Abstract

In order to seek a magnetic shell material of low magnetic noise under magnetic shaking, fluctuations of the magnetization under the 1 kHz excitation are characterized and compared to the Barkhausen noise (BHN) under the sine-current excitation of 2 Hz. Two Co-based amorphous magnetic tapes, Metglas 2705M and 2714A, are examined. Measurements were carried out in a cylindrical magnetic shield with two identical toroidal samples to cancel the fundamental component and harmonics of the excitation voltage. Induced voltages in the frequency range less than 500 Hz were considered as fluctuation noise. A good correlation between fluctuation noise and BHN was confirmed for both samples. Metglas 2705M has high shaking efficiency but higher noise than Metglas 2714A.

Original languageEnglish
Pages (from-to)3435-3437
Number of pages3
JournalIEEE Transactions on Magnetics
Volume39
Issue number5 II
DOIs
Publication statusPublished - Sep 1 2003

Fingerprint

Magnetic shielding
magnetic shielding
shaking
Tapes
tapes
Magnetic tape
Electric potential
Magnetization
excitation
magnetic tapes
electric potential
frequency ranges
harmonics
magnetization

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Cite this

Noise Characteristics of Co-Based Amorphous Tapes to be Applied as Magnetic Shielding Shell for Magnetic Shaking. / Sasada, Ichiro; Shiokawa, Masahiro.

In: IEEE Transactions on Magnetics, Vol. 39, No. 5 II, 01.09.2003, p. 3435-3437.

Research output: Contribution to journalArticle

@article{0d1c823f560b419ebdbdd9f4ecb66a71,
title = "Noise Characteristics of Co-Based Amorphous Tapes to be Applied as Magnetic Shielding Shell for Magnetic Shaking",
abstract = "In order to seek a magnetic shell material of low magnetic noise under magnetic shaking, fluctuations of the magnetization under the 1 kHz excitation are characterized and compared to the Barkhausen noise (BHN) under the sine-current excitation of 2 Hz. Two Co-based amorphous magnetic tapes, Metglas 2705M and 2714A, are examined. Measurements were carried out in a cylindrical magnetic shield with two identical toroidal samples to cancel the fundamental component and harmonics of the excitation voltage. Induced voltages in the frequency range less than 500 Hz were considered as fluctuation noise. A good correlation between fluctuation noise and BHN was confirmed for both samples. Metglas 2705M has high shaking efficiency but higher noise than Metglas 2714A.",
author = "Ichiro Sasada and Masahiro Shiokawa",
year = "2003",
month = "9",
day = "1",
doi = "10.1109/TMAG.2003.816174",
language = "English",
volume = "39",
pages = "3435--3437",
journal = "IEEE Transactions on Magnetics",
issn = "0018-9464",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "5 II",

}

TY - JOUR

T1 - Noise Characteristics of Co-Based Amorphous Tapes to be Applied as Magnetic Shielding Shell for Magnetic Shaking

AU - Sasada, Ichiro

AU - Shiokawa, Masahiro

PY - 2003/9/1

Y1 - 2003/9/1

N2 - In order to seek a magnetic shell material of low magnetic noise under magnetic shaking, fluctuations of the magnetization under the 1 kHz excitation are characterized and compared to the Barkhausen noise (BHN) under the sine-current excitation of 2 Hz. Two Co-based amorphous magnetic tapes, Metglas 2705M and 2714A, are examined. Measurements were carried out in a cylindrical magnetic shield with two identical toroidal samples to cancel the fundamental component and harmonics of the excitation voltage. Induced voltages in the frequency range less than 500 Hz were considered as fluctuation noise. A good correlation between fluctuation noise and BHN was confirmed for both samples. Metglas 2705M has high shaking efficiency but higher noise than Metglas 2714A.

AB - In order to seek a magnetic shell material of low magnetic noise under magnetic shaking, fluctuations of the magnetization under the 1 kHz excitation are characterized and compared to the Barkhausen noise (BHN) under the sine-current excitation of 2 Hz. Two Co-based amorphous magnetic tapes, Metglas 2705M and 2714A, are examined. Measurements were carried out in a cylindrical magnetic shield with two identical toroidal samples to cancel the fundamental component and harmonics of the excitation voltage. Induced voltages in the frequency range less than 500 Hz were considered as fluctuation noise. A good correlation between fluctuation noise and BHN was confirmed for both samples. Metglas 2705M has high shaking efficiency but higher noise than Metglas 2714A.

UR - http://www.scopus.com/inward/record.url?scp=0141918468&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0141918468&partnerID=8YFLogxK

U2 - 10.1109/TMAG.2003.816174

DO - 10.1109/TMAG.2003.816174

M3 - Article

AN - SCOPUS:0141918468

VL - 39

SP - 3435

EP - 3437

JO - IEEE Transactions on Magnetics

JF - IEEE Transactions on Magnetics

SN - 0018-9464

IS - 5 II

ER -