Neutron Dosimetry System Using CR-39 for High-energy X-ray Radiation Therapy

Kazutoshi Yabuta, Hajime Monzen, Masaya Tamura, Takao Tsuruta, Tetsuo Itou, Akihiro Nohtomi, Yasumasa Nishimura

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Neutrons are produced during radiation treatment by megavolt X-ray energies. However, it is difficult to measure neutron dose especially just during the irradiation. Therefore, we have developed a system for measuring neutrons with the solid state track detector CR-39, which is free from the influence of the X-ray beams. The energy spectrum of the neutrons was estimated by a Monte Carlo simulation method, and the estimated neutron dose was corrected by the contribution ratio of each energy. Pit formation rates of CR-39 ranged from 2.3 x 10(-3) to 8.2 x 10(-3) for each detector studied. According to the estimated neutron energy spectrum, the energy values for calibration were 144 keV and 515keV, and the contribution ratios were approximately 40:60 for 10 MV photons and 20:70 for photons over 15 MV. Neutron doses measured in the center of a high-energy X-ray field were 0.045 mSv/Gy for a 10 MV linear accelerator and 0.85 mSv/Gy for a 20 MV linear accelerator. We successfully developed the new neutron dose measurement system using the solid track detector, CR-39. This on-time neutron measurement system allows users to measure neutron doses produced in the radiation treatment room more easily.

Original languageEnglish
Pages (from-to)139-148
Number of pages10
JournalIgaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics
Volume34
Issue number3
Publication statusPublished - Jan 1 2014

Fingerprint

X-Ray Therapy
Neutrons
Radiotherapy
X-Rays
Particle Accelerators
Photons
CR 39
Radiation
Monte Carlo Method
Calibration

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

Neutron Dosimetry System Using CR-39 for High-energy X-ray Radiation Therapy. / Yabuta, Kazutoshi; Monzen, Hajime; Tamura, Masaya; Tsuruta, Takao; Itou, Tetsuo; Nohtomi, Akihiro; Nishimura, Yasumasa.

In: Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics, Vol. 34, No. 3, 01.01.2014, p. 139-148.

Research output: Contribution to journalArticle

@article{048a3b5ffc134d9ba7a1b929a77c40e2,
title = "Neutron Dosimetry System Using CR-39 for High-energy X-ray Radiation Therapy",
abstract = "Neutrons are produced during radiation treatment by megavolt X-ray energies. However, it is difficult to measure neutron dose especially just during the irradiation. Therefore, we have developed a system for measuring neutrons with the solid state track detector CR-39, which is free from the influence of the X-ray beams. The energy spectrum of the neutrons was estimated by a Monte Carlo simulation method, and the estimated neutron dose was corrected by the contribution ratio of each energy. Pit formation rates of CR-39 ranged from 2.3 x 10(-3) to 8.2 x 10(-3) for each detector studied. According to the estimated neutron energy spectrum, the energy values for calibration were 144 keV and 515keV, and the contribution ratios were approximately 40:60 for 10 MV photons and 20:70 for photons over 15 MV. Neutron doses measured in the center of a high-energy X-ray field were 0.045 mSv/Gy for a 10 MV linear accelerator and 0.85 mSv/Gy for a 20 MV linear accelerator. We successfully developed the new neutron dose measurement system using the solid track detector, CR-39. This on-time neutron measurement system allows users to measure neutron doses produced in the radiation treatment room more easily.",
author = "Kazutoshi Yabuta and Hajime Monzen and Masaya Tamura and Takao Tsuruta and Tetsuo Itou and Akihiro Nohtomi and Yasumasa Nishimura",
year = "2014",
month = "1",
day = "1",
language = "English",
volume = "34",
pages = "139--148",
journal = "Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics",
issn = "1345-5354",
publisher = "Nihon Igaku Butsuri Gakkai",
number = "3",

}

TY - JOUR

T1 - Neutron Dosimetry System Using CR-39 for High-energy X-ray Radiation Therapy

AU - Yabuta, Kazutoshi

AU - Monzen, Hajime

AU - Tamura, Masaya

AU - Tsuruta, Takao

AU - Itou, Tetsuo

AU - Nohtomi, Akihiro

AU - Nishimura, Yasumasa

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Neutrons are produced during radiation treatment by megavolt X-ray energies. However, it is difficult to measure neutron dose especially just during the irradiation. Therefore, we have developed a system for measuring neutrons with the solid state track detector CR-39, which is free from the influence of the X-ray beams. The energy spectrum of the neutrons was estimated by a Monte Carlo simulation method, and the estimated neutron dose was corrected by the contribution ratio of each energy. Pit formation rates of CR-39 ranged from 2.3 x 10(-3) to 8.2 x 10(-3) for each detector studied. According to the estimated neutron energy spectrum, the energy values for calibration were 144 keV and 515keV, and the contribution ratios were approximately 40:60 for 10 MV photons and 20:70 for photons over 15 MV. Neutron doses measured in the center of a high-energy X-ray field were 0.045 mSv/Gy for a 10 MV linear accelerator and 0.85 mSv/Gy for a 20 MV linear accelerator. We successfully developed the new neutron dose measurement system using the solid track detector, CR-39. This on-time neutron measurement system allows users to measure neutron doses produced in the radiation treatment room more easily.

AB - Neutrons are produced during radiation treatment by megavolt X-ray energies. However, it is difficult to measure neutron dose especially just during the irradiation. Therefore, we have developed a system for measuring neutrons with the solid state track detector CR-39, which is free from the influence of the X-ray beams. The energy spectrum of the neutrons was estimated by a Monte Carlo simulation method, and the estimated neutron dose was corrected by the contribution ratio of each energy. Pit formation rates of CR-39 ranged from 2.3 x 10(-3) to 8.2 x 10(-3) for each detector studied. According to the estimated neutron energy spectrum, the energy values for calibration were 144 keV and 515keV, and the contribution ratios were approximately 40:60 for 10 MV photons and 20:70 for photons over 15 MV. Neutron doses measured in the center of a high-energy X-ray field were 0.045 mSv/Gy for a 10 MV linear accelerator and 0.85 mSv/Gy for a 20 MV linear accelerator. We successfully developed the new neutron dose measurement system using the solid track detector, CR-39. This on-time neutron measurement system allows users to measure neutron doses produced in the radiation treatment room more easily.

UR - http://www.scopus.com/inward/record.url?scp=84939801055&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84939801055&partnerID=8YFLogxK

M3 - Article

VL - 34

SP - 139

EP - 148

JO - Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics

JF - Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics

SN - 1345-5354

IS - 3

ER -