Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease

Yuzo Yamasaki, Satoshi Kawanami, Takeshi Kamitani, Koji Sagiyama, Seitaro Shin, Takuya Hino, Hazumu Nagata, Hidetake Yabuuchi, Michinobu Nagao, Hiroshi Honda

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

To investigate the performance of second-generation 320-row computed tomographic (CT) angiography (CTA) in detecting coronary arteries and identify factors influencing visibility of the coronary arteries in infants with complex congenital heart disease (CHD). Data of 60 infants (aged 0–2 years, median 2 months) with complex CHD who underwent examination using 320-row CTA with low-dose prospective electrocardiogram-triggered volume target scanning were reviewed. The coronary arteries of each infant were assessed using a 0–4-point scoring system based on the number of coronary segments with a visible course. Clinical parameters, the CT value in the ascending aorta, image noise, and the radiation dose were subjected to univariate and multivariate analyses. The mean coronary score for all examinations was 2.6 ± 1.5 points. The mean attenuation in the ascending aorta was 306.7 ± 66.2 HU and the mean standard deviation was 21.7 ± 4.4. The mean effective radiation dose was 1.27 ± 0.39 mSv. Multivariate regression analysis showed significant correlations between coronary score and body weight (p < 0.05) and between coronary score and the CT value in the ascending aorta (p < 0.02). Second-generation 320-row CTA with prospective electrocardiogram-triggered volume target scanning and hybrid iterative reconstruction allows good visibility of the coronary arteries in infants with complex CHD. Body weight and the CT value in the ascending aorta are important factors influencing the visibility of the coronary arteries in infants.

Original languageEnglish
Pages (from-to)1485-1491
Number of pages7
JournalInternational Journal of Cardiovascular Imaging
Volume34
Issue number9
DOIs
Publication statusPublished - Sep 1 2018

Fingerprint

Heart Diseases
Coronary Vessels
Angiography
Aorta
Electrocardiography
Multivariate Analysis
Body Weight
Radiation
Regression Analysis
Computed Tomography Angiography

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Cite this

Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease. / Yamasaki, Yuzo; Kawanami, Satoshi; Kamitani, Takeshi; Sagiyama, Koji; Shin, Seitaro; Hino, Takuya; Nagata, Hazumu; Yabuuchi, Hidetake; Nagao, Michinobu; Honda, Hiroshi.

In: International Journal of Cardiovascular Imaging, Vol. 34, No. 9, 01.09.2018, p. 1485-1491.

Research output: Contribution to journalArticle

@article{a5692c2e608843daa5c250975aac3554,
title = "Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease",
abstract = "To investigate the performance of second-generation 320-row computed tomographic (CT) angiography (CTA) in detecting coronary arteries and identify factors influencing visibility of the coronary arteries in infants with complex congenital heart disease (CHD). Data of 60 infants (aged 0–2 years, median 2 months) with complex CHD who underwent examination using 320-row CTA with low-dose prospective electrocardiogram-triggered volume target scanning were reviewed. The coronary arteries of each infant were assessed using a 0–4-point scoring system based on the number of coronary segments with a visible course. Clinical parameters, the CT value in the ascending aorta, image noise, and the radiation dose were subjected to univariate and multivariate analyses. The mean coronary score for all examinations was 2.6 ± 1.5 points. The mean attenuation in the ascending aorta was 306.7 ± 66.2 HU and the mean standard deviation was 21.7 ± 4.4. The mean effective radiation dose was 1.27 ± 0.39 mSv. Multivariate regression analysis showed significant correlations between coronary score and body weight (p < 0.05) and between coronary score and the CT value in the ascending aorta (p < 0.02). Second-generation 320-row CTA with prospective electrocardiogram-triggered volume target scanning and hybrid iterative reconstruction allows good visibility of the coronary arteries in infants with complex CHD. Body weight and the CT value in the ascending aorta are important factors influencing the visibility of the coronary arteries in infants.",
author = "Yuzo Yamasaki and Satoshi Kawanami and Takeshi Kamitani and Koji Sagiyama and Seitaro Shin and Takuya Hino and Hazumu Nagata and Hidetake Yabuuchi and Michinobu Nagao and Hiroshi Honda",
year = "2018",
month = "9",
day = "1",
doi = "10.1007/s10554-018-1363-8",
language = "English",
volume = "34",
pages = "1485--1491",
journal = "International Journal of Cardiovascular Imaging",
issn = "1569-5794",
publisher = "Springer Netherlands",
number = "9",

