On-chip dual arm microrobot for cell manipulations by magnetically driven microtools

Masaya Hagiwara, Tomohiro Kawahara, Yoko Yamanishi, Fumihito Arai

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This paper presents the innovative driving method of on-chip dual arm microrobots to achieve precise cell manipulations. The positioning accuracy in the new driving method improves 5 times higher and the response speed becomes 10 times quicker against the driving stage than in the conventional method. Commercially available permanent magnets are used to actuate the microrobots owing to the considerably stronger magnetic fields than electromagnetic coil to enforce the high power output. A swine oocyte, which is relatively large cell and require stronger force amount to manipulate, have been precisely handled and cut in microfluidic chip.

Original languageEnglish
Title of host publication14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010
Pages238-240
Number of pages3
Publication statusPublished - Dec 1 2010
Event14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010 - Groningen, Netherlands
Duration: Oct 3 2010Oct 7 2010

Publication series

Name14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010
Volume1

Other

Other14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010
CountryNetherlands
CityGroningen
Period10/3/1010/7/10

Fingerprint

Microfluidics
Permanent magnets
Magnetic fields

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering

Cite this

Hagiwara, M., Kawahara, T., Yamanishi, Y., & Arai, F. (2010). On-chip dual arm microrobot for cell manipulations by magnetically driven microtools. In 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010 (pp. 238-240). (14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010; Vol. 1).

On-chip dual arm microrobot for cell manipulations by magnetically driven microtools. / Hagiwara, Masaya; Kawahara, Tomohiro; Yamanishi, Yoko; Arai, Fumihito.

14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010. 2010. p. 238-240 (14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010; Vol. 1).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Hagiwara, M, Kawahara, T, Yamanishi, Y & Arai, F 2010, On-chip dual arm microrobot for cell manipulations by magnetically driven microtools. in 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010. 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010, vol. 1, pp. 238-240, 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010, Groningen, Netherlands, 10/3/10.
Hagiwara M, Kawahara T, Yamanishi Y, Arai F. On-chip dual arm microrobot for cell manipulations by magnetically driven microtools. In 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010. 2010. p. 238-240. (14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010).
Hagiwara, Masaya ; Kawahara, Tomohiro ; Yamanishi, Yoko ; Arai, Fumihito. / On-chip dual arm microrobot for cell manipulations by magnetically driven microtools. 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010. 2010. pp. 238-240 (14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010).
@inproceedings{51cfec73521048d387f68bbca038c271,
title = "On-chip dual arm microrobot for cell manipulations by magnetically driven microtools",
abstract = "This paper presents the innovative driving method of on-chip dual arm microrobots to achieve precise cell manipulations. The positioning accuracy in the new driving method improves 5 times higher and the response speed becomes 10 times quicker against the driving stage than in the conventional method. Commercially available permanent magnets are used to actuate the microrobots owing to the considerably stronger magnetic fields than electromagnetic coil to enforce the high power output. A swine oocyte, which is relatively large cell and require stronger force amount to manipulate, have been precisely handled and cut in microfluidic chip.",
author = "Masaya Hagiwara and Tomohiro Kawahara and Yoko Yamanishi and Fumihito Arai",
year = "2010",
month = "12",
day = "1",
language = "English",
isbn = "9781618390622",
series = "14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010",
pages = "238--240",
booktitle = "14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010",

}

TY - GEN

T1 - On-chip dual arm microrobot for cell manipulations by magnetically driven microtools

AU - Hagiwara, Masaya

AU - Kawahara, Tomohiro

AU - Yamanishi, Yoko

AU - Arai, Fumihito

PY - 2010/12/1

Y1 - 2010/12/1

N2 - This paper presents the innovative driving method of on-chip dual arm microrobots to achieve precise cell manipulations. The positioning accuracy in the new driving method improves 5 times higher and the response speed becomes 10 times quicker against the driving stage than in the conventional method. Commercially available permanent magnets are used to actuate the microrobots owing to the considerably stronger magnetic fields than electromagnetic coil to enforce the high power output. A swine oocyte, which is relatively large cell and require stronger force amount to manipulate, have been precisely handled and cut in microfluidic chip.

AB - This paper presents the innovative driving method of on-chip dual arm microrobots to achieve precise cell manipulations. The positioning accuracy in the new driving method improves 5 times higher and the response speed becomes 10 times quicker against the driving stage than in the conventional method. Commercially available permanent magnets are used to actuate the microrobots owing to the considerably stronger magnetic fields than electromagnetic coil to enforce the high power output. A swine oocyte, which is relatively large cell and require stronger force amount to manipulate, have been precisely handled and cut in microfluidic chip.

UR - http://www.scopus.com/inward/record.url?scp=84884309955&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84884309955&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84884309955

SN - 9781618390622

T3 - 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010

SP - 238

EP - 240

BT - 14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010

ER -