "English",
isbn = "9781557529435",
series = "CLEO: Science and Innovations, CLEO_SI 2012",
booktitle = "CLEO",

}

TY - GEN

T1 - Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width

AU - Imasaka, Tomoko

AU - Imasaka, Totaro

PY - 2012/12/1

Y1 - 2012/12/1

N2 - Tetraazacrown was useful for measuring a >1.6-fs pulse in the ultraviolet region and aliphatic hydrocarbon for a >0.96-fs pulse in the far-ultraviolet region using an autocorrelator consisting of a mass spectrometer as a two-photon-response detector.

AB - Tetraazacrown was useful for measuring a >1.6-fs pulse in the ultraviolet region and aliphatic hydrocarbon for a >0.96-fs pulse in the far-ultraviolet region using an autocorrelator consisting of a mass spectrometer as a two-photon-response detector.

UR - http://www.scopus.com/inward/record.url?scp=84890675000&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890675000&partnerID=8YFLogxK

M3 - Conference contribution

SN - 9781557529435

T3 - CLEO: Science and Innovations, CLEO_SI 2012

BT - CLEO

ER -