}

TY - JOUR

T1 - Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease

AU - Yamasaki, Yuzo

AU - Kawanami, Satoshi

AU - Kamitani, Takeshi

AU - Sagiyama, Koji

AU - Shin, Seitaro

AU - Hino, Takuya

AU - Nagata, Hazumu

AU - Yabuuchi, Hidetake

AU - Nagao, Michinobu

AU - Honda, Hiroshi

PY - 2018/9/1

Y1 - 2018/9/1

N2 - To investigate the performance of second-generation 320-row computed tomographic (CT) angiography (CTA) in detecting coronary arteries and identify factors influencing visibility of the coronary arteries in infants with complex congenital heart disease (CHD). Data of 60 infants (aged 0–2 years, median 2 months) with complex CHD who underwent examination using 320-row CTA with low-dose prospective electrocardiogram-triggered volume target scanning were reviewed. The coronary arteries of each infant were assessed using a 0–4-point scoring system based on the number of coronary segments with a visible course. Clinical parameters, the CT value in the ascending aorta, image noise, and the radiation dose were subjected to univariate and multivariate analyses. The mean coronary score for all examinations was 2.6 ± 1.5 points. The mean attenuation in the ascending aorta was 306.7 ± 66.2 HU and the mean standard deviation was 21.7 ± 4.4. The mean effective radiation dose was 1.27 ± 0.39 mSv. Multivariate regression analysis showed significant correlations between coronary score and body weight (p < 0.05) and between coronary score and the CT value in the ascending aorta (p < 0.02). Second-generation 320-row CTA with prospective electrocardiogram-triggered volume target scanning and hybrid iterative reconstruction allows good visibility of the coronary arteries in infants with complex CHD. Body weight and the CT value in the ascending aorta are important factors influencing the visibility of the coronary arteries in infants.

AB - To investigate the performance of second-generation 320-row computed tomographic (CT) angiography (CTA) in detecting coronary arteries and identify factors influencing visibility of the coronary arteries in infants with complex congenital heart disease (CHD). Data of 60 infants (aged 0–2 years, median 2 months) with complex CHD who underwent examination using 320-row CTA with low-dose prospective electrocardiogram-triggered volume target scanning were reviewed. The coronary arteries of each infant were assessed using a 0–4-point scoring system based on the number of coronary segments with a visible course. Clinical parameters, the CT value in the ascending aorta, image noise, and the radiation dose were subjected to univariate and multivariate analyses. The mean coronary score for all examinations was 2.6 ± 1.5 points. The mean attenuation in the ascending aorta was 306.7 ± 66.2 HU and the mean standard deviation was 21.7 ± 4.4. The mean effective radiation dose was 1.27 ± 0.39 mSv. Multivariate regression analysis showed significant correlations between coronary score and body weight (p < 0.05) and between coronary score and the CT value in the ascending aorta (p < 0.02). Second-generation 320-row CTA with prospective electrocardiogram-triggered volume target scanning and hybrid iterative reconstruction allows good visibility of the coronary arteries in infants with complex CHD. Body weight and the CT value in the ascending aorta are important factors influencing the visibility of the coronary arteries in infants.

UR - http://www.scopus.com/inward/record.url?scp=85046479153&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85046479153&partnerID=8YFLogxK

U2 - 10.1007/s10554-018-1363-8

DO - 10.1007/s10554-018-1363-8

M3 - Article

VL - 34

SP - 1485

EP - 1491

JO - International Journal of Cardiovascular Imaging

JF - International Journal of Cardiovascular Imaging

SN - 1569-5794

IS - 9

ER -